Back to Authors

Cook, Curtiss B.

https://orcid.org/0000-0001-5885-9959

Mayo Clinic

Mayo Clinic in Arizona

Citations 102

Self-Management Behaviors in Adults on Insulin Pump Therapy
Groat, Danielle , Grando, Adela , Soni, Hiral , Thompson, Bithika , Boyle, Mary , Bailey, Marilyn, Grando, Maria Adela, Cook, Curtiss B. , Grando, Maria Adela

Journal of Diabetes Science and Technology | September 1, 2016 | Volume: 11 | Issue: 2 | Pages: 233-239

10.1177/1932296816666538 Get It

Background: Successful diabetes management requires behavioral changes. Little is known about self-management behaviors (SMB) in adults on insulin pump (IP) therapy. Objective: Analyze and characterize observed common diabetes SMB in adult participants with type 1 diabetes (T1D) using IPs and to correlate behaviors with glycemic outcomes based on participant’s individual glucose targets. Materials and Methods: One month of IP data from adults with T1D were downloaded. Computer programs were written to automatically quantify the observed frequency of expected behaviors such as: insulin bolusing, checking blood glucose (BG), and recording carbohydrate intake, and other interactions with the IP. Results: Nineteen participants were recruited and 4,249 IP interactions were analyzed to ascertain behaviors. Intersubject variability of adherence to minimally expected behaviors was observed: daily documentation of carbohydrates and BG checks in 76.6 (31.7)% and 60.0 (32.5)%, respectively, and bolusing without consulting the IPBC in 13.0 (16.9)% of delivered boluses, while daily insulin bolus delivery was consistent 96.8 (5.7)%. Higher frequency of adherence to daily behaviors correlated with a higher number of glucose readings at target. Conclusion: Results indicate variability in SMB and do not always match recommendations. Case-scenarios based on observed real-life SMB could be incorporated into interviews/surveys to elucidate ways to improve SMB.
Risk of Hospitalization in Patients With Diabetes Mellitus Who have Solid-Organ Malignancy
Karlin, Nina J. , Castro, Janna C. , Kosiorek, Heidi , Cook, Curtiss B.

Future Science OA | July 15, 2016 | Volume: 2 | Issue: 3 | Pages: No page available

10.4155/fsoa-2016-0020 Get It

Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose
Belle, Jeffrey T. La , Adams, Anngela C. , Lin, Chi-En, Engelschall, Erica, Pratt, Breanna, Cook, Curtiss B.

Chemical Communications | June 17, 2016 | Volume: 52 | Issue: 59 | Pages: 9197-9204

10.1039/c6cc03609k Get It

Tear glucose sensing for diabetes management has long been sought as an alternative to more invasive self-monitoring of blood glucose (SMBG).
Perioperative Management of Patients with Diabetes Undergoing Ambulatory Elective Surgery
Coan, Kathryn E., Schlinkert, Andrew B., Beck, Brandon R., Haakinson, Danielle J. , Castro, Janna C. , Schlinkert, Richard T., Cook, Curtiss B.

Journal of Diabetes Science and Technology | June 7, 2016 | Volume: 7 | Issue: 4 | Pages: 983-989

10.1177/193229681300700421 Get It

Objective: The objective was to assess processes of care for patients with diabetes undergoing elective surgery. Methods: A retrospective review of medical records was conducted to determine frequency of perioperative glucose monitoring, changes in glucose control, and treatment of intraoperative hyperglycemia. Results: A total of 268 patients underwent 287 elective procedures. Mean age was 67 years, 63% were men, 97% had type 2 diabetes, and most (57%) were treated with oral hypoglycemic agents. Average perioperative time was approximately 8 h. Mean preoperative hemoglobin A1c was 7.0%; however, this value was checked in only 52% of cases. A glucose measurement was obtained in 89% of cases in the preoperative area and in 87% in the postanesthesia care unit, but in only 33% of cases did a value get checked intraoperatively. Average glucose was 139 mg/dl preoperatively, increasing to 166 mg/dl postoperatively ( p <.001). Glucose levels increased regardless of type of outpatient medical therapy used to treat hyperglycemia, except for those on combination oral agents plus insulin ( p =.06). Conclusions: These data indicate suboptimal documentation of outpatient hemoglobin A1c. Intraoperative glucose monitoring seldom occurred, despite prolonged periods under anesthesia and perioperative deterioration of glycemic control. Standards need to be developed and interventions are needed to enhance management of diabetes patients undergoing elective procedures.
Clinical Inertia during Postoperative Management of Diabetes Mellitus: Relationship between Hyperglycemia and Insulin Therapy Intensification
Coan, Kathryn E., Schlinkert, Andrew B., Beck, Brandon R., Haakinson, Danielle J. , Castro, Janna C. , Apsey, Heidi A., Schlinkert, Richard T., Cook, Curtiss B.

