Back to Authors

Hanssen, Arlen D.

https://orcid.org/0000-0001-8093-1777

Mayo Clinic

Mayo Clinic

Citations 68

Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection
Cazanave, Charles , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Urena, Eric O. Gomez, Mandrekar, Jayawant N. , Osmon, Douglas R. , Lough, Lindsay E., Pritt, Bobbi S. , Steckelberg, James M., Patel, Robin , Patel, Robin , Pritt, Bobbi S

Journal of Clinical Microbiology | May 9, 2013 | Volume: 51 | Issue: 7 | Pages: 2280-2287

10.1128/jcm.00335-13 Get It

ABSTRACT We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee ( n = 272) or hip ( n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture ( P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure.
Executive Summary: Diagnosis and Management of Prosthetic Joint Infection: Clinical Practice Guidelines by the Infectious Diseases Society of Americaa
Osmon, Douglas R. , Berbari, Elie F. , Berendt, Anthony R., Lew, Daniel , Zimmerli, Werner, Steckelberg, James M., Rao, Nalini, Hanssen, Arlen D. , Wilson, Walter R.

Clinical Infectious Diseases | December 10, 2012 | Volume: 56 | Issue: 1 | Pages: 1-10

10.1093/cid/cis966 Get It

Abstract These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.
Diagnosis and Management of Prosthetic Joint Infection: Clinical Practice Guidelines by the Infectious Diseases Society of Americaa
Osmon, Douglas R. , Berbari, Elie F. , Berendt, Anthony R., Lew, Daniel , Zimmerli, Werner, Steckelberg, James M., Rao, Nalini, Hanssen, Arlen D. , Wilson, Walter R.

Clinical Infectious Diseases | December 8, 2012 | Volume: 56 | Issue: 1 | Pages: e1-e25

10.1093/cid/cis803 Get It

Abstract These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.
Prosthetic Joint Infection Diagnosis Using Broad-Range PCR of Biofilms Dislodged from Knee and Hip Arthroplasty Surfaces Using Sonication
Gomez, Eric, Cazanave, Charles , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Steckelberg, James M., Uhl, James R., Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Osmon, Douglas R. , Berbari, Elie F. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | August 16, 2012 | Volume: 50 | Issue: 11 | Pages: 3501-3508

10.1128/jcm.00834-12 Get It

ABSTRACT Periprosthetic tissue and/or synovial fluid PCR has been previously studied for prosthetic joint infection (PJI) diagnosis; however, few studies have assessed the utility of PCR on biofilms dislodged from the surface of explanted arthroplasties using vortexing and sonication (i.e., sonicate fluid PCR). We compared sonicate fluid 16S rRNA gene real-time PCR and sequencing to culture of synovial fluid, tissue, and sonicate fluid for the microbiologic diagnosis of PJI. PCR sequences generating mixed chromatograms were decatenated using RipSeq Mixed. We studied sonicate fluids from 135 and 231 subjects with PJI and aseptic failure, respectively. Synovial fluid, tissue, and sonicate fluid culture and sonicate fluid PCR had similar sensitivities (64.7, 70.4, 72.6, and 70.4%, respectively; P > 0.05) and specificities (96.9, 98.7, 98.3, and 97.8%, respectively; P > 0.05). Combining sonicate fluid culture and PCR, the sensitivity was higher (78.5%, P < 0.05) than those of individual tests, with similar specificity (97.0%). Thirteen subjects had positive sonicate fluid culture but negative PCR, and 11 had negative sonicate fluid culture but positive PCR (among which 7 had prior use of antimicrobials). Broad-range PCR and culture of sonicate fluid have equivalent performance for PJI diagnosis.
Corynebacterium Prosthetic Joint Infection
Cazanave, Charles , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | February 15, 2012 | Volume: 50 | Issue: 5 | Pages: 1518-1523

