Back to Authors

Kallmes, David F.

https://orcid.org/0000-0002-8495-0040

Mayo Clinic

Mayo Clinic

Citations 386

E-106 The effects of admission hyperglycemia and diabetes mellitus on mechanical thrombectomy outcomes: a systematic review and meta-analysis
Bilgin, Cem , Bilgin, G Belge, Jabal, Mohamed Sobhi , Kobeissi, H, Kadirvel, Ramanathan , Brinjikji, W, Kallmes, D, Rabinstein, A, Ghozy, Sherief , Senol, Y, Orscelik, Atakan , Brinjikji, W, Kallmes, David F.

SNIS 22nd annual meeting electronic poster abstracts | July 14, 2025 | Volume: No volume available | Issue: No issue available | Pages: A163.1-A163

10.1136/jnis-2025-snis.222 Get It

E-095 Super bore .088’ aspiration thrombectomy catheters for ischemic stroke: systemic review and meta-analysis
Adusumilli, G, Mlynash, Michael , Kallmes, D, Srivatsan, Aditya , Kallmes, Kevin M , Kallmes, David F. , Lansberg, Maarten G. , Heit, Jeremy J.

SNIS 22nd annual meeting electronic poster abstracts | July 14, 2025 | Volume: No volume available | Issue: No issue available | Pages: A157.1-A157

10.1136/jnis-2025-snis.211 Get It

E-060 The rabbit superior mesenteric artery as an in vivo model for perforator artery occlusion assessment after flow diversion
Cortese, Jonathan, Lortscher, Sarah, Kallmes, David F. , Kadirvel, Ramanathan , Cortese, Jonathan , Bayraktar, E, Dai, Daying , Ognard, Julien , Zarrintan, Armin , Hajj, G El , Ghozy, Sherief , Ding, Yonghong

SNIS 22nd annual meeting electronic poster abstracts | July 14, 2025 | Volume: No volume available | Issue: No issue available | Pages: A132.2-A133

10.1136/jnis-2025-snis.176 Get It

E-052 Advances in endovascular brain computer interface : systematic review and future implications
Kadirvel, R, Kallmes, D, Brinjikji, Waleed , Ognard, Julien , Hajj, G El , Verma, Onam , Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F.

SNIS 22nd annual meeting electronic poster abstracts | July 14, 2025 | Volume: No volume available | Issue: No issue available | Pages: A127.2-A128

10.1136/jnis-2025-snis.168 Get It

E-038 Ex vivo characterization of the compositional and molecular factors associated with tPA resistance of clots retrieved from stroke patients
Alsereidi, F, Mereuta, O, Ranatunga, Wasantha , Kallmes, David F. , Brinjikji, Waleed , Kadirvel, Ramanathan , Reda, A, Ramarajan, Madan Gopal , Alsereidi, Fatmah R. , Ghozy, Sherief , Dai, Daying , Kandasamy, Richard K.

SNIS 22nd annual meeting electronic poster abstracts | July 14, 2025 | Volume: No volume available | Issue: No issue available | Pages: A117.1-A117

10.1136/jnis-2025-snis.154 Get It

Association of Covert Cerebrovascular Disease With Falls Requiring Medical Attention
Clancy, Úna , Puttock, Eric J. , Chen, Wansu , Whiteley, William , Vickery, Ellen M. , Leung, Lester Y. , Luetmer, Patrick H. , Kallmes, David F. , Zheng, Chengyi , Kent, David M. , Whiteley, William N , Zheng, Chengyi , Liu, Hongfang , Kent, David M , Luetmer, Patrick H , Fu, Sunyang , Liu, Hongfang

Stroke | June 27, 2025 | Volume: 56 | Issue: 9 | Pages: 2484-2493

10.1161/strokeaha.124.050137 Get It

BACKGROUND: The impact of covert cerebrovascular disease on falls in the general population is not well-known. Here, we determine the time to a first fall following incidentally detected covert cerebrovascular disease during a clinical neuroimaging episode. METHODS: This longitudinal cohort study assessed computed tomography (CT) and magnetic resonance imaging from 2009 to 2019 of patients aged >50 years registered with Kaiser Permanente Southern California which is a healthcare organization combining health plan coverage with coordinated medical services, excluding those with before stroke/dementia. We extracted evidence of incidental covert brain infarcts (CBI) and white matter hyperintensities/hypoattenuation (WMH) from imaging reports using natural language processing. We examined associations of CBI and WMH with falls requiring medical attention, using Cox proportional hazards regression models with adjustment for 12 variables including age, sex, ethnicity multimorbidity, polypharmacy, and incontinence. RESULTS: We assessed 241 050 patients, mean age 64.9 (SD, 10.42) years, 61.3% female, detecting covert cerebrovascular disease in 31.1% over a mean follow-up duration of 3.04 years. A recorded fall occurred in 21.2% (51 239/241 050) during follow-up. On CT, single fall incidence rate/1000 person-years (p-y) was highest in individuals with both CBI and WMH on CT (129.3 falls/1000 p-y [95% CI, 123.4–135.5]), followed by WMH (109.9 falls/1000 p-y [108.0–111.9]). On magnetic resonance imaging, the incidence rate was the highest with both CBI and WMH (76.3 falls/1000 p-y [95% CI, 69.7–83.2]), followed by CBI (71.4 falls/1000 p-y [95% CI, 65.9–77.2]). The adjusted hazard ratio for single index fall in individuals with CBI on CT was 1.13 (95% CI, 1.09–1.17); versus magnetic resonance imaging 1.17 (95% CI, 1.08–1.27). On CT, the risk for single index fall incrementally increased for mild (1.37 [95% CI, 1.32–1.43]), moderate (1.57 [95% CI, 1.48–1.67]), or severe WMH (1.57 [95% CI, 1.45–1.70]). On magnetic resonance imaging, index fall risk similarly increased with increasing WMH severity: mild (1.11 [95% CI, 1.07–1.17]), moderate (1.21 [95% CI, 1.13–1.28]), and severe WMH (1.34 [95% CI, 1.22–1.46]). CONCLUSIONS: In a large population with neuroimaging, CBI and WMH are independently associated with greater risks of an index fall. Increasing severities of WMH are associated incrementally with fall risk across imaging modalities.
Simulation of cerebrospinal fluid (CSF)-venous fistula embolization in a swine model: A technical video
Bayraktar, Esref Alperen , Cortese, Jonathan, Ognard, Julien , Hajj, G El , Bilgin, Cem , Kadirvel, Ramanathan , Kallmes, David F. , Brinjikji, Waleed , El Hajj, Gerard , Bayraktar, Esref Alperen , Ognard, Julien , Cortese, Jonathan , Bilgin, Cem

Interventional Neuroradiology | June 18, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251349656 Get It

Cerebrospinal fluid venous fistulas (CSFVF) can lead to spontaneous intracranial hypotension, causing debilitating symptoms in patients. The transvenous embolization technique has been developed to occlude leakage sites via an endovascular approach. However, the spinal venous anatomy remains relatively unfamiliar to many neurointerventionalists. This technical video presents a swine model designed to train physicians in navigating the spinal venous system, performing embolization injections, observing their spread, and testing new embolization systems for treating CSFVF. Although there are slight anatomical differences, the spinal venous system in swine closely resembles that of humans, including its navigability and employing liquid embolic agents. We successfully embolized multilevel spinal vasculature that can potentially drain into a fistula formation, without any complications.
Measuring artery diameter in rabbit angiograms for neurovascular disease modeling applications and device testing
Khan, YM , Franklin, J Ford, Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Khan, Yasmine , Franklin, Jack , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yong-Hong , Lortscher, Sarah , Brinjikji, Waleed , Kadirvel, Ram , Kallmes, David F , Cortese, Jonathan

Interventional Neuroradiology | June 10, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251347398 Get It

Background and purpose New Zealand White Rabbits are a useful preclinical model for neurovascular research. Inducing right common carotid artery aneurysms in New Zealand White Rabbits gives researchers the ability to test neurovascular devices in vivo. This study takes advantage of archived angiograms to obtain vascular measurements of interest for future research in rabbit models. Methods Rabbit angiograms from endovascular studies conducted in-house between 2005 and 2024 were analyzed using ImageJ at points of interest along the thoracic and abdominal aorta. Using scale references, the diameters of various New Zealand White Rabbit (2.5–3.5 kg) arteries were measured for aneurysm models and controls. Anatomic vascular variations were categorized and recorded. Results Measurable artery diameters at 39 points of interest were recorded for 170 female New Zealand White Rabbits. Type 1 vascular anatomy was the most common rabbit aortic arch, characterizing 85% of identifiable rabbit anatomies in this study. Conclusion By making these measurements available, this study simplifies future neurovascular studies, allowing for vasculature to be selected by size depending on the application. Additionally, the study offers insight into the relationship between elastase-induced aneurysms and surrounding vasculature size and draws size comparisons between some key arteries of interest.
Impact of aspiration catheter inner diameter on first-pass effect: A systematic review and meta-analysis
Jazayeri, Seyed Behnam , Cortese, Jonathan , Reda, Abdelrahman, Maroufi, Seyed Farzad , Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F. , Cortese, Jonathan , Maroufi, Seyed Farzad , Ghozy, Sherief , Kadirvel, Ram , Kallmes, David F , Reda, Abdullah , Reda, Abdelrahman

