Back to Authors

Jannetto, Paul J.

https://orcid.org/0000-0002-5629-439X

Mayo Clinic

Mayo Clinic

Citations 76

Performance Comparison of Liquid Chromatography and Paper Spray Ionization with Mass Spectrometry for Measuring Kinase Inhibitors in Human Plasma
Lahr, Richard G. , Meyer, M. Joseph, Nelson, Leah , Kottschade, Lisa A. , Jannetto, Paul J. , Yang, Yifei , Meyer, Makenzie, Yang, Yifei K , Meyer, Makenzie, Nelson, Leah

ACS Pharmacology & Translational Science | January 16, 2025 | Volume: 8 | Issue: 2 | Pages: 557-565

10.1021/acsptsci.4c00646 Get It

AI-Augmented Kidney Stone Composition Analysis with Auto-Release Improves Quality, Efficiency, Cost–Effectiveness, and Staff Satisfaction
Day, Patrick L. , Rokke, Denise, Schneider, Laura, Abbott, Jillian, Holmen, Brenda, Wieczorek, Mikolaj A. , Carter, Rickey E. , Bornhorst, Joshua A. , Jannetto, Paul J. , Johnson, Patrick, Carter, Rickey E , Bornhorst, Joshua , Day, Patrick , Schneider, Laura, Holmen, Brenda, Johnson, Patrick W. , Kunze, Katie L.

The Journal of Applied Laboratory Medicine | December 19, 2024 | Volume: 10 | Issue: 2 | Pages: 305-314

10.1093/jalm/jfae146 Get It

Abstract Background We sought to evaluate key performance indicators related to an internally developed and deployed artificial intelligence (AI)-augmented kidney stone composition test system for potential improvements in test quality, efficiency, cost-effectiveness, and staff satisfaction. Methods We compared quality, efficiency, staff satisfaction, and financial data from the 6 months after the AI-augmented laboratory test system was deployed (test period) with data from the same 6-month period in the previous year (control period) to determine if AI-augmentation improved key performance indicators of this laboratory test. Results In the 6 months following the deployment (test period) of the AI-augmented kidney stone composition test system, 44 830 kidney stones were analyzed. Of these, 92% of kidney stones were eligible for AI-assisted interpretation. Out of these AI-eligible stones, 45% were able to be auto-released by the AI-augmented test system without human secondary review. Furthermore, the new AI-augmented kidney stone test system resulted in an apparent 40% reduction in incorrect laboratory results. Additionally, the new AI-augmented test system improved laboratory efficiency by 20%, improved staff satisfaction, and reduced the average analysis cost per kidney stone by $0.23. Conclusions The AI-augmented test system improved test quality, efficiency, cost-effectiveness and staff satisfaction related to this kidney stone composition test.
B-273 Clinical Validation of a Novel Lateral Flow Assay for Rapid and Sensitive Urine Fentanyl Screening
Vila, D Unsihuay, Butler, William E. , Jannetto, Paul J. , Xia, Xi , Vila, D M Unsihuay, Butler, W, Xia, X, Wang, Ping

