Back to Authors

Simonson, Julie A.

Mayo Clinic

Mayo Clinic in Arizona

Citations 3

Screen detection of serrated polyps by stool DNA multi-target testing (sDNA-MT): Comparison against fecal immunochemical occult blood testing (FIT).
Heigh, Russell I., Yab, Tracy C. , Simonson, Julie A., Boardman, Lisa A., Domanico, Michael J. , Lidgard, Graham P. , Ahlquist, David A. , Mahoney, Douglas W. , Boardman, Lisa A., Berger, Barry M.

Journal of Clinical Oncology | February 24, 2017 | Volume: 31 | Issue: 4_suppl | Pages: 341-341

10.1200/jco.2013.31.4_suppl.341 Get It

341 Background: Precursors to 1/3 of colorectal cancer (CRC), serrated polyps have historically been underdetected by screening due to their inconspicuous, nonhemorrhagic, and proximal nature. New generation sDNA-MT show high sensitivity for both CRC and advanced adenomas (Gastroenterology 2012;142:248), but screen detection of serrated polyps by this approach requires further validation. Aim: To assess and compare noninvasive detection of sessile serrated polyps >1cm (SSP) by sDNA-MT and a commercial quantitative FIT. Methods: In a blinded prospective study, a single stool sample used for both tests was collected from 456 asymptomatic adults prior to screening or surveillance colonoscopy (criterion standard). All 29 patients with SSP were included as cases and all 232 with no neoplastic findings as controls. Buffered stool samples were processed and frozen on receipt; Exact Sciences performed sDNA-MT in batches using optimized analytical methods (Gastroenterology 2012;142:S770). The sDNA-MT panel targets methylated BMP3 (mBMP3) and NDRG4, mutant KRAS, β-actin, and hemoglobin. FIT (Polymedco OC-FIT Check) was performed in separate lab <2 days post defecation and evaluated at cutoffs of 50 (FIT-50) and 100 ng/ml (FIT-100). Results: Age/sex distributions were similar in cases and controls: 40% vs 45% > 65 years and 51% vs 59% women, p=NS respectively. SSP median size was 1.2cm (range 1-3cm), 93% were proximal, and 64% had synchronous diminutive polyps. Among sDNA-MT markers, mBMP3 proved highly discriminant for SSP detection (AUC=0.87, p<0.00001); other DNA markers were less informative and provided no incremental sensitivity. Hemoglobin alone showed no discrimination (AUC=0.50, p=NS). At matched specificities, SSP detection by stool mBMP3 was significantly greater than by either FIT-50 or FIT-100 (Table). Conclusions: From a screening and surveillance setting, SSP can be detected noninvasively by stool assay of exfoliated DNA markers, especially mBMP3. FIT appears to have no value in SSP detection. [Table: see text]
Long-term Follow-up of Patients Having False-Positive Multitarget Stool DNA Tests after Negative Screening Colonoscopy: The LONG-HAUL Cohort Study
Cotter, Thomas G. , Burger, Kelli N. , Devens, Mary E., Simonson, Julie A., Lowrie, Kari L., Heigh, Russell I., Johnson, David H. , Ahlquist, David A. , Mahoney, Douglas W. , Kisiel, John B. , Cotter, T G

Cancer Epidemiology, Biomarkers & Prevention | December 20, 2016 | Volume: 26 | Issue: 4 | Pages: 614-621

10.1158/1055-9965.epi-16-0800 Get It

Abstract Background: Studies of colorectal cancer screening by multitarget stool DNA (MT-sDNA) show false-positive (FP) rates of 7% to 13%. It is unclear whether FP patients are at increased long-term risk of adverse outcomes. Methods: We compared subsequent clinical events among patients with apparent FP MT-sDNA with those in patients reported as true negative (TN). This was a retrospective cohort study of participants in pre-FDA approval MT-sDNA studies having nonadvanced or negative baseline colonoscopy findings from a single referral center. Per-protocol and calibrated cutoffs defined FP and TN groups. From the time of stool collection, we measured differences between FP and TN groups in time to death, subsequent cancer diagnosis, and onset of alarm symptoms. Results: Of 1,050 eligible patients, only 6 were lost to follow-up. Median age was 65.6 years [interquartile range (IQR), 56.8–72.3]; 54% were female. Median follow-up time was 4 years (IQR, 3.5–5.3). Eight aerodigestive (lung and gastrointestinal tract) cancers occurred. FP status by calibrated, but not per-protocol, cutoffs was associated with subsequent aerodigestive cancer; however, cumulative incidence did not exceed SEER expectations from the general population. By any cutoff method, FP status was not associated with mortality or alarm symptoms. Conclusions: Although FP status was associated with long-term aerodigestive cancers, new cases were not temporally related and did not exceed incidence estimates from general population. Impact: These observations do not justify aggressive follow-up evaluation for patients with FP MT-sDNA at this time. Larger studies are needed to confirm these early findings. Cancer Epidemiol Biomarkers Prev; 26(4); 614–21. ©2016 AACR.
Abstract B12: An optimized molecular stool test for colorectal cancer screening: Evaluation of an automated analytic platform and logistic algorithm
Lidgard, Graham P. , Domanico, Michael J. , Bruinsma, Janelle J., Light, James, Oldham-Haltom, Rebecca, Fourrier, Keith D. , Allawi, Hatim T. , Yab, Tracy C. , Simonson, Julie A., Devens, Mary E., Heigh, Russell I., Ahlquist, David A. , Gagrat, Zubin D. , Berger, Barry M.

