US hospital quality rankings and ratings use disparate methodologies and are weakly correlated. This causes confusion for patients and hospital quality staff. At the authors’ institution, a Composite Hospital Quality Index (CHQI) was developed to combine hospital quality ratings. This approach is described and a calculator is shared here for other health systems to explore their performance. Among the US News and World Report Top 50 Hospitals, hospital-specific numeric summary scores were aggregated from the 2021 Centers for Medicare and Medicaid Services (CMS) Hospital Overall Star Rating, the Spring 2021 Leapfrog Safety Grade, and the April 2021 Hospital Consumer Assessment of Healthcare Providers and Systems Star Rating. The CHQI is the hospital-specific sum of the national percentile-rankings across these 3 ratings. In this example, mean (SD) percentiles were as follows: CMS Stars 74 (19), Hospital Consumer Assessment of Healthcare Providers and Systems 63 (19), Leapfrog 65 (24), with mean (SD) CHQI of 202 (49). The CHQI is used at the authors’ institution to identify improvement opportunities and ensure that high-quality care is delivered across the health system.
The association of acute COVID‐19 infection with Patient Safety Indicator‐12 events in a multisite healthcare system
AbstractBackgroundPatient Safety Indicator (PSI)‐12, a hospital quality measure designed by Agency for Healthcare Research and Quality (AHRQ) to capture potentially preventable adverse events, captures perioperative venous thromboembolism (VTE). It is unclear how COVID‐19 has affected PSI‐12 performance.ObjectiveWe sought to compare the cumulative incidence of PSI‐12 in patients with and without acute COVID‐19 infection.Design, Setting, and ParticipantsThis was a retrospective cohort study including PSI‐12‐eligible events at three Mayo Clinic medical centers (4/1/2020‐10/5/2021).Exposure, Main Outcomes, and MeasuresWe compared the unadjusted rate and adjusted risk ratio (aRR) for PSI‐12 events among patients with and without COVID‐19 infection using Fisher's exact χ2 test and the AHRQ risk‐adjustment software, respectively. We summarized the clinical outcomes of COVID‐19 patients with a PSI‐12 event.ResultsOur cohort included 50,400 consecutive hospitalizations. Rates of PSI‐12 events were significantly higher among patients with acute COVID‐19 infection (8/257 [3.11%; 95% confidence interval {CI}, 1.35%–6.04%]) compared to patients without COVID‐19 (210/50,143 [0.42%; 95% CI, 0.36%–0.48%]) with a PSI‐12 event during the encounter (p < .001). The risk‐adjusted rate of PSI‐12 was significantly higher in patients with acute COVID‐19 infection (1.50% vs. 0.38%; aRR, 3.90; 95% CI, 2.12–7.17; p < .001). All COVID‐19 patients with PSI‐12 events had severe disease and 4 died. The most common procedure was tracheostomy (75%); the mean (SD) days from surgical procedure to VTE were 0.12 (7.32) days.ConclusionPatients with acute COVID‐19 infection are at higher risk for PSI‐12. The present definition of PSI‐12 does not account for COVID‐19. This may impact hospitals' quality performance if COVID‐19 infection is not accounted for by exclusion or risk adjustment.
Nine-year prospective efficacy and safety of brain-responsive neurostimulation for focal epilepsy
Summary Objective A prospective multicenter phase III trial was undertaken to evaluate the performance and tolerability in the epilepsy monitoring unit ( EMU ) of an investigational wearable surface electromyographic ( sEMG ) monitoring system for the detection of generalized tonic–clonic seizures ( GTCSs ). Methods One hundred ninety‐nine patients with a history of GTCSs who were admitted to the EMU in 11 level IV epilepsy centers for clinically indicated video‐electroencephalographic monitoring also received sEMG monitoring with a wearable device that was worn on the arm over the biceps muscle. All recorded sEMG data were processed at a central site using a previously developed detection algorithm. Detected GTCSs were compared to events verified by a majority of three expert reviewers. Results For all subjects, the detection algorithm detected 35 of 46 (76%, 95% confidence interval [CI] = 0.61–0.87) of the GTCSs, with a positive predictive value ( PPV ) of 0.03 and a mean false alarm rate ( FAR ) of 2.52 per 24 h. For data recorded while the device was placed over the midline of the biceps muscle, the system detected 29 of 29 GTCSs (100%, 95% CI = 0.88–1.00), with a detection delay averaging 7.70 s, a PPV of 6.2%, and a mean FAR of 1.44 per 24 h. Mild to moderate adverse events were reported in 28% (55 of 199) of subjects and led to study withdrawal in 9% (17 of 199). These adverse events consisted mostly of skin irritation caused by the electrode patch that resolved without treatment. No serious adverse events were reported. Significance Detection of GTCSs using an sEMG monitoring device on the biceps is feasible. Proper positioning of this device is important for accuracy, and for some patients, minimizing the number of false positives may be challenging.