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.630 Get It

Abstract Background The urgent need for rapid fentanyl detection at the point-of-care originates from its involvement in a high number of overdose deaths, primarily due to illicit use. Given fentanyl's potency compared to traditional opioids, accurate and sensitive detection is critical. Current lateral flow assays (LFA) cannot detect single-digit concentrations and may yield false negatives due to their lower sensitivity. Herein, we evaluate the clinical performance of a novel LFA (InstaStrip Fentanyl Rapid Test (urine)) with 1 ng/mL cutoff for fentanyl and no cross-reactivity for norfentanyl, offering enhanced sensitivity for effective overdose prevention at the ED. Methods A total of 172 urine samples submitted for UDS analysis were used for comparison studies. Fentanyl concentrations were categorized in 5 groups to cover various concentration categories around the cutoff of the LFA (1 ng/mL). These categories are: drug-free (<0.1 ng/mL, n=68), 0.1-0.5 ng/mL (n=14), 0.5-0.9 ng/mL (n=15), 1-1.5 ng/mL (n=9) and > 1.5 ng/mL (n= 66). Concentrations were determined by in-house LC-MS/MS methods validated according to CLIA standards, with fentanyl concentrations quantitated in the ABSciex software. For LFA testing, 150 μL of urine was added to a reagent tube containing dried rabbit anti-fentanyl antibody conjugated gold nanoparticles. After 20 sec of brief shaking, a test strip was inserted into the test tube. After 5 min, qualitative results were read as follow: both the control and test lines were visible in negative results, whereas only the control lines were visible in positive results. Method comparison study of the LFA was conducted by three operators who were blinded to the LC-MS/MS results. Result comparisons were made between the LFA strip and LC-MS/MS results, as well as among different operators for the same samples. Results Of the 75 urine samples with LC-MS/MS fentanyl concentrations ≥ 1 ng/mL, 74 produced consistently positive results using the InstaStrip Fentanyl Rapid Test. Of the 97 urine samples with LC-MS/MS fentanyl concentrations < 1 ng/mL, 96 produced consistently negative results using the InstaStrip Fentanyl Rapid Test. Using the LC-MS/MS as the gold standard method and 1 ng/mL as a cutoff, the clinical sensitivity of InstaStrip Fentanyl Rapid Test was calculated to be 98.67% (95% confidence interval (CI) 92.79-99.97%), and the clinical specificity was 98.97% (95% CI 94.39-99.97%). Consistent results among three operators were obtained for 100% of the “drug free”, “0.1- 0.5 ng/mL” and > 1.5 ng/mL groups, whereas 93.3 % (14 out of 15) and 88.9% (7 out of 8) were obtained for the “0.5-0.9 ng/mL” and “1-1.5 ng/mL” groups, respectively. The two samples with a singlet discrepant result (1 false positive and 1 false negative) in the triplicate experiments contained fentanyl concentrations of 0.9 and 1.0 ng/mL respectively, which are very close to the cutoff value. Conclusions In this study, the InstaStrip Fentanyl Rapid Test (urine) demonstrated high clinical sensitivity (98.67%), high specificity (98.97%) and high reproducibility showing that it may be useful in screening and identifying patients with fentanyl overdose in minutes in an emergency setting. This would facilitate appropriate patient triaging for optimal clinical care.
B-291 Validation of a Simple Qualitative Immunoassay for 21 Drugs of Abuse in Meconium on a Single Biochip Array
Lahr, Richard G. , Lightfoot, Alison, Langman, L, Jannetto, Paul J. , Sharma, Pragya

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.648 Get It

Abstract Background Drugs use during pregnancy is a major social and medical issue, which may lead to significant pre- and post-natal complications, such as preterm birth and newborn mortality. Exposed newborns may have long-term behavioral, cognitive, and developmental problems. Accurate detection of in utero drug exposure is crucial for timely medical intervention for the newborn and the mother. Meconium is the ‘gold standard' matrix for detection of drugs in newborn which reflects drug exposure during pregnancy. This study aims to develop and optimize a clinical assay for simultaneous screening of 21 drugs in meconium using a custom biochip array. Methods Custom biochip array (Randox Laboratories Ltd.) included 21 discrete test regions (DTRs) for amphetamine, methamphetamine, opioids/opiates (targeting morphine, oxymorphone, oxycodone, hydrocodone, 6-monoacetyl morphine, tramadol, buprenorphine, fentanyl, and methadone), phencyclidine (PCP), cocaine (targeting benzoylecgonine), benzodiazepines (targeting oxazepam, lorazepam, and clonazepam), zolpidem, barbiturates (targeting phenobarbital), ethyl glucuronide, methylphenidate, and marijuana metabolite (targeting Delta-9-Carboxy-Tetrahydrocannabinol [THC-COOH]). Patient samples were obtained from the residual meconium samples that had been previously used for other tests. Blank meconium samples were spiked at in-house cutoff, negative and positive assay control levels. All samples were extracted in specimen diluent using Biotage® Lysera and centrifuged. The supernatant was analyzed on a fully automated Randox Evidence+® Analyzer. A robotic arm pipetted 60 µL sample on to a biochip and then the analyzer performed a competitive chemiluminescent immunoassay. The results were generated as relative light units (RLUs). Results The sample results were determined to be “positive” or “negative” based on average RLU of cutoff controls for each analyte on an assay. The intra-assay (CV ≤ 15%) and inter-assay (CV ≤ 18%) precision was 100% agreement for positive and negative controls and there was no observed carryover for any of the analytes. The sample recovery was excellent with minimal to no matrix suppression for all analytes. Accuracy was performed by comparing spiked analyte results from Randox Evidence+® Analyzer with the expected results and all the spiked samples matched (positive or negative). When authentic patient or spiked results were compared with external laboratory test results, some discordant results were obtained. However, the discrepancies could be explained based on the different cutoffs (e.g., the Randox assay had lower cutoffs) or the known assay cross reactivities within the analytes of same class. These deviations did not affect clinical utility of the assay. Conclusions We validated a novel and simple qualitative chemiluminescent immunoassay in meconium using a custom biochip array. Unlike other routine screening/ELISA methods, which require separate assays for detection of similar drug targets, the custom biochip array offers a convenient, rapid and efficient method that utilizes only a single sample preparation for the screening of all 21 drug targets. Therefore, this technology has potential to be utilized as high-throughput screening assay. Like all qualitative assays, the limitation of this test is that all positive results will need to be assessed quantitatively for a definitive interpretation.
Total Copper and Labile Bound Copper Fraction as a Selective and Sensitive Tool in the Evaluation of Wilson Disease
Bornhorst, Joshua A. , Bitzer, Anna C, Day, Patrick L. , Wermers, Michelle, Smith, Carin Y. , Pazdernik, Vanessa K, Pelto, Ryan, Sankaran, Banu, Quicquaro, Adam Michael , Jannetto, Paul J. , Smith, Carin Y , Day, Patrick , Bornhorst, Joshua , Pazdernik, Vanessa K

The Journal of Applied Laboratory Medicine | September 3, 2024 | Volume: 9 | Issue: 6 | Pages: 1014-1027

10.1093/jalm/jfae090 Get It

Abstract Background A dual filtration-based method for determination of serum labile bound copper (LBC) and LBC fraction (LBC/total copper) was developed. Reduced total copper, elevated LBC, and elevated LBC fraction have been reported in Wilson disease (WD). Methods To evaluate the diagnostic performance of these markers, samples were obtained from 21 WD treatment-naïve (WD-TN, no WD treatment or <28 days of treatment) patients, 46 WD standard-of-care–treated (WD-SOC) patients, along with 246 patients representing other potential disorders of copper status. These were then compared to 213 reference interval population patients. Results Receiver operating characteristic curves for the reference population vs WD-TN yielded areas under the curve for total copper, LBC, and LBC fraction, of 0.99, 0.81, and 0.98, respectively. Using Youden cutoffs, sensitivity/specificity for WD-TN was 95%/97% for total copper, 71%/85% for LBC, and 95%/94% for LBC fraction. LBC values, but not total copper and LBC fraction, differed substantially between WD-TN and WD-SOC cohorts. We propose a dual model wherein total copper and LBC fraction results must agree to be classified as a “positive” or “negative” result for WD. This correctly classified 19/21 WD-TN patients as positive, and 194/213 reference interval patients as negative. The remaining “indeterminate” patients (representing approximately 9% of the reference and the WD-TN populations) exhibited conflicting total copper and LBC fraction results. When indeterminate results are excluded, this model exhibited apparent 100% sensitivity/specificity. Conclusions Agreement of total serum copper and LBC fraction classification may constitute an effective “rule-in” and “rule-out” assessment for WD-TN patients.
Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination
Bitzer, Anna C, Jannetto, Paul J. , Bornhorst, Joshua A. , Bornhorst, Joshua

