121. Cardiac Implantable Electronic Device-Related Infective Endocarditis (CIED-IE): Clinical Features and Outcomes of Patients with Definite IE Who Fulfill Both Major Duke Criteria
Abstract Background Cardiac implantable electronic device-related infective endocarditis (CIED-IE) comprises 10–57% of total CIED infections. Patients with definite CIED-IE who fulfill both major modified Duke criteria have not been well characterized. Methods Data from the Multicenter Electrophysiologic Device Infection Cohort, a prospective, multinational study of CIED infections were used to describe a subset of patients with CIED-IE who met both major Duke criteria for definite IE (bloodstream infection and intracardiac vegetations [VEG]). Results Of 433 patients with CIED infection, 144 (33.3%) had definite CIED-IE. The median age was 68 years and 77.1% were male. Twelve (8.3%) had past CIED infection. Seventy-seven patients (53.5%) had permanent pacemakers, 38 (26.4%) had implantable cardioverter defibrillators, and 29 (20.1%) had combination devices. The median time following the last device procedure was 550 days. CIED-IE was early in 60 patients (41.7%) and late in 84 (58.3%). Most patients presented with fever (77.8%) and sepsis (44.4%) with a median symptom duration of 7 days. On echocardiography, lead VEG was noted in 125 patients (86.8%) and valvular VEG in 54 patients (37.5%) with the tricuspid valve involved in 56.5%. On the basis of VEG location, there were 90 patients (62.5%) with isolated lead-associated IE (LAE), 19 patients (13.2%) with isolated valve-associated IE (VAE), and 35 patients (24.3%) with both (LVAE). All patients had positive blood cultures and 63/119 (52.9%) had positive lead cultures. The predominant organism in blood was Staphylococcus aureus (42.4%), followed by coagulase-negative staphylococci (20.1%). CIED removal occurred in 131 patients (91%). There were 25 deaths during the index hospitalization and 34 total deaths (24.3%) by 6 months. Mortality correlated with age >75 (P = 0.023) and sepsis on presentation (P = 0.052). Infecting organism, site of VEG, and device removal did not impact the risk of death. Conclusion Definite CIED-IE is relatively common. The majority of patients tend to have late-onset infection and often present with sepsis. S. aureus is the dominant organism causing definite CIED-IE. Isolated LAE occurs in 63% of patients. Older age and sepsis on admission are associated with higher mortality. Disclosures All authors: No reported disclosures.
Spinal Cord Stimulator Infection: Approach to Diagnosis, Management, and Prevention
AbstractSpinal cord stimulation (SCS) is the most utilized invasive electrical neuromodulation treatment for the management of refractory chronic pain syndromes. Infection is one of the most dreaded complications related to SCS implantation and may prevent patients from receiving adequate pain treatment, adding to the initial cost and disability. Most SCS infections present as generator pocket infection. However, delay in diagnosis may lead to complications such as meningitis, epidural abscess, and/or vertebral osteomyelitis. Early recognition of SCS-related infections and associated complications is based on clinical suspicion, laboratory testing, and appropriate diagnostic imaging. While superficial surgical site infection following SCS implant may be treated with antibiotic therapy alone, deep infection involving implant warrants device removal to achieve cure. Duration of antimicrobial therapy depends on severity of clinical presentation and presence or absence of associated complications. Several preventive strategies can be incorporated in surgical practice to reduce the risk of SCS infection.
Microbiology of Implant-Based Breast Reconstruction Infections
Background Postsurgical complications have been an increasing concern for hospitals, particularly in light of payment reform. The costs to the health care system are increasing in light of Medicare penalties for readmissions for certain conditions. Surgical site infection following implant-based breast reconstruction (IBR) remains challenging. The rates of positive cultures and isolated microorganisms in IBR are unknown. This systematic review summarizes the reported microorganisms and positive culture rates in the existing literature. Methods A systematic review was performed using the guidelines outlined in Preferred Reporting Items for Systematic Reviews and Meta-analyses. Articles were included if breast implant infection rates and culture results were reported. Further subgroup analysis of culture positive infections was performed. Results A total of 25 studies were included, encompassing 25,177 IBR. Implant infections were reported in 1356 reconstructions (5.4%). Cultures were positive in 74.5% of infections. Gram-positive bacteria were the most common (68.6%), of which Staphylococcus species (51%) was the most isolated pathogen, followed by Pseudomonas. A subgroup analysis showed that early infections (63% vs 88%), radiotherapy (82% vs 93%), and acellular dermal matrix use (90% vs 100%) were associated with lower positive culture rates than their respective counterparts. Patients who received chemotherapy had higher positive culture results (94% vs 83%). Isolated microorganisms also varied among the subgroups. Conclusions This systematic review outlines reported microorganisms in IBR. Staphylococcus species and Pseudomonas were the most frequently reported microorganism. Negative cultures were reported in up to 25.5% of infections. Patients with early infections, radiotherapy, and acellular dermal matrix demonstrated higher negative culture rates. This review can help guide the use of empirical antimicrobial therapy in IBR.
Infective endocarditis due to Granulicatella elegans presenting with musculoskeletal symptoms
A 62-year-old man with essential hypertension and right L4-L5 hemilaminectomy was referred to rheumatology for evaluation of severe arthralgia and myalgia for 12 months. Review of symptoms was significant for night sweats and 20 pounds unintentional weight loss. Physical examination was significant for holosystolic murmur best heard at the cardiac apex of unclear chronicity. Laboratory investigations revealed elevated inflammatory markers, white blood cell count and B-type natriuretic peptide. Transoesophageal echocardiogram showed flail posterior mitral leaflet with severe mitral regurgitation and two vegetations (2.5×1 cm and 1.6×0.3 cm). Abdominal CT showed new focal splenic infarcts, and a brain MRI revealed subacute infarcts, consistent with the embolic phenomenon. Blood cultures grew Granulicatella elegans. The patient underwent mitral valve replacement surgery followed by 6 weeks of parenteral therapy with vancomycin and gentamicin, with full recovery at a 3-month follow-up.
