Back to Authors

Ehman, Richard L.

https://orcid.org/0000-0001-7041-5074

Mayo Clinic

Mayo Clinic

Citations 132

Magnetic resonance elastography: Status of clinical applications
Ehman, Richard L.

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1773-1773

10.1121/1.5035802 Get It

Magnetic resonance elastography (MRE) is an imaging technology that has been available as an FDA-cleared upgrade to MRI systems since 2009. Worldwide, MRE technology has been installed on approximately 1000 MRI systems. In October 2017, the AMA approved the creation of a CPT code for MRE. In MRE, propagating shear waves in the range of 30–300 Hz are generated in tissue, and imaged with a phase contrast MRI technique. The wave images are processed with an inversion algorithm to generate cross-sectional images quantitatively depicting the complex shear modulus of tissue. The main application of MRE is currently in noninvasive diagnosis of chronic liver disease. Published studies have established the MRE is the most accurate and technically successful non-invasive modality for diagnosing liver fibrosis. Many other promising applications of MRE are being explored by investigators around the world, including assessment of diseases of the brain, heart, lung, and muscle and tumors of breast, liver, prostate, liver, and other organs. The new applications that closest adoption in clinical practice are (1) assessment of brain disease and (2) advanced diagnosis of liver disease. These new applications require acquisition sequences and processing algorithms that are more advanced than the current product MRE techniques.
Pancreatic Stiffness Quantified with MR Elastography: Relationship to Postoperative Pancreatic Fistula after Pancreaticoenteric Anastomosis
Shi, Yu , Liu, Ying , Gao, Feng , Liu, Yanqing , Tao, Shengzhen , Li, Yue , Glaser, Kevin J. , Guo, Qiyong , Guo, Qiyong , Ehman, Richard L.

Radiology | April 17, 2018 | Volume: 288 | Issue: 2 | Pages: 476-484

10.1148/radiol.2018170450 Get It

Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI
Sui, Yi , Arunachalam, Shivaram P. , Arani, Arvin , Trzasko, Joshua D. , Young, Phillip M. , Glockner, James F., Glaser, Kevin J. , Lake, David S. , McGee, Kiaran P. , Rossman, Phillip J. , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Manduca, Armando , Ehman, Richard L. , Sui, Yi

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 Get It

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Artificial neural networks for stiffness estimation in magnetic resonance elastography
Murphy, Matthew C. , Trzasko, Joshua D. , Glaser, Kevin J. , Manduca, Armando , Huston, John , Ehman, Richard L.

Magnetic Resonance in Medicine | November 29, 2017 | Volume: 80 | Issue: 1 | Pages: 351-360

10.1002/mrm.27019 Get It

PurposeTo investigate the feasibility of using artificial neural networks to estimate stiffness from MR elastography (MRE) data.MethodsArtificial neural networks were fit using model‐based training patterns to estimate stiffness from images of displacement using a patch size of ∼1 cm in each dimension. These neural network inversions (NNIs) were then evaluated in a set of simulation experiments designed to investigate the effects of wave interference and noise on NNI accuracy. NNI was also tested in vivo, comparing NNI results against currently used methods.ResultsIn 4 simulation experiments, NNI performed as well or better than direct inversion (DI) for predicting the known stiffness of the data. Summary NNI results were also shown to be significantly correlated with DI results in the liver (R2 = 0.974) and in the brain (R2 = 0.915), and also correlated with established biological effects including fibrosis stage in the liver and age in the brain. Finally, repeatability error was lower in the brain using NNI compared to DI, and voxel‐wise modeling using NNI stiffness maps detected larger effects than using DI maps with similar levels of smoothing.ConclusionArtificial neural networks represent a new approach to inversion of MRE data. Summary results from NNI and DI are highly correlated and both are capable of detecting biologically relevant signals. Preliminary evidence suggests that NNI stiffness estimates may be more resistant to noise than an algebraic DI approach. Taken together, these results merit future investigation into NNIs to improve the estimation of stiffness in small regions. Magn Reson Med 80:351–360, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assessment of advanced hepatic MR elastography methods for susceptibility artifact suppression in clinical patients
Wang, Jin , Glaser, Kevin J. , Zhang, Tianhui , Shan, Qungang , He, Bingjun , Yin, Meng , Dzyubak, Bogdan , Kugel, Jennifer L., Kruse, Scott A., Grimm, Roger C., Venkatesh, Sudhakar K. , Dzyubak, Bogdan , Venkatesh, Sudhakar K , Yin, Meng , Chen, Jun , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | August 12, 2017 | Volume: 47 | Issue: 4 | Pages: 976-987

