The clinical use of stress echocardiography in non-ischaemic heart disease: recommendations from the European Association of Cardiovascular Imaging and the American Society of Echocardiography
Abstract A unique and highly versatile technique, stress echocardiography (SE) is increasingly recognized for its utility in the evaluation of non-ischaemic heart disease. SE allows for simultaneous assessment of myocardial function and haemodynamics under physiological or pharmacological conditions. Due to its diagnostic and prognostic value, SE has become widely implemented to assess various conditions other than ischaemic heart disease. It has thus become essential to establish guidance for its applications and performance in the area of non-ischaemic heart disease. This paper summarizes these recommendations.
One-Year Clinical Outcomes With SAPIEN 3 Transcatheter Aortic Valve Replacement in High-Risk and Inoperable Patients With Severe Aortic Stenosis
Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.
The pathology and pathobiology of bicuspid aortic valve: State of the art and novel research perspectives
AbstractBicuspid aortic valve is the most prevalent cardiac valvular malformation. It is associated with a high rate of long‐term morbidity including development of calcific aortic valve disease, aortic regurgitation and concomitant thoracic aortic aneurysm and dissection. Recently, basic and translational studies have identified some key processes involved in the development of bicuspid aortic valve and its morbidity. The development of aortic valve disease and thoracic aortic aneurysm and dissection is the result of complex interactions between genotypes, environmental risk factors and specific haemodynamic conditions created by bicuspid aortic valve anatomy. Herein, we review the pathobiology of bicuspid aortic valve with a special emphasis on translational aspects of these basic findings. Important but unresolved problems in the pathology of bicuspid aortic valve and thoracic aortic aneurysm and dissection are discussed, along with the molecular processes involved.
Haemodynamic and anatomic progression of aortic stenosis
Background Aortic valve stenosis (AS) is a progressive disease, but the impact of baseline AS haemodynamic or anatomic severity on AS progression remains unclear. Methods In 149 patients (104 mild AS, 36 moderate AS and 9 severe AS) enrolled in 2 ongoing prospective cohorts (COFRASA/GENERAC), we evaluated AS haemodynamic severity at baseline and yearly, thereafter, using echocardiography (mean pressure gradient (MPG)) and AS anatomic severity using CT (degree of aortic valve calcification (AVC)). Results After a mean follow-up of 2.9±1.0 years, mean MGP increased from 22±11 to 30±16 mm Hg (+3±3 mm Hg/year), and mean AVC from 1108±891 to 1640±1251 AU (arbitrary units) (+188±176 AU/year). Progression of AS was strongly related to baseline haemodynamic severity (+2±3 mm Hg/year in mild AS, +4±3 mm Hg/year in moderate AS and +5±5 mm Hg/year in severe AS (p=0.01)), and baseline haemodynamic severity was an independent predictor of haemodynamic progression (p=0.0003). Annualised haemodynamic and anatomic progression rates were significantly correlated (r=0.55, p<0.0001), but AVC progression rate was also significantly associated with baseline haemodynamic severity (+141±133 AU/year in mild AS, +279±189 AU/year in moderate AS and +361±293 AU/year in severe AS, p<0.0001), and both baseline MPG and baseline AVC were independent determinants of AVC progression (p<0.0001). Conclusions AS progressed faster with increasing haemodynamic or anatomic severity. Our results suggest that a medical strategy aimed at preventing AVC progression may be useful in all subsets of patients with AS including those with severe AS and support the recommended closer follow-up of patients with AS as AS severity increases. Clinical trial registration COFRASA (clinicalTrial.gov number NCT 00338676) and GENERAC (clinicalTrial.gov number NCT00647088 ).
Impact of Aortic Annulus Size on Valve Hemodynamics and Clinical Outcomes After Transcatheter and Surgical Aortic Valve Replacement
Background— The objective was to evaluate the effects of aortic annulus size on valve hemodynamics and clinical outcomes in those patients included in the Placement of Aortic Transcatheter Valves (PARTNER) randomized controlled trial cohort A and the nonrandomized continued access cohort. Methods and Results— Patients included the randomized controlled trial (n=574) and nonrandomized continued access (n=1358) cohorts were divided in tertiles according to aortic annulus diameter (small aortic annulus tertile, medium aortic annulus tertile, and large aortic annulus tertile [LAA], respectively) as measured by transthoracic echocardiography. Severe prosthesis–patient mismatch was defined as an effective aortic orifice area of <0.65 cm 2 /m 2 . In the randomized controlled trial cohort, patients in the small aortic annulus tertile who underwent transcatheter aortic valve replacement had a lower incidence of severe prosthesis–patient mismatch (19.7% versus 37.5%; P =0.03) and only a trend toward a higher incidence of moderate-to-severe paravalvular leaks compared with surgical aortic valve replacement (5.7% versus 0%; P =0.06). In the LAA tertile, there were no differences in the rate of prosthesis–patient mismatch between groups, and a significant increase in moderate-to-severe paravalvular leaks was associated with transcatheter aortic valve replacement (9% versus 0%; P =0.01). There were no differences in mortality between transcatheter aortic valve replacement and surgical aortic valve replacement. In the nonrandomized continued access cohort, there were no differences in prosthesis–patient mismatch between the small aortic annulus and LAA tertiles, but a higher rate of moderate-to-severe paravalvular leaks was observed in the LAA tertile (5.9% versus 11.5%; P =0.009). Patients in the LAA tertile had a higher mortality rate at 1-year follow-up ( P =0.02), and differences persisted in multivariable analysis ( P =0.048 for LAA versus medium aortic annulus tertile, P =0.035 for LAA versus small aortic annulus tertile). Conclusions— Aortic annulus size had a major impact on valve hemodynamics and clinical outcomes after transcatheter aortic valve replacement and surgical aortic valve replacement. This study highlights the importance of considering aortic annulus size in the evaluation of high-risk patients who are candidates for aortic valve replacement. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.
The Role of Jet Eccentricity in Generating Disproportionately Elevated Transaortic Pressure Gradients in Patients with Aortic Stenosis
In patients with aortic stenosis (AS) and eccentric transaortic flow, greater pressure loss occurs as the jet collides with the aortic wall together with delayed and diminished pressure recovery. This leads to the elevated transaortic valve pressure gradients noted on both Doppler and cardiac catheterization. Such situations may present a diagnostic dilemma where traditional measures of stenosis severity indicate severe AS, while imaging modalities of the aortic valve geometric aortic valve area (GOA) suggest less than severe stenosis. In this study, we present a series of cases exemplifying this clinical dilemma and demonstrate how color M‐mode, 2D and 3D transthoracic (TTE) and transesophageal (TEE) echocardiography, cardiac computed tomography angiography (CTA), and magnetic resonance imaging (MRI), may be used to resolve such discrepancies.