Cardiovascular implantable electronic device infections due to enterococcal species: Clinical features, management, and outcomes
AbstractBackgroundEnterococcal cardiovascular implantable electronic device (CIED) infections are not well characterized.MethodsData from the Multicenter Electrophysiologic Device Infection Cohort, a prospective study of CIED infections, were used for descriptive analysis of adults with enterococcal CIED infections.ResultsOf 433 patients, 21 (4.8%) had enterococcal CIED infection. Median age was 71 years. Twelve patients (57%) had permanent pacemakers, five (24%) implantable cardioverter defibrillators, and four (19%) biventricular devices. Median time from last procedure to infection was 570 days. CIED‐related bloodstream infections occurred in three patients (14%) and 18 (86%) had infective endocarditis (IE), 14 (78%) of which were definite by the modified Duke criteria. IE cases were classified as follows: valvular IE, four; lead IE, eight; both valve and lead IE, six. Vegetations were demonstrated by transesophageal echocardiography in 17 patients (81%). Blood cultures were positive in 19/19 patients with confirmed results. The most common antimicrobial regimen was penicillin plus an aminoglycoside (33%). Antibiotics were given for a median of 43 days. Only 14 patients (67%) underwent device removal. There was one death during the index hospitalization with four additional deaths within 6 months (overall mortality 24%). There were no relapses.ConclusionsEnterococci caused 4.8% of CIED infections in our cohort. Based on the late onset after device placement or manipulation, most infections were likely hematogenous in origin. IE was the most common infection syndrome. Only 67% of patients underwent device removal. At 6 months follow‐up, no CIED infection relapses had occurred, but overall mortality was 24%.
Attachment is the source of all suffering: delineating mechanisms of adhesion in Staphylococcus aureus endocarditis
AbstractHistoplasma capsulatum is an endemic fungus that most oftenly causes a self‐limiting illness but can result in severe infections in immunocompromised patients including pulmonary or extra‐pulmonary disease. Rarely it can also cause a chronic progressive infection of the larynx. Herein, we report a case of laryngeal histoplasmosis in a kidney transplant patient who presented with progressive symptoms of several weeks of hoarseness, dysphagia and odynophagia. Laryngoscopic examination revealed thick plaques in the oropharynx with surrounding hyper‐erythema and histopathology showed numerous intracellular yeasts forms consistent with H capsulatum. Patient was initiated on treatment with itraconazole. Infection of the larynx due to H capsulatum is highly uncommon and therefore can result in an inappropriate or delayed diagnosis. A review of literature showed four previously reported cases of laryngeal histoplasmosis in patients with solid organ transplant. This is the first case series of laryngeal histoplasmosis in transplant recipients.
Disseminated Cryptococcus neoformans infection in a left ventricular assist device recipient
A 51-year-old man with a medical history of coronary artery disease and dyslipidaemia presented with acute myocardial infarction resulting in cardiogenic shock, necessitating intra-aortic balloon pump placement and extracorporeal membrane oxygenation (ECMO). His hospital course was complicated by several infectious complications including ECMO circuit Pseudomonas aeruginosa bloodstream infection and presumed infected right atrial thrombus. He subsequently underwent urgent left ventricular assist device placement and had a prolonged hospital stay. On day 100 of admission, he developed acute hypoxic respiratory distress with new pulmonary infiltrates. Sputum cultures grew Cryptococcus neoformans. Blood culture also grew C. neoformans after 96 hours of incubation and cryptococcal serum antigen was elevated at 1:20. Cerebrospinal fluid studies from a lumbar puncture were normal. He was treated with 2 weeks of combination antifungal therapy followed by life-long fluconazole suppression.
Molecular Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection
Abstract Background Sonicate fluid (SF), a solution derived from vortexing and sonication of explanted cardiovascular implantable electronic devices (CIEDs), is a higher-yield specimen compared with swabs or tissues for culture-based detection of microorganisms associated with CIED infection. Despite this, SF culture fails to identify a causative organism in ~50% of cases. We aimed to evaluate the diagnostic performance of 16S ribosomal RNA gene (rRNA) polymerase chain reaction (PCR)/sequencing of SF and compare it with that of SF culture. Methods We identified 322 SF specimens from extracted CIEDs and reviewed clinical data for each patient. Subjects were classified as having or not having CIED infection. Cases were subcategorized as culture negative if no significant growth was reported from SF cultures and as culture positive if an organism was detected above predefined thresholds. 16S rRNA PCR/sequencing was performed, with the organisms identified reported according to Clinical and Laboratory Standards Institute guidelines for sequence data interpretation. Results A total of 278 SF samples corresponded to infected cases, of which 160 were culture positive and 118 culture negative. The remaining 44 were from noninfected cases, of which 2 were culture positive. Compared with SF culture, the sensitivity of 16S rRNA PCR/sequencing was higher (64% vs 57.5%, P = .003). 16S rRNA PCR/sequencing detected a potential pathogen in 28 of 118 culture-negative cases, identifying staphylococci in the majority (18/28). Conclusions 16S rRNA PCR/sequencing has higher sensitivity to detect bacteria in SF from extracted CIEDs than does SF culture.
Predictors of Bloodstream Infection in Patients Presenting With Cardiovascular Implantable Electronic Device Pocket Infection