Abstract Background Sarcoidosis is an infiltrative inflammatory condition affecting multiple organs, with cardiac involvement designated as cardiac sarcoidosis (CS). It has been proposed that inflammatory conditions like sarcoid increase the risk of venous thromboembolism (VTE), defined as pulmonary embolism (PE) and deep vein thrombosis (DVT) due to the hypercoagulable environment created by inflammation. Purpose Although previous studies have demonstrated an association with sarcoidosis and VTE, these studies failed to account for steroid use (crucial for sarcoid treatment) as an important confounder. Also, no major studies have been done previously assessing the risk of VTE in CS specifically. The objective of this investigation is to determine the association between CS, steroid treatment for CS, and VTE. Methods Patients referred to our institution with concern for sarcoid/CS were retrospectively assessed. Specific variables of interest including general baseline characteristics and those specific to CS were analyzed for their association with VTE development. Results Using Heart Rhythm Society guidelines, 649 patients were split into three categories: 235 with no sarcoid (NS), 91 with extra-cardiac sarcoid (ECS) only, and 323 with CS. In univariate analysis, 39 (12%) CS patients developed a PE vs 9 (4%) NS patients (OR 3.44, p=0.0003) and 44 (14%) CS patients developed DVT vs 18 (8%) NS patients (OR 1.90, p=0.02). In multivariate regression analysis however, neither CS nor ECS was an independent risk factor for VTE (p>0.05) but steroid use was a strong predictor of VTE (HR 3.12, p=0.007 for PE, HR 6.17, p<0.0001 for DVT). Also, steroid dose was found to be an independent predictor for both PE (p=0.001) and DVT (p=0.007) in a Cox proportionate hazards model (significance appeared at >17.5 mg daily on a receiver operating characteristic curve). Conclusion Contrary to previous studies, the current study found that neither sarcoidosis nor CS is an independent risk factor for VTE. Rather, steroid therapy for CS treatment leads to an increased prevalence of VTE, specifically at a dose above 17.5 mg daily. More research is required to clarify this relationship and assess the importance of steroid-sparing immunosuppressive therapy and potentially VTE prophylaxis in CS management. Steroid use and time to PE/DVT Funding Acknowledgement Type of funding source: None
Natural History of Patients Diagnosed with Cardiac Sarcoidosis at Left Ventricular Assist Device Implantation or Cardiac Transplantation
To our knowledge, natural history has not been reported for cardiac sarcoidosis (CS) diagnosed by pathologic evaluation of the apical core at left ventricular assist device (LVAD) implantation or cardiac transplantation. We retrospectively identified 232 consecutive patients meeting CS criteria. Of these patients, 54 were diagnosed by pathologic confirmation of CS, 10 after evaluation of the apical core (LVAD implant) or explanted heart (transplant). We compared clinical characteristics at initial evaluation and outcomes for these 10 patients with those of 10 patients with known CS before LVAD implant/transplant. In the study group, five patients (50%) had confirmed extracardiac sarcoidosis before LVAD implant/transplant; five had not been diagnosed with sarcoidosis. Mean (standard deviation) left ventricular ejection fraction at initial evaluation was 23% (16%), and left ventricular end-diastolic dimension was 61 (10) mm. Four patients died during follow-up; however, no survival difference was found for the 10 patients diagnosed incidentally and the group with a previous diagnosis or institutional LVAD/transplant cohorts. Patients diagnosed with CS on pathological examination of the apical core/explanted heart may have severe dilated cardiomyopathy as the initial presentation. Outcomes for patients with CS after advanced heart failure therapies may be comparable with those of non-CS patients.
Percutaneous Axillary Intra-aortic Balloon Pump Insertion Technique as Bridge to Advanced Heart Failure Therapy
In patients with advanced heart failure (HF), temporary mechanical circulator support (TMCS) is used to improve hemodynamics, via left ventricular unloading, and end-organ function as a bridge to definitive therapy. While listed for cardiac transplantation, use of TMCS may be prolonged, preventing adequate mobility. Here, we describe the technique for placement of a percutaneous axillary intra-aortic balloon pump (IABP) using single-site arterial access to facilitate ambulation and subsequent safe removal without surgery or a closure device. Retrospective review of the experience with this approach at a single institution between September 2017 and February 2020 documented feasibility and safety. Baseline demographics, hemodynamic data, and clinical outcomes were collected. Thirty-eight patients had a total of 56 IABPs placed. There were no significant access site or cerebrovascular complications. One fifth of IABPs (21.4%) had balloon failure or migration, requiring placement of a new device, though no patients had significant complications from balloon failure. The majority (81.6%) of patients in the cohort on axillary IABP support were ambulatory and ultimately received the intended therapy (63.2% transplant, 13.2% durable left ventricular assist device, 5.3% other cardiac surgery). Percutaneous, axillary IABP is feasible and associated with an acceptable complication rate as a bridge to definitive therapy.
