Abstract 5919: Performance of the Oncuria-detect bladder cancer test for evaluating patients presenting with hematuria: results from a real-world clinical setting
Abstract Background and Objective: Bladder cancer is the 9th most diagnosed cancer worldwide with high incidences reported in Europe and the United States. Here, we evaluated the real-world performance of a commercially available multiplex immunoassay Oncuria-Detect that detects bladder cancer by simultaneously measuring a panel of 10 biomarker proteins in naturally voided urine samples. Methods: We tested prospectively collected urine samples from a real-world cohort of 1, 002 patients presenting to five USA centers, one European center and one Japanese center with hematuria. Assay results were collated with patient clinical data and a cancer diagnosis was defined by biopsy and pathology. The prevalence of bladder cancer in the cohort was 15.9%. Results: In a training set (n=684), the Oncuria-Detect assay correctly identified bladder cancer in 94/109 cases, representing a sensitivity of 91.8%, specificity of 71.6% (AUC 0.885; 95% CI 0.843 - 0.927) and with improved performance for high-grade bladder cancer and muscle-invasive bladder cancer (sensitivity 93.6% and 92.1%, respectively). In a test cohort of n =339 the AUC for detecting bladder cancer was 0.850 (95% CI 0.779-0.920). Conclusions and Implications: The multiplex Oncuria-Detect assay identified bladder cancer with high sensitivity and NPV, for low-grade and high-grade tumors alike. Oncuria-Detect’s high NPV could effectively rule out 66% of patients from requiring subsequent cystoscopy. Citation Format: Ian Pagano, Zhen Zhang, Sergei Tikhonenkov, Florence Le Calvez-Kelm, Steve Goodison, Toru Sakatani, Kaoru Murakami, Takashi Kobayashi, Howard Kim, Riko Lee, Sunao Tanaka, Charles J. Rosser, Hideki Furuya. Performance of the Oncuria-detect bladder cancer test for evaluating patients presenting with hematuria: results from a real-world clinical setting [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2025; Part 1 (Regular Abstracts); 2025 Apr 25-30; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2025;85(8_Suppl_1):Abstract nr 5919.
Abstract A072: Oncuria®-Monitor, a non-invasive test for the detection of recurrent bladder cancer: Cross sectional performance evaluation from a multicenter study
Abstract Up to 70% of patients with non-muscle invasive bladder cancer (NMIBC) experience disease recurrence, making it one of the most prevalent cancers in the US. The purpose of this study was to test the performance of Oncuria®-Monitor, a multiplex urinary biomarker assay for the monitoring of voided urine for recurrent bladder cancer. This cross-sectional, multicenter study included a total of 283 subjects with a history of bladder cancer. Voided urine specimens were collected prior to any procedures for multiplex analysis. The diagnostic performance of the biomarker panel was assessed using receiver operator curves (ROC) and descriptive statistical values (e.g., sensitivity and specificity) and compared with the patients’ clinical data and final diagnosis as defined by the results of cystoscopy. Oncuria®-Monitor achieved an overall sensitivity of 94.3%, specificity of 83.6% and negative predictive valuer (NPV) of 96.2% for the detection of recurrent bladder cancer. Patient summary: We conducted a large cross-sectional clinical study for detecting recurrent bladder cancer with a novel, simple urine test (Oncuria®- Monitor), which measures 10 bladder cancer associated proteins in a single voided urine and can be used to detect recurrent bladder cancer. We analyzed urines from 283 patients and demonstrated that Oncuria®-Monitor can detect recurrent bladder cancer with a high degree of accuracy, specifically in patients with high grade or high stage disease. In conclusion, the novel Oncuria®-Monitor urine test can be used to surveil patients with a history of bladder cancer. Citation Format: Zhen Zhang, Florence Le Calvez-Kelm, Makito Miyake, Ian Pagano, Takuto Shimizu, Sergei Tikhonenkov, Sunao Tanaka, Charles J Rosser, Steve Goodison, Hideki Furuya. Oncuria®-Monitor, a non-invasive test for the detection of recurrent bladder cancer: Cross sectional performance evaluation from a multicenter study [abstract]. In: Proceedings of the AACR Special Conference: Liquid Biopsy: From Discovery to Clinical Implementation; 2024 Nov 13-16; San Diego, CA. Philadelphia (PA): AACR; Clin Cancer Res 2024;30(21_Suppl):Abstract nr A072.
Abstract A071: Performance of the Oncuria®-Detect test for the evaluation of patients presenting with hematuria: Results from a real world clinical setting
Abstract Bladder cancer is the 9th most diagnosed cancer worldwide with higher incidences reported in Europe and the United States. Here, we evaluate the performance of a novel, commercially available multiplex immunoassay querying for 10 proteins associated with a bladder cancer diagnostic signature (Oncuria®-Detect, Nonagen Bioscience Corp, Los Angeles, CA, US) for the detection of de novo bladder cancer, in a large prospectively collected real world cohort comprised of 995 patients, across seven centers, presenting with hematuria. The results were compared with the patients’ clinical data and final diagnosis as defined by the results of cystoscopy, with a prevalence of bladder cancer of 15.9%. In the test cohort, Oncuria®-Detect detected bladder tumors in 94/109 cancers, giving overall sensitivity of 86.2% and an overall negative predictive value (NPV) of 96.7% with corresponding specificity of 80.2% with favorable performance characteristics in high grade bladder cancer and muscle-invasive bladder cancer. Patient summary: We conducted a large cross-sectional clinical study for detecting de novo bladder cancer with a novel, simple urine test (Oncuria®-Detect), which measures 10 bladder cancer associated proteins in a single voided urine sample. We analyzed urines from 995 patients and demonstrated that the new urine test can detect bladder cancer with a high degree of accuracy, specifically in patients with high grade or high stage disease. In conclusion, the novel Oncuria®-Detect urine test can be used to help detect new bladder cancers. Citation Format: Ian Pagano, Sergei Tikhonenkov, Florence Le Calvez-Kelm, Steve Goodison, Zhen Zhang, Toru Sakatani, Kaoru Murakami, Howard Kim, Riko Lee, Sunao Tanaka, Charles J Rosser, Hideki Furuya. Performance of the Oncuria®-Detect test for the evaluation of patients presenting with hematuria: Results from a real world clinical setting [abstract]. In: Proceedings of the AACR Special Conference: Liquid Biopsy: From Discovery to Clinical Implementation; 2024 Nov 13-16; San Diego, CA. Philadelphia (PA): AACR; Clin Cancer Res 2024;30(21_Suppl):Abstract nr A071.
No evidence that protein truncating variants in BRIP1 are associated with breast cancer risk: implications for gene panel testing
Background BRCA1 interacting protein C-terminal helicase 1 (BRIP1) is one of the Fanconi Anaemia Complementation (FANC) group family of DNA repair proteins. Biallelic mutations in BRIP1 are responsible for FANC group J, and previous studies have also suggested that rare protein truncating variants in BRIP1 are associated with an increased risk of breast cancer. These studies have led to inclusion of BRIP1 on targeted sequencing panels for breast cancer risk prediction. Methods We evaluated a truncating variant, p.Arg798Ter (rs137852986), and 10 missense variants of BRIP1, in 48 144 cases and 43 607 controls of European origin, drawn from 41 studies participating in the Breast Cancer Association Consortium (BCAC). Additionally, we sequenced the coding regions of BRIP1 in 13 213 cases and 5242 controls from the UK, 1313 cases and 1123 controls from three population-based studies as part of the Breast Cancer Family Registry, and 1853 familial cases and 2001 controls from Australia. Results The rare truncating allele of rs137852986 was observed in 23 cases and 18 controls in Europeans in BCAC (OR 1.09, 95% CI 0.58 to 2.03, p=0.79). Truncating variants were found in the sequencing studies in 34 cases (0.21%) and 19 controls (0.23%) (combined OR 0.90, 95% CI 0.48 to 1.70, p=0.75). Conclusions These results suggest that truncating variants in BRIP1, and in particular p.Arg798Ter, are not associated with a substantial increase in breast cancer risk. Such observations have important implications for the reporting of results from breast cancer screening panels.