One commonly reported complication of pyrolytic carbon arthroplasty at the proximal interphalangeal (PIP) joint is an annoying, painless, squeaking postoperatively. This squeak has been anecdotally associated with implant loosening or impending dislocation. The purpose of this study was to investigate the etiology of this squeaking. Proximal and distal components of the pyrolytic carbon PIP implant were inserted into foam bones and mounted onto an oscillating test device. We evaluated the effect of 96 combinations of load, velocity, contact angle, implant size, lubrication, and displacement amplitude over a total of 300 cycles for each condition. Sound analysis was performed on squeaking conditions. Fourteen conditions resulted in squeaking, all with a sound pattern similar to that noted clinically. Unlubricated, “dry” joints did not squeak. Squeaking most commonly occurred with fetal bovine serum lubrication, at higher loads, and at 0 deg hyperextension. Hyaluronic acid viscosupplementation stopped the squeaking in all cases.
Material properties of the plantar aponeurosis were determined by a two-dimensional video tracking method to simultaneously measure the aponeurosis deformation. Failure loads averaged 1189 ± 244 N and were higher in men. Average stiffness of the intact fascia was 203.7 ± 50.5 N/mm at a loading rate of 11.12 N/sec and it did not vary significantly for the loading rates of 11.12 to 1112 N/sec. The high tensile loads required for failure were consistent with clinical and biomechanical studies and indicated the importance of the aponeurosis in foot function and arch stability.
Evaluation of Fracture Resistance in Aqueous Environment of Four Restorative Systems for Posterior Applications. Part 1
AbstractPurposeThe goals of this study were to: (1) establish a range of the performance of four restorative systems for posterior single‐tooth crowns under single load to fracture submerged in an aqueous environment, (2) identify restorative system(s) of interest to be examined in the second study phase under sliding contact step‐stress fatigue as full‐contour anatomically appropriate single posterior tooth restoration(s), (3) establish a range for loading/testing for phase 2.Materials and MethodsForty specimens (n = 10/group) of 2 mm uniform thickness were tested. Group 1: monolithic lithium disilicate IPS e.max Press; group 2: IPS e.max ZirPress, 0.8 mm zirconia core with 1.2 mm pressed veneering porcelain; group 3: IPS e.max ZirPress, 0.4 mm zirconia core with 1.6 mm pressed veneering porcelain; group 4: IPS InLine PoM. Specimens were bonded to a block of polycast acrylic resin on a 30° sloped surface with resin cement. Specimens were axially single loaded to failure while submerged under water.ResultsThere was a statistically significant difference (p < 0.001) in failure load among the four restorative systems. Lithium disilicate showed a mean failure load similar to mean maximum posterior bite forces (743.1 ± 114.3 N). IPS e.max Zirpress with a 0.4 mm zirconia core exhibited the lowest mean failure load (371.4 ± 123.0 N).ConclusionFracture resistance of monolithic lithium disilicate in an aqueous environment is promising and requires second phase testing to evaluate the potential of various thicknesses appropriate for posterior single tooth applications. Doubling the IPS e.max Zirpress zirconia core from 0.4 mm to 0.8 mm increased the fracture resistance of this restorative system threefold.
Transverse connectors providing increased stability to the cervical spine rod-screw construct: an in vitro human cadaveric study
Object The object of this study was to determine if the addition of transverse connectors (TCs) to a rod-screw construct leads to increased stabilization of the cervical spine. Methods Eleven human cadaveric cervical spines (C2–T1) were used to examine the effect of adding connectors to a C3–7 rod-screw construct in 3 models of instability: 1) C3–6 wide laminectomy, 2) wide laminectomy and 50% foraminotomy at C4–5 and C5–6, and 3) wide laminectomy with full medial to lateral foraminotomy. Following each destabilization procedure, specimens were tested with no TC, 1 TC between the C-5 screws, and 2 TCs between the C-4 and C-6 screws. Testing of the connectors was conducted in random order. Specimens were subjected to ± 2 Nm of torque in flexion and extension, lateral bending, and axial rotation. Range of motion was determined for each experimental condition. Statistical comparisons were made between the destabilized and intact conditions, and between the addition of TCs and the absence of TCs. Results The progressive destabilization procedures significantly increased motion. The addition of TCs did not significantly change motion in flexion and extension. Lateral bending was significantly decreased with 2 connectors, but not with 1 connector. The greatest effect was on axial rotation. In general, 2 TCs were more restrictive than 1 TC, and decreased motion 10% more than fixation alone. Conclusions Regardless of the degree of cervical destabilization, 1 or 2 TCs decreased motion compared with rods and screws alone. Axial rotation was most affected. Transverse connectors effectively increase the rigidity of rod-screw constructs in the cervical spine. Severe cervical instability can be overcome with the use of 2 TCs, but in cases in which 2 cannot be used, 1 should be adequate and superior to none.
MOMENT ARMS OF THE ARM MUSCLES AT THE GLENOHUMERAL JOINT USING THE TENDON EXCURSION METHOD
Muscle moment arm defines the function of the muscle. To date, moment arms of the arm muscles at the glenohumeral joint using the tendon excursion method have not been reported. As the functions of these muscles at the shoulder joint are controversial, this study was undertaken to determine the moment arms of the long and short heads of the biceps (LHB, SHB), the coracobrachialis, and the long head of the triceps muscles. The moment arms were determined in 10 cadaveric shoulders by measuring the tendon excursion when the arm was rotated by 1 radian (57.3°) in 22 different motions. The LHB was a flexor, horizontal flexor, and abductor. The SHB and coracobrachialis were flexors, horizontal flexors, and adductors. The long head of the triceps was an extensor and adductor. Arm rotation significantly affected the function of the LHB only: it was an internal rotator in flexion and an external rotator in abduction. This study clarifies the individual function of the arm muscles at the glenohumeral joint.
IN VITRO SIMULATION OF THE STANCE PHASE IN HUMAN GAIT
The purpose of this study is to develop an electromechanical system for dynamic simulation of the stance phase of a human gait using cadaveric foot specimens. The system can be used for quantification of foot and ankle pathomechanics and design of foot and ankle reconstructive surgeries. Servo-pneumatic systems were used for application of the tibial weight loading and muscle loadings. A four-bar mechanism was constructed to provide the progressive motion of a tibia during the simulation while the external loadings were simultaneously applied. Muscle loadings were estimated based on the physiological cross-sectional area and normal electromyography (EMG) data with the assumption of the linear EMG–force relationship. Ad hoc tuning of the unknown muscle gains was conducted until a reasonable match with the normal vertical ground reaction force profile, center of pressure advancement, and characteristic foot motion events (heel strike, foot flat, heel rise and toe-off) could be made. Three cadaver feet and an artificial foot were tested with five repeated trials. The simulator reproduced the stance phase of a human gait in the sagittal plane with reasonable accuracy and consistency without compromising either kinematics or kinetics of the foot and ankle complex.
Dynamic Pressure Transmission Through Agarose Gels