Brain‐responsive neurostimulation in patients with medically intractable mesial temporal lobe epilepsy
SummaryObjectiveEvaluate the seizure‐reduction response and safety of mesial temporal lobe (MTL) brain‐responsive stimulation in adults with medically intractable partial‐onset seizures of mesial temporal lobe origin.MethodsSubjects with mesial temporal lobe epilepsy (MTLE) were identified from prospective clinical trials of a brain‐responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2–6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events.ResultsThere were 111 subjects with MTLE; 72% of subjects had bilateral MTL onsets and 28% had unilateral onsets. Subjects had one to four leads placed; only two leads could be connected to the device. Seventy‐six subjects had depth leads only, 29 had both depth and strip leads, and 6 had only strip leads. The mean follow‐up was 6.1 ± (standard deviation) 2.2 years. The median percent seizure reduction was 70% (last observation carried forward). Twenty‐nine percent of subjects experienced at least one seizure‐free period of 6 months or longer, and 15% experienced at least one seizure‐free period of 1 year or longer. There was no difference in seizure reduction in subjects with and without mesial temporal sclerosis (MTS), bilateral MTL onsets, prior resection, prior intracranial monitoring, and prior vagus nerve stimulation. In addition, seizure reduction was not dependent on the location of depth leads relative to the hippocampus. The most frequent serious device‐related adverse event was soft tissue implant‐site infection (overall rate, including events categorized as device‐related, uncertain, or not device‐related: 0.03 per implant year, which is not greater than with other neurostimulation devices).SignificanceBrain‐responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including patients with unilateral or bilateral MTLE who are not candidates for temporal lobectomy or who have failed a prior MTL resection.
Brain‐responsive neurostimulation in patients with medically intractable seizures arising from eloquent and other neocortical areas
SummaryObjectiveEvaluate the seizure‐reduction response and safety of brain‐responsive stimulation in adults with medically intractable partial‐onset seizures of neocortical origin.MethodsPatients with partial seizures of neocortical origin were identified from prospective clinical trials of a brain‐responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2–6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. Additional analyses considered safety and seizure reduction according to lobe and functional area (e.g., eloquent cortex) of seizure onset.ResultsThere were 126 patients with seizures of neocortical onset. The average follow‐up was 6.1 implant years. The median percent seizure reduction was 70% in patients with frontal and parietal seizure onsets, 58% in those with temporal neocortical onsets, and 51% in those with multilobar onsets (last observation carried forward [LOCF] analysis). Twenty‐six percent of patients experienced at least one seizure‐free period of 6 months or longer and 14% experienced at least one seizure‐free period of 1 year or longer. Patients with lesions on magnetic resonance imaging (MRI; 77% reduction, LOCF) and those with normal MRI findings (45% reduction, LOCF) benefitted, although the treatment response was more robust in patients with an MRI lesion (p = 0.02, generalized estimating equation [GEE]). There were no differences in the seizure reduction in patients with and without prior epilepsy surgery or vagus nerve stimulation. Stimulation parameters used for treatment did not cause acute or chronic neurologic deficits, even in eloquent cortical areas. The rates of infection (0.017 per patient implant year) and perioperative hemorrhage (0.8%) were not greater than with other neurostimulation devices.SignificanceBrain‐responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including adults with seizures of neocortical onset, and those with onsets from eloquent cortex.
Managing Common Complex Symptomatic Epilepsies: Tumors and Trauma
Purpose. To investigate EEG and SPECT in the surgical outcome of patients with normal MRI (nonlesional) and extratemporal lobe epilepsy. Methods. We retrospectively identified 41 consecutive patients with nonlesional extratemporal epilepsy who underwent epilepsy surgery between 1997 and 2007. The history, noninvasive diagnostic studies (scalp EEG, MRI, and SPECT) and intracranial EEG (iEEG) monitoring was reviewed. Scalp and iEEG ictal onset patterns were defined. The association of preoperative studies and postoperative seizure freedom was analyzed using Kaplan-Meier analysis, log-rank test, and Cox proportional hazard. Results. Thirty-six of 41 patients had adequate information with a minimum of 1-year followup. Favorable surgical outcome was identified in 49% of patients at 1 year, and 35% at 4-year. On scalp EEG, an ictal onset pattern consisting of focal beta-frequency discharge (>13–125 Hz) was associated with favorable surgical outcome (P=0.02). Similarly, a focal fast-frequency oscillation (>13–125 Hz) on iEEG at ictal onset was associated with favorable outcome (P=0.03). Discussion. A focal fast-frequency discharge at ictal onset identifies nonlesional MRI, extratemporal epilepsy patients likely to have a favorable outcome after resective epilepsy surgery.