Cancer Prevention Research | January 23, 2014 | Volume: 5 | Issue: 11_Supplement | Pages: B12-B12

10.1158/1940-6207.prev-12-b12 Get It

Abstract We have demonstrated that colorectal cancer (CRC) and advanced pre-cancers can be detected non-invasively by a manual multi-target stool DNA-based test (sDNA-MT) comprising exfoliated DNA markers (methylated BMP3 and NDRG4, mutant KRAS (7 mutations, codons 12, 13), plus β-actin) and fecal hemoglobin (Hb) (Lidgard, Gastroenterology 2012;142(5);S-770). We now report the clinical performance of this sDNA-MT test using an optimized automated analytic platform and logistic algorithm. This platform could facilitate the routine performance of sDNA-MT for CRC screening by molecular diagnostics capable clinical laboratories. Method: Stool samples were collected from 1003 subjects at 36 study sites after informed consent and prior to colonoscopy bowel preparation from those presenting for average risk CRC screening (283) or surveillance (176) at 2 sites. From referred subjects with CRC, Advanced Adenoma (AA) or Sessile Serrate Adenoma ≥ 1 cm, (SSA) stool was collected at least 7 days post-colonoscopy and prior to surgery or chemo-radiation (135; 21 sites) and similarly for subjects with no neoplastic findings on colonoscopy (Neg) (409; 13 sites). The study population included: cases (207), 58% male, median age 65 yrs. (38-87), CRC (93), AA (84), SSA ≥ 1 cm (30) and controls (796), 42% male, median age 65 yrs. (50-84), Neg (641) and non-advanced adenomas (NA) (155). Stool sample collection and DNA isolation were previously described. Automated methylation, mutation and actin assays were performed with a Hamilton STARlet fluid handler (Hamilton Robotics, Reno NV), and QuARTS (Quantitative Allele-specific Real-time Target and Signal amplification) run on an ABI 7500 FastDx real time thermal cycler (Applied Biosystems, Foster City, CA). Fecal Hb (ng/ml buffer) analysis was performed by automated sandwich ELISA. A “Positive” or “Negative” result was determined with an algorithm that included the methylation and mutation results and a logistic regression score, which combines DNA marker results with Hb and actin results. Algorithm results exceeding a threshold were called “Positive”. The algorithm provided good discriminative ability, stability, sensitivity and specificity. Robustness was tested with computer simulations and statistical techniques (leave-one-out and 10-fold cross validation). Results: At a 90% nominal specificity, sDNA-MT sensitivity was 98% for CRC (91/93) [Stage: I, 95% (20/21), II, 100% (23/23), III 96% (26/27), IV 100% (7/7) and I-III combined 97% (69/71)], 57% (65/114) for precursors ≥1 cm (AA, SSA), and 86% (12/14) for precursors with high grade dysplasia. CRC patients were typically referred to colonoscopy for symptoms and test sensitivity may be elevated relative to that seen with screening. Conclusion: With this study using a novel automated sDNA-MT analytic platform with logistic algorithm, we corroborate our earlier findings using a manual process and demonstrate a platform that allows testing to be performed routinely by molecular diagnostic capable laboratories. The high sensitivity of sDNA-MT for CRC across all stages and for advanced precursors with high-grade dysplasia could lead to improved non-invasive CRC screening performance with wide accessibility to patients. A large multi-site pivotal CRC screening study (DeeP-C study clinicaltrials.gov, NCT01397747) to support such use is underway. Citation Format: Graham P. Lidgard, Michael J. Domanico, Janelle J. Bruinsma, James Light, Zubin D. Gagrat, Rebecca L. Oldham-Haltom, Keith D. Fourrier, Hatim Allawi, Tracy C. Yab, Julie A. Simonson, Mary Devens, Russell I. Heigh, David A. Ahlquist, Barry M. Berger. An optimized molecular stool test for colorectal cancer screening: Evaluation of an automated analytic platform and logistic algorithm. [abstract]. In: Proceedings of the Eleventh Annual AACR International Conference on Frontiers in Cancer Prevention Research; 2012 Oct 16-19; Anaheim, CA. Philadelphia (PA): AACR; Cancer Prev Res 2012;5(11 Suppl):Abstract nr B12.