Inadequate left ventricular unloading during ramp is associated with hospitalization or death during left ventricular assist device support
AbstractA combined right and left‐sided heart catheterization (RHC/LHC) protocol was recently reported to optimize patients supported by left ventricular assist device (LVAD). Using this platform, we sought to evaluate the prognostic significance of several hemodynamic indices, including left ventricular end‐diastolic pressure (LVEDP) and transaortic gradient (peak aortic pressure ‐ peak left ventricular pressure in systole, TAG). We evaluated all patients undergoing RHC/LHC at our institution from 2015 through 2018, and comprehensive clinical data were obtained. Primary end points were (1) a composite outcome that included hospitalization or death and (2) 1‐year overall survival after catheterization. Forty‐two patients were included in the analysis. Optimization resulted in normalization of hemodynamic parameters; all variables were significantly improved from baseline (P ≤ .05). On univariate modeling, final LVEDP was associated with the primary end point (hazard ratio [HR], 1.2 per 1‐mm Hg increase; 95% CI, 1.1‐1.3; P = .002). After adjusting for LVAD speed, TAG, and cardiac index in a multivariate model, the association between LVEDP and the composite end point remained significant (HR, 1.2 per 1‐mm Hg increase; 95% CI, 1.1‐1.4; P = .001). In the setting of LVAD support, inadequate LV unloading was a significant marker of poor outcomes with time, suggesting that LVEDP is a central prognostic marker in this population.
Correction of High Afterload Improves Low Cardiac Output in Patients Supported on Left Ventricular Assist Device Therapy
There is a paucity of data describing the invasive assessment of afterload and influence on cardiac output in patients supported on left ventricular assist device (LVAD) therapy. From 2015 to 2018, patients on LVAD therapy were evaluated with simultaneous left/right heart catheterization ramp study for speed optimization. Hemodynamic parameters from 31 patients without significant aortic insufficiency were analyzed. Mean central aortic pressure (MAP) was elevated at 87 ± 13 mm Hg at baseline. No direct association between MAP and cardiac index (CI) was found (r = 0.11, p = 0.20). However, variable MAP provided vastly different patterns of cardiac output response to speed increments (positive correlation, p = 0.047 for MAP <80 mm Hg; negative trend, p = 0.25 for MAP > 100 mm Hg). Patients noted to be hypertensive (MAP > 90, n = 8) received nitrate therapy and experienced both improvement in biventricular filling pressures and a mean increase in CI from 2.4 to 2.9 L/min/m2 (+22%, p = 0.04) at a fixed revolutions per minute. High afterload is common in patients on LVAD therapy, is associated with poor response to ramp, and is ameliorated by nitrates. These findings serve as a foundation to evaluate the dynamic effects of high afterload and chronic vasodilator therapy in patients with durable LVADs.
Dual RVAD-ECMO Circuits to Treat Cardiogenic Shock and Hypoxemia Due to Necrotizing Lung Infection: A Case Report
Utilization of venoarterial extracorporeal membrane oxygenation (VA-ECMO) is expanding, but dual VA-ECMO circuits to treat cardiogenic shock with refractory hypoxemia is unreported. We describe the case of combined cardiogenic and distributive shock due to necrotizing pulmonary blastomycosis. After initial central VA-ECMO cannulation, acute respiratory distress syndrome (ARDS) with increasing shunt resulted in significant central hypoxemia due to progressive ventilation-perfusion mismatch. An additional circuit provided complete oxygenation of the high circulating volume. After 4 months on support, he underwent successful heart-lung-kidney transplantation. Dual ECMO circuits are technically feasible and may be advantageous in specific circumstances of high pulmonary shunting resulting in excessive hypoxemia unbalanced with appropriate oxygen delivery.