10.1002/jmri.25818 Get It

PurposeTo assess the success rate, image quality, and the ability to stage liver fibrosis of a standard 2D gradient‐recalled echo (GRE) and four different spin‐echo (SE) magnetic resonance elastography (MRE) sequences in patients with different liver iron concentrations.Materials and MethodsA total of 332 patients who underwent 3T MRE examinations that included liver fat and iron quantification were enrolled, including 136 patients with all five MRE techniques. Thirty‐four patients had biopsy results for fibrosis staging. The liver stiffness, region of interest area, image quality, and success rate of the five sequences were compared in 115/136 patients. The area under the receiver operating characteristic curves (AUCs) and the accuracies for diagnosing early‐stage fibrosis and advanced fibrosis were compared. The effect of BMI (body mass index), the R2* relaxation time, and fat fraction on the image quality and liver stiffness measurements were analyzed.ResultsThe success rates were significantly higher in the four SE sequences (99.1–100%) compared with GRE MRE (85.3%) (all P < 0.001). There were significant differences of the mean ROI area between every pair of sequences (all P < 0.0001). There were no significant differences in the AUC of the five MRE sequences for discriminating advanced fibrosis (10 P‐values ranging from 0.2410–0.9171). R2* had a significant effect on the success rate and image quality for the noniron 2D echo‐planar imaging (EPI), 3D EPI and 2D GRE (all P < 0.001) sequences. BMI had a significant effect on the iron 2D EPI (P = 0.0230) and iron 2D SE (P = 0.0040) sequences.ConclusionAll five techniques showed good diagnostic performance in staging liver fibrosis. The SE MRE sequences had higher success rates and better image quality than GRE MRE in 3T clinical hepatic imaging.Level of Evidence: 3Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2018;47:976–987.
Quantitative assessment of lung stiffness in patients with interstitial lung disease using MR elastography
Marinelli, John P. , Levin, David L. , Hubmayr, Rolf D., McGee, Kiaran P. , Vassallo, Robert , Carter, Rickey E. , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | July 13, 2017 | Volume: 46 | Issue: 2 | Pages: No page available

10.1002/jmri.25805 Get It

PurposeTo investigate the use of magnetic resonance elastography (MRE) in the quantitative assessment of pulmonary fibrosis by comparing quantitative shear stiffness measurements of lung parenchyma in patients diagnosed with fibrotic interstitial lung disease (ILD) and healthy controls.Materials and MethodsA 1.5T spin‐echo, echo planar imaging MRE (SE‐EPI MRE) pulse sequence was utilized to assess absolute lung shear stiffness in 15 patients with diagnosed ILD and in 11 healthy controls. Data were collected at residual volume (RV) and total lung capacity (TLC). Spirometry data were obtained immediately prior to scanning. To test for statistical significance between RV and TLC shear stiffness estimates a two‐sample t‐test was performed. To assess variability within individual subject shear stiffness estimates, the intraclass correlation coefficient (ICC) and Krippendorff's alpha were calculated.ResultsPatients with ILD exhibited an average (±1 standard deviation) shear stiffness of 2.74 (±0.896) kPa at TLC and 1.32 (±0.300) kPa at RV. The corresponding values for healthy individuals were 1.33 (±0.195) kPa and 0.849 (±0.250) kPa, respectively. The difference in shear stiffness between RV and TLC was statistically significant (P < 0.001). At TLC, the ICC and alpha values were 0.909 and 0.887, respectively. At RV, the ICC and alpha values were 0.852 and 0.862, respectively.ConclusionIn subjects with known fibrotic interstitial lung disease, parenchymal shear stiffness is increased when compared to normal controls at both RV and TLC, with TLC demonstrating the most significant difference. MRE‐derived parenchymal shear stiffness is a promising new noninvasive imaging‐based biomarker of interstitial lung disease.Level of Evidence:1J. MAGN. RESON. IMAGING 2017;46:1–1
MR Elastography Demonstrates Unique Regional Brain Stiffness Patterns in Dementias
ElSheikh, Mona M., Arani, Arvin , Perry, Avital , Meyer, Fredric B. , Savica, Rodolfo , ElSheikh, Mona, Boeve, Bradley F. , Ehman, Richard L. , Huston, John , Arani, Arvin