10.1128/jcm.06439-11 Get It

ABSTRACT Identification of Corynebacterium species may be challenging. Corynebacterium species are occasional causes of prosthetic joint infection (PJI), but few data are available on the subject. Based on the literature, C. amycolatum , C. aurimucosum , C. jeikeium , and C. striatum are the most common Corynebacterium species that cause PJI. We designed a rapid PCR assay to detect the most common human Corynebacterium species, with a specific focus on PJI. A polyphosphate kinase gene identified using whole-genome sequence was targeted. The assay differentiates the antibiotic-resistant species C. jeikeium and C. urealyticum from other species in a single assay. The assay was applied to a collection of human Corynebacterium isolates from multiple clinical sources, and clinically relevant species were detected. The assay was then tested on Corynebacterium isolates specifically associated with PJI; all were detected. We also describe the first case of C. simulans PJI.
Proximal femoral allograft-prosthesis composites in revision hip replacement
Sakellariou, Vasileios I. , Hanssen, Arlen D. , Sim, Franklin H. , Babis, George C. , O’Connor, Mary I.

The Journal of Bone and Joint Surgery. British volume | March 1, 2010 | Volume: 92-B | Issue: 3 | Pages: 349-355

10.1302/0301-620x.92b3.23112 Get It

We report the use of an allograft prosthetic composite for reconstruction of the skeletal defect in complex revision total hip replacement for severe proximal femoral bone loss. Between 1986 and 1999, 72 patients (20 men, 52 women) with a mean age of 59.9 years (38 to 78) underwent reconstruction using this technique. At a mean follow-up of 12 years (8 to 20) 57 patients were alive, 14 had died and one was lost to follow-up. Further revision was performed in 19 hips at a mean of 44.5 months (11 to 153) post-operatively. Causes of failure were aseptic loosening in four, allograft resorption in three, allograft nonunion in two, allograft fracture in four, fracture of the stem in one, and deep infection in five. The survivorship of the allograft-prosthesis composite at ten years was 69.0% (95% confidence interval 67.7 to 70.3) with 26 patients remaining at risk. Survivorship was statistically significantly affected by the severity of the pre-operative bone loss (Paprosky type IV; p = 0.019), the number of previous hip revisions exceeding two (p = 0.047), and the length of the allograft used (p = 0.005).
Sonication of Explanted Prosthetic Components in Bags for Diagnosis of Prosthetic Joint Infection Is Associated with Risk of Contamination
Trampuž, Andrej , Piper, Kerryl E., Hanssen, Arlen D. , Osmon, Douglas R. , Cockerill, Franklin R., Steckelberg, James M., Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | February 2, 2006 | Volume: 44 | Issue: 2 | Pages: 628-631

10.1128/jcm.44.2.628-631.2006 Get It

ABSTRACT Explanted orthopedic implants from 54 patients with aseptic failure and 24 patients with prosthetic knee or hip infection were sonicated in polyethylene bags. The sensitivities of periprosthetic tissue and sonicate fluid cultures for the diagnosis of prosthetic joint infection were 54% and 75%, whereas the specificities were 98% and 87%, respectively. Sonication in bags improved bacterial recovery from the surface of orthopedic implants; however, it lacked specificity, due to bag leakage.
icaA Is Not a Useful Diagnostic Marker for Prosthetic Joint Infection
Frank, Kristi L. , Hanssen, Arlen D. , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | October 7, 2004 | Volume: 42 | Issue: 10 | Pages: 4846-4849

10.1128/jcm.42.10.4846-4849.2004 Get It

ABSTRACT A collection of 99 staphylococcal isolates associated with prosthetic joint infection and 23 coagulase-negative staphylococci isolated from noninfected arthroplasty-associated specimens were screened in order to determine whether the presence of icaA could be used to distinguish between pathogens and nonpathogens. All Staphylococcus aureus prosthetic joint infection isolates ( n = 55) were icaA positive. A total of 46% (20 out of 44) of coagulase-negative staphylococcal prosthetic joint infection isolates were icaA positive, and 30% (7 out of 23) of arthroplasty-associated non-prosthetic joint infection-associated coagulase-negative staphylococcal isolates were icaA positive ( P = 0.23). Certain coagulase-negative Staphylococcus species appeared more likely to be isolated as either arthroplasty-associated non-prosthetic joint infection-associated isolates (e.g., Staphylococcus warneri and Staphylococcus hominis ) or pathogens (e.g., Staphylococcus lugdunensis ). The presence of icaA in a coagulase-negative staphylococcal isolate associated with an arthroplasty is not a useful diagnostic indicator of pathogenicity.