P1805Troponin-T, NT-proBNP and creatinine at presentation predict outcomes in patients with cardiac sarcoidosis
Abstract Background Cardiac sarcoidosis (CS) is an infiltrative inflammatory condition defined by infiltration of noncaseating granulomas into the heart. Based on the location of sarcoid lesion involvement, patients can present with symptoms of congestive heart failure, arrhythmias, and even sudden cardiac death. Purpose Diagnosis of CS has been somewhat challenging, with the Heart Rhythm Society (HRS) and Japanese Ministry of Health and Welfare (JMHW) being the 2 widely accepted diagnostic guidelines. Endomyocardial biopsy is the gold standard to prove definite CS but has a low sensitivity. Imaging studies have been helpful as non-invasive methods to diagnose probable CS but these can be logistically difficult and expensive. Thus, investigating for laboratory biomarkers that can act as both diagnostic and prognostic can be crucial in how we diagnose and manage CS in the future. Methods Patients meeting HRS for CS were evaluated at a single institution (n=217). Biomarkers of interest included angiotensin-converting enzyme (ACE), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), N-terminal pro B-type natriuretic peptide (NT-proBNP), troponin-T, 1,25 dihydroxyvitamin D (1,25-OHVit-D), and creatinine. Biomarkers were stratified by clinical variables of interest and their association with prognosis was examined. The primary endpoint was LVAD implantation, transplantation, or death. Results Mean values on presentation were: ACE 32.9±28, ESR 12±13, CRP 7.4±19, NT-proBNP 1630±2923, Troponin-T 0.03±0.1, 1,25-OHVit-D 55.5±20, and creatinine 1.12±0.3. None of the biomarkers differed by sex, definite or probable CS, or a history of immunosuppression. ACE levels were associated with the presence of cardiac fibrosis on cardiac MRI (mean difference 14.7, p=0.032). Troponin-T (p=0.006; HR 1.06 per 0.01 ng/mL), NT-proBNP (p=0.0003; HR 1.31 per 1,000 pg/mL), and creatinine (p=0.01; HR 4.02 per mg/dL) were each associated with the primary endpoint (52/217 patients). Biomarkers associated with long term outcomes in patients with cardiac sarcoidosis Biomarker Hazard ratio P value Troponin-T 1.06 (1.02–1.11)* 0.006 NT-pro BNP 1.31 (1.15–1.48)** 0.0003 Creatinine 4.02 (1.41–9.94)*** 0.01 *Per 0.01 ng/mL change; 99th percentile upper reference limit <0.01 ng/mL; **per 1,000 pg/mL change; ***per 1 mg/dL change. Conclusion Troponin-T, NT-proBNP, and creatinine at presentation predict outcomes in patients with CS. Further investigation on the utility of biomarkers for assessment of disease activity and treatment response is warranted.
Exercise-induced hypoxemia predicts heart failure hospitalization and death in patients supported with left ventricular assist devices
Following implantation of continuous-flow left ventricular assist devices, mechanical off-loading results in improved resting hemodynamics; however, peak exercise capacity generally does not increase substantially. This study evaluated patients supported by continuous-flow left ventricular assist devices who were invasively monitored during exercise to define parameters that underpin exercise capacity and outcomes. A review of all patients supported by continuous-flow left ventricular assist devices who underwent supine bicycle ergometry exercise testing with measurement of pulmonary gas exchange during right heart catheterization for evaluation of dyspnea at one institution between 2007 and 2018 was performed (n = 22). The primary outcome of this investigation was death or heart failure hospitalization. Although resting filling pressures were relatively preserved, resting cardiac index (Fick) was low (2.1 ± 0.5 mL/kg/min). An impaired cardiac output reserve was present in 75% of patients. On univariate modeling, patients with supine exercise–induced hypoxemia (O 2 saturation <90%) experienced significantly diminished hospitalization-free survival (unadjusted hazard ratio = 11.0, confidence interval = 2.4–57.2, p = 0.003), which persisted despite adjustment for right heart catheterization peak VO 2 and peak cardiac output (adjusted hazard ratio = 25, confidence interval = 3.6–322, p = 0.001). Our findings suggest that supine exercise testing provides additional prognostic utility in the continuous-flow left ventricular assist device population.
Diastolic Pulmonary Gradient as a Predictor of Right Ventricular Failure After Left Ventricular Assist Device Implantation
Background Diastolic pulmonary gradient ( DPG ) was proposed as a better marker of pulmonary vascular remodeling compared with pulmonary vascular resistance ( PVR ) and transpulmonary gradient ( TPG ). The prognostic significance of DPG in patients requiring a left ventricular assist device ( LVAD ) remains unclear. We sought to investigate whether pre‐ LVAD DPG is a predictor of survival or right ventricular ( RV ) failure post‐ LVAD . Methods and Results We retrospectively reviewed 268 patients who underwent right heart catheterization before LVAD implantation from 2007 to 2017 and had pulmonary hypertension because of left heart disease. Patients were dichotomized using DPG ≥7 mm Hg, PVR ≥3 mm Hg, or TPG ≥12 mm Hg. The associations between these parameters and all‐cause mortality or RV failure post LVAD were assessed with Cox proportional hazards regression and Kaplan–Meier analyses. After a mean follow‐up time of 35 months, elevated DPG was associated with increased risk of RV failure (hazard ratio [ HR ]: 3.30; P =0.004, for DPG ≥7 versus DPG <7), whereas elevated PVR ( HR 1.85, P =0.13 for PVR ≥3 versus PVR <3) or TPG ( HR 1.47, P =0.35, for TPG ≥12 versus TPG <12) were not associated with the development of RV failure. Elevated DPG was not associated with mortality risk ( HR 1.16, P =0.54, for DPG ≥7 versus DPG <7), whereas elevated PVR , but not TPG , was associated with higher mortality risk ( HR 1.55; P =0.026, for PVR ≥3 versus PVR <3). Conclusions Among patients with pulmonary hypertension because of left heart disease requiring LVAD support, elevated DPG was associated with RV failure but not survival, while elevated PVR predicted mortality post LVAD implantation.
Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
Background Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cf LVADs ). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. Methods and Results To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cf LVAD was developed. Patients implanted with cf LVAD s underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient ( TAG ) was established. Thirty eight patients with cf LVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG . A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. Conclusions Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cf LVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading.