Back to Authors

McAleer, Mary Frances

https://orcid.org/0000-0003-0585-1712

Mayo Clinic

The University of Texas MD Anderson Cancer Center

Citations 13

Efficacy of proton therapy in children with high‐risk and locally recurrent neuroblastoma
Bagley, Alexander F. , Grosshans, David R. , Philip, Nancy V., McAleer, Mary Frances , McGovern, Susan L. , Lassen–Ramshad, Yasmin , Mahajan, Anita , Paulino, Arnold C. , Foster, Jennifer , Paulino, Arnold C , Bagley, Alexander F

Pediatric Blood & Cancer | May 3, 2019 | Volume: 66 | Issue: 8 | Pages: No page available

10.1002/pbc.27786 Get It

Abstract Purpose Proton therapy is currently used in the management of pediatric tumors to decrease late toxicities. However, one of the criticisms of proton therapy is the limited data regarding efficacy on disease control. The purpose of this study was to examine local and distant control rates after proton therapy for neuroblastoma. Methods and materials Eighteen patients with high‐risk ( n = 16) and locally recurrent neuroblastoma ( n = 2) were treated with curative intent and received proton therapy to the primary site and up to three post‐induction MIBG‐avid metastatic sites. Primary sites ( n = 18) were treated to 21–36 Gy (relative biological effectiveness [RBE]), and metastatic sites ( n = 16) were treated to 21–24 Gy (RBE). Local control and survival rates were calculated using the Kaplan–Meier method. Results With a median follow‐up of 60.2 months, two‐ and five‐year local control rates at the irradiated primary site were 94% and 87%, respectively. No failures at irradiated distant metastatic sites were observed. The five‐year progression‐free survival (PFS) was 64%, and the five‐year overall survival (OS) was 94%. The extent of surgical resection was not associated with local control, PFS, or OS. No radiation‐related nephropathy or hepatopathy was reported. Conclusions Excellent local control was achieved using proton therapy to the primary and post‐induction MIBG‐positive distant sites. The predominant site of failure is progression in post‐induction non‐MIBG‐avid distant sites. Although proton therapy provides high rates of local control with acceptable toxicity for neuroblastoma, further advances in systemic therapy are needed for the improved control of systemic disease.
Increased risk of pseudoprogression among pediatric low-grade glioma patients treated with proton versus photon radiotherapy
Ludmir, Ethan B. , Mahajan, Anita , Jones, Jeremy , Ketonen, Leena , Su, Jack , Grosshans, David R. , McAleer, Mary Frances, McGovern, Susan L. , Lassen–Ramshad, Yasmin , Adesina, Adekunle M. , Dauser, Robert C., Weinberg, Jeffrey S. , Chintagumpala, Murali , Ludmir, Ethan B , Paulino, Arnold C. , McAleer, Mary Frances

Neuro-Oncology | February 6, 2019 | Volume: 21 | Issue: 5 | Pages: 686-695

10.1093/neuonc/noz042 Get It

Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch
Luo, Dershan , Yang, James N., Yang, Jinzhong , Chang, Eric L. , Brown, Paul D. , McAleer, Mary Frances , Ghia, Amol J. , Wang, Xin , Zhao, Zhongxiang , Li, Jing , Yang, Jinzhong

Journal of Applied Clinical Medical Physics | August 8, 2017 | Volume: 18 | Issue: 5 | Pages: 225-236

10.1002/acm2.12153 Get It

AbstractThe purpose of this study is to identify regions of spinal column in which more than three contiguous vertebrae can be reliably and quickly aligned within 1 mm using a 6‐degree (6D) couch and full body immobilization device. We analyzed 45 cases treated over a 3‐month period. Each case was aligned using ExacTrac x‐ray positioning system with integrated 6D couch to be within 1° and 1 mm in all six dimensions. Cone‐Beam computed tomography (CBCT) with at least 17.5 cm field of view (FOV) in the superior–inferior direction was taken immediately after ExacTrac positioning. It was used to examine the residual error of five to nine contiguous vertebrae visible in the FOV. The residual error of each vertebra was determined by expanding/contracting the vertebrae contour with a margin in millimeter integrals on the planning CT such that the new contours would enclose the corresponding vertebrae contour on CBCT. Submillimeter initial setup accuracy was consistently achieved in 98% (40/41) cases for a span of five or more vertebrae starting from T2 vertebra and extending caudally to S5. The curvature of spinal column along the cervical region and cervicothoracic junction was not easily reproducible between treatment and simulation. Fifty‐seven percent (8/14) of cases in this region had residual setup error of more than 1 mm in nearby vertebrae after alignment using 6D couch with image guidance. In conclusion, 6D couch integrated with image guidance is convenient and accurately corrects small rotational shifts. Consequently, more than three contiguous vertebrae can be aligned within 1 mm with immobilization that reliably reproduces the curvature of the thoracic and lumbar spinal column. Ability of accurate setup is becoming less a concern in limiting the use of stereotactic radiosurgery or stereotactic body radiation therapy to treat multilevel spinal target.