Laboratory Medicine | August 13, 2024 | Volume: 56 | Issue: 1 | Pages: 64-69

10.1093/labmed/lmae067 Get It

Abstract Background Due to the ability of metal ions to cross the blood–brain barrier, there has been interest in analyzing cerebrospinal fluid (CSF) for trace element concentrations to investigate possible correlations with neurodegenerative diseases. In this study, Sarstedt polypropylene CSF collection tubes were analyzed to determine the contamination levels of aluminum, titanium, chromium, manganese, cobalt, nickel, molybdenum, gadolinium, vanadium, arsenic, cadmium, mercury, lead, thallium, selenium, copper, zinc, and iron. Methods Sarstedt polypropylene CSF collection tubes from 2 separate lots (n = 10 per lot) were filled with a 2 mL aliquot of a CSF pool with known element concentrations. After 24 hours of leaching at room temperature, all 18 elements were analyzed via inductively coupled plasma mass spectrometry (ICP-MS). Results were subtracted from the initial pool concentration to determine contamination levels. Results No detectable contamination above the assay limit of detection was found in 11 analytes. Molybdenum and selenium contamination was measured in all tubes, and aluminum, titanium, manganese, thallium, and zinc had minimal levels of sporadic detectable contamination in 25% or fewer of the tubes tested. Conclusions Sarstedt polypropylene CSF tubes are an acceptable collection tube for the analysis of most assessed metals in CSF.
Characterization of the alcohol biomarker phosphatidylethanol in donor whole blood and apheresis red blood cells: Implications for transfusion recipients
Kinard, Theresa N. , Alegria, Kathy N., Langman, Loralie J., Jannetto, Paul J. , Snozek, Christine L.H. , Sharma, Pragya, Sharma, Pragya

Transfusion | July 9, 2024 | Volume: 64 | Issue: 9 | Pages: 1617-1622

10.1111/trf.17942 Get It

AbstractIntroductionPhosphatidylethanol (PEth) is a long‐term marker of alcohol consumption used frequently in clinical scenarios such as liver transplant evaluation. Recent cases have demonstrated that packed red blood cell (pRBC) transfusion creates the potential for artificial elevation or decrease of observed PEth concentrations in recipients. Very little is known about the prevalence or stability of PEth in pRBCs.MethodsApheresis and whole‐blood (WB) donations were tested for PEth using liquid chromatography – tandem mass spectrometry with limit of quantitation 10 ng/mL. Units were stored under routine blood bank conditions to evaluate the stability of PEth and the impact of irradiation.ResultsOver 40% of apheresis and WB donors had PEth ≥10 ng/mL (maximum observed 587 ng/mL). As WB units were processed into component pRBCs, PEth concentrations increased and were higher than donor WB levels (EDTA sample) prior to collection (maximum observed 711 ng/mL). Storage for up to 5 weeks post donation resulted in mean 17.3% decrease in PEth‐positive units; in contrast to a prior report, we observed no PEth formation in units with negative (<10 ng/mL) baseline concentrations. Irradiation of pRBCs did not substantially affect PEth concentrations in either PEth‐positive or PEth‐negative units.DiscussionPEth concentrations in healthy blood donors may potentially confound alcohol use or abstinence assessment in pRBC recipients. Transfusion medicine services and clinical practices such as transplantation and behavioral medicine should recognize this phenomenon and collaborate on testing protocols to appropriately interpret PEth in pRBC recipients.
Use of the DMAIC Lean Six Sigma quality improvement framework to improve beta-lactam antibiotic adequacy in the critically ill
Wessel, Rebecca J , Ausman, Sara E., Martin, Nathaniel, Braga, Shienna , Hagy, Natalie, Moreland-Head, Lindsay N, Saleh, Omar Abu , Jannetto, Paul J. , Frazee, Erin N. , Braga, Shienna A, Hagy, Natalie T, Abu Saleh, Omar M, Rivera, Christina G. , Ausman, Sara E , Gajic, Ognjen

International Journal for Quality in Health Care | July 2, 2024 | Volume: 36 | Issue: 3 | Pages: No page available