American Journal of Roentgenology | June 1, 2017 | Volume: 209 | Issue: 2 | Pages: 403-408

10.2214/ajr.16.17455 Get It

Repeatability of MR Elastography of Liver: A Meta-Analysis
Serai, Suraj D. , Obuchowski, Nancy A. , Venkatesh, Sudhakar K. , Miller, Frank H. , Ashton, Edward, Cole, Patricia E., Sirlin, Claude B. , Ehman, Richard L. , Venkatesh, Sudhakar K , Serai, Suraj D , Miller, Frank H

Radiology | May 22, 2017 | Volume: 285 | Issue: 1 | Pages: 92-100

10.1148/radiol.2017161398 Get It

Magnetic resonance elastography measured shear stiffness as a biomarker of fibrosis in pediatric nonalcoholic fatty liver disease
Schwimmer, Jeffrey B. , Behling, Cynthia , Angeles, Jorge E., Paiz, Melissa, Durelle, Janis, Africa, Jonathan A. , Newton, Kimberly P. , Brunt, Elizabeth M. , Lavine, Joel E. , Abrams, Stephanie H., Masand, Prakash, Krishnamurthy, Rajesh , Wong, Kelvin, Yin, Meng , Glaser, Kevin J. , Wolfson, Tanya, Gamst, Anthony, Hooker, Jonathan , Haufe, William, Schlein, Alexandra , Hamilton, Gavin , Middleton, Michael S. , Dzyubak, Bogdan , Ehman, Richard L. , Hamilton, Gavin , Sirlin, Claude B. , Schwimmer, Jeffrey B , Yin, Meng

Hepatology | May 11, 2017 | Volume: 66 | Issue: 5 | Pages: 1474-1485

10.1002/hep.29241 Get It

Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two‐dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross‐validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross‐validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%‐81.1%). Overall cross‐validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%‐94.5%) for center 1, 90.0% (95% CI, 81.9%‐95.3%) for center 2, and 86.7% (95% CI, 77.9%‐92.9%) for automated analysis. Conclusion : 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (H epatology 2017;66:1474–1485)
Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
Arani, Arvin , Min, Hoon‐Ki , Fattahi, Nikoo , Wetjen, Nicholas M. , Trzasko, Joshua D. , Jack, Clifford R. , Lee, Kendall H. , Min, Hoon-Ki Paul , Manduca, Armando , Ehman, Richard L. , Huston, John , Jack, Clifford R , Arani, Arvin

Magnetic Resonance in Medicine | May 10, 2017 | Volume: 79 | Issue: 2 | Pages: 1043-1051

10.1002/mrm.26738 Get It

PurposeThe homeostasis of intracranial pressure (ICP) is of paramount importance for maintaining normal brain function. A noninvasive technique capable of making direct measurements of ICP currently does not exist. MR elastography (MRE) is capable of noninvasively measuring brain tissue stiffness in vivo, and may act as a surrogate to measure ICP. The objective of this study was to investigate the impact of changing ICP on brain stiffness using MRE in a swine model.MethodsBaseline MRE measurements were obtained, and then catheters were surgically placed into the left and right lateral ventricles of three animals. ICP was systematically increased over the range of 0 to 55 millimeters mercury (mmHg), and stiffness measurements were made using brain MRE at vibration frequencies of 60 hertz (Hz), 90 Hz, 120 Hz, and 150 Hz.ResultsA significant linear correlation between stiffness and ICP in the cross‐subject comparison was observed for all tested vibrational frequencies (P ≤ 0.01). The 120 Hz (0.030 ± 0.004 kilopascal (kPa)/mmHg, P < 0.0001) and 150 Hz (0.031 ± 0.008 kPa/mmHg, P = 0.01) vibrational frequencies had nearly identical slopes, which were approximately two‐ to three‐fold higher than the 90 Hz (0.017 ± 0.002 kPa/mmHg, P < 0.0001) and 60 Hz (0.009 ± 0.002 kPa/mmHg, P = 0.001) slopes, respectively.ConclusionIn this study, MRE demonstrated the potential for noninvasive measurement of changes in ICP. Magn Reson Med 79:1043–1051, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.