Catheter-Free Arrhythmia Ablation Using Scanned Proton Beams
Suzuki, Atsushi , Deisher, A., Rettmann, Maryam E. , Lehmann, H. Immo , Hohmann, Stephan , Wang, Songyun , Kruse, Jon J. , Cusma, Jack T., Newman, Laura K. , Parker, Kay D., Monahan, Kristi H. , Herman, Michael , Packer, Douglas L. , Deisher, Amanda J, Konishi, Hiroki, Herman, Michael G., Hohmann, Stephan , Suzuki, Atsushi , Konishi, Hiroki

Circulation: Arrhythmia and Electrophysiology | September 13, 2020 | Volume: 13 | Issue: 10 | Pages: No page available

10.1161/circep.120.008838 Get It

Background: Proton beam therapy offers radiophysical properties that are appealing for noninvasive arrhythmia elimination. This study was conducted to use scanned proton beams for ablation of cardiac tissue, investigate electrophysiological outcomes, and characterize the process of lesion formation in a porcine model using particle therapy. Methods: Twenty-five animals received scanned proton beam irradiation. ECG-gated computed tomography scans were acquired at end-expiration breath hold. Structures (atrioventricular junction or left ventricular myocardium) and organs at risk were contoured. Doses of 30, 40, and 55 Gy were delivered during expiration to the atrioventricular junction (n=5) and left ventricular myocardium (n=20) of intact animals. Results: In this study, procedural success was tracked by pacemaker interrogation in the atrioventricular junction group, time-course magnetic resonance imaging in the left ventricular group, and correlation of lesion outcomes displayed in gross and microscopic pathology. Protein extraction (active caspase-3) was performed to investigate tissue apoptosis. Doses of 40 and 55 Gy caused slowing and interruption of cardiac impulse propagation at the atrioventricular junction. In 40 left ventricular irradiated targets, all lesions were identified on magnetic resonance after 12 weeks, being consistent with outcomes from gross pathology. In the majority of cases, lesion size plateaued between 12 and 16 weeks. Active caspase-3 was seen in lesions 12 and 16 weeks after irradiation but not after 20 weeks. Conclusions: Scanned proton beams can be used as a tool for catheter-free ablation, and time-course of tissue apoptosis was consistent with lesion maturation.
Spatial Accuracy of a Clinically Established Noninvasive Electrocardiographic Imaging System for the Detection of Focal Activation in an Intact Porcine Model
Hohmann, Stephan , Rettmann, Maryam E. , Borenstein, Anna, Wang, Songyun , Suzuki, Atsushi , Michalak, Gregory J. , Monahan, Kristi H. , Parker, Kay D., Newman, Laura K. , Packer, Douglas L. , Konishi, Hiroki, Newman, L Katie, Hohmann, Stephan , Konishi, Hiroki

Circulation: Arrhythmia and Electrophysiology | November 11, 2019 | Volume: 12 | Issue: 11 | Pages: No page available

10.1161/circep.119.007570 Get It

Background: Noninvasive electrocardiographic imaging (ECGi) is used clinically to map arrhythmias before ablation. Despite its clinical use, validation data regarding the accuracy of the system for the identification of arrhythmia foci is limited. Methods: Nine pigs underwent closed-chest placement of endocardial fiducial markers, computed tomography, and pacing in all cardiac chambers with ECGi acquisition. Pacing location was reconstructed from biplane fluoroscopy and registered to the computed tomography using the fiducials. A blinded investigator predicted the pacing location from the ECGi data, and the distance to the true pacing catheter tip location was calculated. Results: A total of 109 endocardial and 9 epicardial locations were paced in 9 pigs. ECGi predicted the correct chamber of origin in 85% of atrial and 92% of ventricular sites. Lateral locations were predicted in the correct chamber more often than septal locations (97% versus 79%, P =0.01). Absolute distances in space between the true and predicted pacing locations were 20.7 (13.8–25.6) mm (median and [first–third] quartile). Distances were not significantly different across cardiac chambers. Conclusions: The ECGi system is able to correctly identify the chamber of origin for focal activation in the vast majority of cases. Determination of the true site of origin is possible with sufficient accuracy with consideration of these error estimates.
P298Safety of catheter-free VT ablation: Dose-dependent LVEF changes after proton beam therapy of the LV in a porcine model
Deisher, A., Suzuki, Akihiro , Kruse, Jon J. , Parker, Katrina, Newman, Laura K. , Herman, Michael , Packer, Douglas L. , Hohmann, Stephan , Konishi, Hiroki , Rettmann, Maryam E. , Lehmann, H. Immo

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy564.p298 Get It

Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring
Linte, Cristian A. , Camp, Jon J. , Rettmann, Maryam E. , Haemmerich, Dieter , Aktaş, Mehmet K. , Packer, Douglas L. , Holmes, David R. , Huang, David T.

Journal of Medical Imaging | March 1, 2018 | Volume: 5 | Issue: 02 | Pages: 1

10.1117/1.jmi.5.2.021218 Get It

Integration of myocardial scar identified by preoperative delayed contrast-enhanced MRI into a high-resolution mapping system for planning and guidance of VT ablation procedures
Rettmann, Maryam E. , Suzuki, Atsushi , Wang, S., Pottinger, Nathan, Arter, James, Netzer, A, Viker, Kimberly, Packer, Douglas L. , Parker, K.

SPIE Proceedings | March 3, 2017 | Volume: 10135 | Issue: No issue available | Pages: 101351P

10.1117/12.2255933 Get It