Back to Authors

Hall, Christiana E.

Mayo Clinic

The University of Texas Southwestern Medical Center

Citations 3

Accuracy of the ABC/2 Score for Intracerebral Hemorrhage
Webb, Alastair J.S. , Ullman, Natalie , Morgan, Tim C., Muschelli, John , Kornbluth, Joshua , Awad, Issam A. , Rosenblum, Michael , Ziai, Wendy , Zuccarrello, Mario, Aldrich, François, John, Sayona , Harnof, Sagi , Lopez, George Α. , Broaddus, William C. , Wijman, Christine A.C., Vespa, Paul , Bullock, Ross, Haines, Stephen J. , Cruz‐Flores, Salvador , Tuhrim, Stan, Hill, Michael D. , Narayan, Raj K. , Hanley, Daniel F. , Tayal, Ashis , Díaz, Alberto Torres, Hoffer, Alan , Moheet, Asma , Agarwal, Sachin , Markowski, Mason, Rosenthal, Guy , Kureshi, Inam, Varelas, Panayiotis N. , Pinto, Pedro Telles Cougo, Camarata, Paul J. , Helms, Ann , Shahi, Kavian, Sinclair, David, Gizzi, Martin , LeDoux, David, Torbey, Michel , Cockroft, Kevin M. , Antezana, David, Margalit, Nevo, Crabtree, H. Mark, Lovick, Darren, Weaver, Michael, Leonardo, Jody, Ardelt, Agnieszka, Csiba, László , Wartenberg, Katja E. , Bösel, Julian , Adams, Harold P. , Hobohm, Carsten , Kerz, Thomas , Wechsler, Lawrence R. , Gardner, Paul A. , Decker, David A., Gonzales, Nicole R. , Caron, Jean-Louis, Hall, Christiana E., Ansari, Safdar , Luft, Andreas R. , Graham, R. Scott, Tucker, Kristi, Webb, Alastair Js , Mayo, Stephen L. , Martí‐Fábregas, Joan , Seder, David B. , Freeman, William D. , Lazaridis, Christos , LeDoux, David, Latorre, Julius Gene , Venkatasubramanian, Chitra , Jallo, Jack , Reinert, Michael , Butcher, Kenneth , Adeoye, Opeolu M , Testai, Fernando D. , Bulters, Diederik , Caron, Jean-Louis R., Arikán, Fuat , Hill, Michael D , Hanley, Daniel F , Lopez, George

Stroke | August 5, 2015 | Volume: 46 | Issue: 9 | Pages: 2470-2476

10.1161/strokeaha.114.007343 Get It

Background and Purpose— The ABC/2 score estimates intracerebral hemorrhage (ICH) volume, yet validations have been limited by small samples and inappropriate outcome measures. We determined accuracy of the ABC/2 score calculated at a specialized reading center (RC-ABC) or local site (site-ABC) versus the reference-standard computed tomography–based planimetry (CTP). Methods— In Minimally Invasive Surgery Plus Recombinant Tissue-Type Plasminogen Activator for Intracerebral Hemorrhage Evacuation-II (MISTIE-II), Clot Lysis Evaluation of Accelerated Resolution of Intraventricular Hemorrhage (CLEAR-IVH) and CLEAR-III trials. ICH volume was prospectively calculated by CTP, RC-ABC, and site-ABC. Agreement between CTP and ABC/2 was defined as an absolute difference up to 5 mL and relative difference within 20%. Determinants of ABC/2 accuracy were assessed by logistic regression. Results— In 4369 scans from 507 patients, CTP was more strongly correlated with RC-ABC ( r 2 =0.93) than with site-ABC ( r 2 =0.87). Although RC-ABC overestimated CTP-based volume on average (RC-ABC, 15.2 cm 3 ; CTP, 12.7 cm3), agreement was reasonable when categorized into mild, moderate, and severe ICH (κ=0.75; P <0.001). This was consistent with overestimation of ICH volume in 6 of 8 previous studies. Agreement with CTP was greater for RC-ABC (84% within 5 mL; 48% of scans within 20%) than for site-ABC (81% within 5 mL; 41% within 20%). RC-ABC had moderate accuracy for detecting ≥5 mL change in CTP volume between consecutive scans (sensitivity, 0.76; specificity, 0.86) and was more accurate with smaller ICH, thalamic hemorrhage, and homogeneous clots. Conclusions— ABC/2 scores at local or central sites are sufficiently accurate to categorize ICH volume and assess eligibility for the CLEAR-III and MISTIE III studies and moderately accurate for change in ICH volume. However, accuracy decreases with large, irregular, or lobar clots. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: MISTIE-II NCT00224770; CLEAR-III NCT00784134.
REACH
Hess, David C. , Wang, Samuel J. , Hamilton, William , Pardue, Carol, Waller, Jennifer L. , Gross, Hartmut, Nichols, Fenwick T. , Hall, Christiana E., Adams, Robert J. , Lee, Sung

Stroke | July 28, 2005 | Volume: 36 | Issue: 9 | Pages: 2018-2020

10.1161/01.str.0000177534.02969.e4 Get It

Background and Purpose— Development of stroke networks is critical to bringing guideline-driven stroke care to rural, underserved areas. Methods— A Web-based telestroke tool, REACH, was developed to provide a foundation for a rural stroke network that delivered acute stroke consults 24 hours per day 7 days per week to 8 rural community hospitals in Georgia. Results— There were 194 acute stroke consults delivered. Thirty patients were treated with tissue plasminogen activator (tPA). The mean National Institutes of Health Stroke Score (NIHSS) was 15.4, and the median NIHSS was 12.5. The mean onset to treatment time (OTT) was 122 minutes. The OTT dropped from 143 minutes in the first 10 patients treated to 111 minutes in last 20 patients. Of the 30 patients treated with tPA, 23% (7) were treated in ≤90 minutes and 60% (18) were treated within 2 hours. There were no symptomatic intracerebral hemorrhages. Conclusions— The REACH telestroke system permits the rapid and safe use of tPA in rural community hospitals. Over time, the system became more efficient and OTT decreased.