Interventional Neuroradiology | June 10, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251345637 Get It

Background The first-pass effect (FPE) refers to the complete or near-complete revascularization with a single pass of mechanical thrombectomy devices. While previous claims suggest a link between larger catheters and the effectiveness of contact aspiration (CA) thrombectomy, no extensive research has confirmed if larger distal inner diameter (ID) catheters achieve higher FPE rates. Methods We searched PubMed, Scopus, and Web of Science to assess the impact of aspiration catheter distal ID size on FPE. The primary outcome was FPE rate, defined as thrombolysis in cerebral ischemia (TICI) grades 2c-3 at first pass, and the secondary outcome was modified FPE (TICI 2b-3 in a single pass). Aspiration catheters were categorized based on distal ID: 0.060–0.069 (medium bore), 0.070–0.074 (large bore), and greater than 0.074 inches (super-large bore). Rates of FPE were pooled using random effect models and compared using a Chi-square test. Results Our study included 34 articles with 4831 patients. FPE rates were 27.7% (95% CI, 15.1–45.3) for medium bore, 46.6% (95% CI, 33.7–59.9) for large, and 58.3% (95% CI, 44.8–70.7) for super-large catheters. The FPE rate was significantly higher for super-large bore catheters compared with other groups (χ² = 7.26, p = 0.03). A similar trend was observed for modified FPE rates, which were 51.1% (95% CI, 45.3–56.8) for medium bore, 60.0% (95% CI, 52.8–66.8) for large bore, and 80% (95% CI, 56.3–94.2) for super-large bore catheters (χ² = 8.14, p = 0.03). Conclusion Our analysis indicates that larger CA catheters are correlated with higher FPE rates.
Diagnostic value of non-invasive large vessel occlusion detection methods: A systematic review and meta-analysis
Jazayeri, Seyed Behnam , Mehrabinejad, Mohammad-Mehdi , Ghozy, Sherief , Hamouda, Noha , Ahmad, Baria , Kadirvel, Ramanathan , Kallmes, David F. , Nejad, Mohammad Mehdi Mehrabi , Ghozy, Sherief , Ahmad, Baria

Interventional Neuroradiology | June 2, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251345631 Get It

Background Accurate and timely prehospital detection of large vessel occlusion (LVO) is critical for optimizing patient triage and initiating appropriate reperfusion therapies. Recent advances in portable stroke detection technologies, such as electroencephalography (EEG) and transcranial Doppler (TCD) ultrasound, offer potential solutions but their diagnostic performance remains unclear. Methods We searched PubMed, Scopus, Embase, and Web of Science, following the PRISMA guidelines. Studies were included if they assessed the diagnostic performance of non-invasive prehospital LVO detection tools compared to CT or MR angiography. Risk of bias was assessed using the QUADAS-2 tool. Results A total of 13 studies were included, examining various portable detection tools including EEG or neurophysiological monitoring, ultrasound-based techniques including TCD or TCCD, portable Openwater optical blood flow monitor and cranial accelerometry. The pooled diagnostic odds ratio (DOR) was 52.7 (95% CI: 28.3–97.8), indicating strong diagnostic performance, with significant heterogeneity among studies (I 2 = 67.3%, P < 0.001). Subgroup analysis revealed that TCD-based methods had the highest DOR (120.4, 95% CI: 76.9–188.7), followed by other tools (26.8, 95% CI: 13.7–52.6), and EEG (18.2, 95% CI: 9.1–36.3). The pooled sensitivity was 87.4% (95% CI: 82.5–91.0) and specificity was 89.39% (95% CI: 83.0–93.5) across all methods. TCD-based methods showed the highest specificity (95.0%, 95% CI: 91.8–97.0). Conclusion Non-invasive prehospital LVO detection tools show promising diagnostic performance, particularly TCD-based methods. Future studies should focus on validating these tools in larger, diverse populations to enhance prehospital stroke triage and improve patient outcomes.