10.1093/intqhc/mzae062 Get It

Abstract Beta-lactam antibiotics are widely used in the intensive care unit due to their favorable effectiveness and safety profiles. Beta-lactams given to patients with sepsis must be delivered as soon as possible after infection recognition (early), treat the suspected organism (appropriate), and be administered at a dose that eradicates the infection (adequate). Early and appropriate antibiotic delivery occurs in &gt;90% of patients, but less than half of patients with sepsis achieve adequate antibiotic exposure. This project aimed to address this quality gap and improve beta-lactam adequacy using the Define, Measure, Analyze, Improve, and Control Lean Six Sigma quality improvement framework. A multidisciplinary steering committee was formed, which completed a stakeholder analysis to define the gap in practice. An Ishikawa cause and effect (Fishbone) diagram was used to identify the root causes and an impact/effort grid facilitated prioritization of interventions. An intervention that included bundled education with the use of therapeutic drug monitoring (TDM; i.e. drug-level testing) was projected to have the highest impact relative to the amount of effort and selected to address beta-lactam inadequacy in the critically ill. The education and TDM intervention were deployed through a Plan, Do, Study, Act cycle. In the 3 months after “go-live,” 54 episodes of beta-lactam TDM occurred in 41 unique intensive care unit patients. The primary quality metric of beta-lactam adequacy was achieved in 94% of individuals after the intervention. Ninety-four percent of clinicians gauged the education provided as sufficient. The primary counterbalance of antimicrobial days of therapy, a core antimicrobial stewardship metric, was unchanged over time (favorable result; P = .73). Application of the Define, Measure, Analyze, Improve, and Control Lean Six Sigma quality improvement framework effectively improved beta-lactam adequacy in critically ill patients. The approach taken in this quality improvement project is widely generalizable to other drugs, drug classes, or settings to increase the adequacy of drug exposure.
High Lead Levels in 2 Independent and Authenticated Locks of Beethoven’s Hair
Rifai, Nader , Brown, Kevin E., Erdahl, Sarah A , Jannetto, Paul J. , Meredith, William

Clinical Chemistry | May 6, 2024 | Volume: 70 | Issue: 6 | Pages: 878-879

10.1093/clinchem/hvae054 Get It

Rapid and Sensitive Detection of Fentanyl and Its Analogs by a Novel Chemiluminescence Immunoassay
Zhao, Jiangyang , Uddin, Mezbah, Unsihuay, Daisy , Butler, William E. , Xia, Terrance W., Xu, Jayson Z., Sheng, Xiaolin , Jannetto, Paul J. , Xia, Xiao‐Feng , Butler, William, Wang, Simon, Wang, Ping

Clinical Chemistry | April 22, 2024 | Volume: 70 | Issue: 7 | Pages: 978-986

10.1093/clinchem/hvae071 Get It

Abstract Background Abuse of fentanyl and its analogs is a major contributor to the opioid overdose epidemic in the United States, but detecting and quantifying trace amounts of such drugs remains a challenge without resorting to sophisticated mass spectrometry-based methods. Methods A sensitive immunoassay with a sub-picogram limit of detection for fentanyl and a wide range of fentanyl analogs has been developed, using a novel high-affinity antibody fused with NanoLuc, a small-size luciferase that can emit strong and stable luminescence. When used with human urine samples, the assay has a sub-picogram limit of detection for fentanyl, with results fully concordant with LC-MS. Results When applied to clinical samples, the novel chemiluminescence immunoassay can detect low positive fentanyl missed by routine screening immunoassays, with a limit of detection of 0.8 pg/mL in human urine. When applied to environmental samples, the assay can detect levels as low as 0.25 pg fentanyl per inch2 of environment surface. Assay turnaround time is less than 1 h, with inexpensive equipment and the potential for high-throughput automation or in-field screening. Conclusions We have established a novel assay that may have broad applications in clinical, environmental, occupational, and forensic scenarios for detection of trace amounts of fentanyl and its analogs.