AbstractBackgroundThe functional lumen imaging probe (FLIP) evaluates esophagogastric junction (EGJ) opening and esophageal contractility. Both post hoc and real‐time analyses are possible, but reproducibility and reliability of analysis remain undefined. This study assesses inter‐ and intra‐rater agreement of normative FLIP measurements among novice and experienced users.MethodsEight motility experts from different institutions independently evaluated de‐identified video recordings from 27 asymptomatic healthy subjects using FLIP. Interpretation methods simulating a post‐procedure and a live procedure setting were tested. Novice FLIP users (n = 3) received training prior to post‐procedure interpretation. Experienced FLIP users (n = 5) interpreted using both methods. Users recorded maximum EGJ and distal esophageal body diameter, distensive pressure, and EGJ distensibility index (EGJ‐DI), at balloon fill volumes of 50‐, 60‐, and 70 ml, as well as repetitive antegrade contractions (RACs). Inter‐ and intra‐rater agreements of diameters, distensive pressure and EGJ‐DI were assessed by intra‐class correlation coefficient (ICC) and Pearson's correlation coefficient (PCC). Percentage agreement evaluated inter‐ and intra‐rater reliability for RACs.Key ResultsNovice and experienced users acquired normative FLIP metrics. Good‐to‐excellent inter‐ and intra‐rater reliability were achieved for all variables at 60 ml balloon fill volumes. Median parameters at 60 ml balloon fill volume were as follows: EGJ‐DI 5.5 mm2/mmHg, maximum EGJ diameter 18.6 mm, distensive pressure at maximum EGJ diameter 48.1 mmHg, and distal esophageal body diameter 19.5 mm.Conclusions and InferencesNormative FLIP parameters can be reliably extracted from FLIP videos using both real‐time and post hoc analyses, with high reliability between experienced and novice users.
Clinical role of ambulatory reflux monitoring in PPI non‐responders: recommendation statements
Summary Background Optimal ambulatory reflux monitoring methodology in symptomatic reflux patients continues to be debated. Aims To utilise published literature and expert opinion to develop recommendation statements addressing use of ambulatory reflux monitoring in clinical practice Methods The RAND Appropriateness Method (RAM) was utilised among 17 experts with discussion, revision and two rounds of ranking of recommendation statements. Ambulatory reflux monitoring protocol, methodology and thresholds ranked as appropriate by ≥80% of panellists met the criteria for appropriateness. Results Prolonged (96‐h recommended) wireless pH monitoring off proton pump inhibitor (PPI) was identified as the appropriate diagnostic tool to assess the need for acid suppression in patients with unproven gastro‐oesophageal reflux disease (GERD) and persisting typical reflux symptoms despite once‐daily PPI. Acid exposure time (AET) <4.0% on all days of monitoring with negative reflux‐symptom association excludes GERD and does not support ongoing PPI treatment. Conversely, AET >6.0% across ≥2 days is conclusive evidence for GERD and supports treatment for GERD, while AET >10% across ≥2 days identifies severe acid burden that supports escalation of anti‐reflux treatment. In previously proven GERD, impedance‐pH monitoring on PPI is helpful in defining refractory GERD and mechanisms of continued symptoms; the presence of <40 reflux events, AET <2.0% and a negative reflux‐symptom association does not support escalation of anti‐reflux treatment. In contrast, AET > 4.0% and positive reflux‐symptom association support escalation of anti‐reflux treatment, including use of invasive therapeutics. Conclusions Statements meeting appropriateness for average clinical care have been identified when utilising reflux monitoring in patients with typical reflux symptoms and PPI non‐response.
Development of quality indicators for the diagnosis and management of achalasia
AbstractBackgroundThe management of achalasia has improved due to diagnostic and therapeutic innovations. However, variability in care delivery remains and no established measures defining quality of care for this population exist. We aimed to use formal methodology to establish quality indicators for achalasia patients.MethodsQuality indicator concepts were identified from the literature, consensus guidelines and clinical experts. Using RAND/University of California, Los Angeles (UCLA) Appropriateness Method, experts in achalasia independently ranked proposed concepts in a two‐round modified Delphi process based on 1) importance, 2) scientific acceptability, 3) usability, and 4) feasibility. Highly valid measures required strict agreement (≧ 80% of panelists) in the range of 7–9 for across all four categories.Key ResultsThere were 17 experts who rated 26 proposed quality indicator topics. In round one, 2 (8%) quality measures were rated valid. In round two, 19 measures were modified based on panel suggestions, and experts rated 10 (53%) of these measures as valid, resulting in a total of 12 quality indicators. Two measures pertained to patient education and five to diagnosis, including discussing treatment options with risk and benefits and using the most recent version of the Chicago Classification to define achalasia phenotypes, respectively. Other indicators pertained to treatment options, such as the use of botulinum toxin for those not considered surgical candidates and management of reflux following achalasia treatment.Conclusions & InferencesUsing a robust methodology, achalasia quality indicators were identified, which can form the basis for establishing quality gaps and generating fully specified quality measures.
Donald O. Castell (1935-2021): A Life Dedicated to Investigation, Mentoring, and Education
Abstract Chicago Classification v4.0 (CCv4.0) is the updated classification scheme for esophageal motility disorders using metrics from high‐resolution manometry (HRM). Fifty‐two diverse international experts separated into seven working subgroups utilized formal validated methodologies over two‐years to develop CCv4.0. Key updates in CCv.4.0 consist of a more rigorous and expansive HRM protocol that incorporates supine and upright test positions as well as provocative testing, a refined definition of esophagogastric junction (EGJ) outflow obstruction (EGJOO), more stringent diagnostic criteria for ineffective esophageal motility and description of baseline EGJ metrics. Further, the CCv4.0 sought to define motility disorder diagnoses as conclusive and inconclusive based on associated symptoms, and findings on provocative testing as well as supportive testing with barium esophagram with tablet and/or functional lumen imaging probe. These changes attempt to minimize ambiguity in prior iterations of Chicago Classification and provide more standardized and rigorous criteria for patterns of disorders of peristalsis and obstruction at the EGJ.