Back to Authors

Rosenblum, Michael

https://orcid.org/0000-0001-7411-4172

Mayo Clinic

Johns Hopkins University

Citations 2

Multifocal Cryoballoon Ablation for Eradication of Barrett's Esophagus-Related Neoplasia: A Prospective Multicenter Clinical Trial
Rosenblum, Michael , Dumot, John A. , Chak, Amitabh , Iyer, Prasad G. , Khara, Harshit S. , Corbett, F Scott , McKinley, Matthew , Shin, Eun Ji , Waxman, Irving , Infantolino, Anthony, Tofani, Christina , Samarasena, Jason , Chang, Kenneth J. , Wang, Bingkai , Goldblum, John R. , Voltaggio, Lysandra , Lightdale, Charles J. , Shaheen, Nicholas J. , Iyer, Prasad, Canto, Marcia Irene , Trindade, Arvind J. , Abrams, Julian A , Diehl, David L. , Montgomery, Elizabeth Anne

American Journal of Gastroenterology | October 2, 2020 | Volume: 115 | Issue: 11 | Pages: 1879-1890

10.14309/ajg.0000000000000822 Get It

INTRODUCTION: Ablation of Barrett's esophagus (BE) is the preferred approach for the treatment of neoplasia without visible lesions. Limited data on cryoballoon ablation (CBA) suggest its potential clinical utility. We evaluated the safety and efficacy of CBA in a multicenter study of patients with neoplastic BE. METHODS: In a prospective clinical trial, 11 academic and community centers recruited consecutive patients with BE of 1–6 cm length and low-grade dysplasia, high-grade dysplasia (HGD), or intramucosal adenocarcinoma (ImCA) confirmed by central pathology. Patients with symptomatic pre-existing strictures or visible BE lesions had dilation or endoscopic mucosal resection (EMR), respectively, before enrollment. A nitrous oxide cryoballoon focal ablation system was used to treat all visible columnar mucosa in up to 5 sessions. Study end points included complete eradication of all dysplasia (CE-D) and intestinal metaplasia (CE-IM) at 1 year. RESULTS: One hundred twenty patients with BE with ImCA (20%), HGD (56%), or low-grade dysplasia (23%) were enrolled. In the intention-to-treat analysis, the CE-D and CE-IM rates were 76% and 72%, respectively. In the per-protocol analysis (94 patients), the CE-D and CE-IM rates were 97% and 91%, respectively. Postablation pain was mild and short lived. Fifteen subjects (12.5%) developed strictures requiring dilation. One patient (0.8%) with HGD progressed to ImCA, which was successfully treated with EMR. Another patient (0.8%) developed gastrointestinal bleeding associated with clopidogrel use. One patient (0.8%) had buried BE with HGD in 1 biopsy, not confirmed by subsequent EMR. DISCUSSION: In patients with neoplastic BE, CBA was safe and effective. Head-to-head comparisons between CBA and other ablation modalities are warranted (clinicaltrials.gov registration NCT02514525).
Accuracy of the ABC/2 Score for Intracerebral Hemorrhage
Webb, Alastair J.S. , Ullman, Natalie , Morgan, Tim C., Muschelli, John , Kornbluth, Joshua , Awad, Issam A. , Rosenblum, Michael , Ziai, Wendy , Zuccarrello, Mario, Aldrich, François, John, Sayona , Harnof, Sagi , Lopez, George Α. , Broaddus, William C. , Wijman, Christine A.C., Vespa, Paul , Bullock, Ross, Haines, Stephen J. , Cruz‐Flores, Salvador , Tuhrim, Stan, Hill, Michael D. , Narayan, Raj K. , Hanley, Daniel F. , Tayal, Ashis , Díaz, Alberto Torres, Hoffer, Alan , Moheet, Asma , Agarwal, Sachin , Markowski, Mason, Rosenthal, Guy , Kureshi, Inam, Varelas, Panayiotis N. , Pinto, Pedro Telles Cougo, Camarata, Paul J. , Helms, Ann , Shahi, Kavian, Sinclair, David, Gizzi, Martin , LeDoux, David, Torbey, Michel , Cockroft, Kevin M. , Antezana, David, Margalit, Nevo, Crabtree, H. Mark, Lovick, Darren, Weaver, Michael, Leonardo, Jody, Ardelt, Agnieszka, Csiba, László , Wartenberg, Katja E. , Bösel, Julian , Adams, Harold P. , Hobohm, Carsten , Kerz, Thomas , Wechsler, Lawrence R. , Gardner, Paul A. , Decker, David A., Gonzales, Nicole R. , Caron, Jean-Louis, Hall, Christiana E., Ansari, Safdar , Luft, Andreas R. , Graham, R. Scott, Tucker, Kristi, Webb, Alastair Js , Mayo, Stephen L. , Martí‐Fábregas, Joan , Seder, David B. , Freeman, William D. , Lazaridis, Christos , LeDoux, David, Latorre, Julius Gene , Venkatasubramanian, Chitra , Jallo, Jack , Reinert, Michael , Butcher, Kenneth , Adeoye, Opeolu M , Testai, Fernando D. , Bulters, Diederik , Caron, Jean-Louis R., Arikán, Fuat , Hill, Michael D , Hanley, Daniel F , Lopez, George

Stroke | August 5, 2015 | Volume: 46 | Issue: 9 | Pages: 2470-2476

10.1161/strokeaha.114.007343 Get It

Background and Purpose— The ABC/2 score estimates intracerebral hemorrhage (ICH) volume, yet validations have been limited by small samples and inappropriate outcome measures. We determined accuracy of the ABC/2 score calculated at a specialized reading center (RC-ABC) or local site (site-ABC) versus the reference-standard computed tomography–based planimetry (CTP). Methods— In Minimally Invasive Surgery Plus Recombinant Tissue-Type Plasminogen Activator for Intracerebral Hemorrhage Evacuation-II (MISTIE-II), Clot Lysis Evaluation of Accelerated Resolution of Intraventricular Hemorrhage (CLEAR-IVH) and CLEAR-III trials. ICH volume was prospectively calculated by CTP, RC-ABC, and site-ABC. Agreement between CTP and ABC/2 was defined as an absolute difference up to 5 mL and relative difference within 20%. Determinants of ABC/2 accuracy were assessed by logistic regression. Results— In 4369 scans from 507 patients, CTP was more strongly correlated with RC-ABC ( r 2 =0.93) than with site-ABC ( r 2 =0.87). Although RC-ABC overestimated CTP-based volume on average (RC-ABC, 15.2 cm 3 ; CTP, 12.7 cm3), agreement was reasonable when categorized into mild, moderate, and severe ICH (κ=0.75; P <0.001). This was consistent with overestimation of ICH volume in 6 of 8 previous studies. Agreement with CTP was greater for RC-ABC (84% within 5 mL; 48% of scans within 20%) than for site-ABC (81% within 5 mL; 41% within 20%). RC-ABC had moderate accuracy for detecting ≥5 mL change in CTP volume between consecutive scans (sensitivity, 0.76; specificity, 0.86) and was more accurate with smaller ICH, thalamic hemorrhage, and homogeneous clots. Conclusions— ABC/2 scores at local or central sites are sufficiently accurate to categorize ICH volume and assess eligibility for the CLEAR-III and MISTIE III studies and moderately accurate for change in ICH volume. However, accuracy decreases with large, irregular, or lobar clots. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: MISTIE-II NCT00224770; CLEAR-III NCT00784134.