Journal of Diabetes Science and Technology | June 7, 2016 | Volume: 7 | Issue: 4 | Pages: 880-887

10.1177/193229681300700410 Get It

Objective: Our objective was to assess the application of insulin regimens in surgical postoperative patients with diabetes. Methods: A chart review was conducted of patients with diabetes who were hospitalized postoperatively between January 1 and April 30, 2011. Analysis was restricted to patients hospitalized for ≥3 days and excluded cases with an endocrinology consult. Insulin regimens were categorized as “basal plus short acting,” “short acting only,” or “none,” and the pattern of use was evaluated by hyperglycemia severity according to tertiles of both mean glucose and the number of glucose measurements >180 mg/dl. Results: Among cases selected for analysis ( n = 119), examination of changes in insulin use based on tertiles of mean glucose showed that use of basal plus short-acting insulin increased from 10% in the lowest tertile (mean glucose, 120 mg/dl) to 18% in the highest tertile (mean glucose, 198 mg/dl; p < .01); however, 70% of patients in the highest tertile continued to receive short-acting insulin only, with 12% receiving no insulin. Intensification of insulin to a basal plus short-acting regimen was also seen when changes were evaluated by the number of measurements >180 mg/dl ( p < .01), but 70% and 12% of patients in the highest tertile still remained only on short-acting insulin or received no insulin, respectively. Conclusions: Use of basal plus short-acting insulin therapy increased with worsening hyperglycemia, but many cases did not have therapy intensified to the recommended insulin regimen—evidence of clinical inertia. Strategies should be devised to overcome inpatient clinical inertia in the treatment of postoperative patients with diabetes.
Description and Preliminary Evaluation of a Diabetes Technology Simulation Course
Wilson, Rebecca , Bailey, Marilyn, Boyle, Mary E., Seifert, Karen M., Cortez, Karla Y., Baker, Leslie J., Hovan, Michael J., Wilson, Rebecca D, Stepánek, Jan , Cook, Curtiss B.

Journal of Diabetes Science and Technology | June 6, 2016 | Volume: 7 | Issue: 6 | Pages: 1561-1566

10.1177/193229681300700616 Get It

Background: We aim to provide data on a diabetes technology simulation course (DTSC) that instructs internal medicine residents in the use of continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring system (CGMS) devices. Methods: The DTSC was implemented during calendar year 2012 and conducted in the institution's simulation center. It consisted of a set of prerequisites, a practicum, and completion of a web-based inpatient CSII-ordering simulation. DTSC participants included only those residents in the outpatient endocrinology rotation. Questionnaires were used to determine whether course objectives were met and to assess the satisfaction of residents with the course. Questionnaires were also administered before and after the endocrine rotation to gauge improvement in familiarity with CSII and CGMS technologies. Results: During the first year, 12 of 12 residents in the outpatient endocrinology rotation completed the DTSC. Residents reported that the course objectives were fully met. The mean satisfaction score with the course ranged from 4.0 to 4.9 (maximum, 5), with most variables rated above 4.5. Self-reported familiarity with the operation of CSII and CGMS devices increased significantly in the postrotation survey compared with that on the prerotation survey (both p < .01). Conclusions: In this pilot program, simulation-based education increased the perceived familiarity of residents with CSII and CGMS technologies. In light of these preliminary findings, the course will continue to be offered, with further data accrual. Future work will involve piloting the DTSC approach among other types of providers, such as residents in other specialties or inpatient nursing staff.
Relationship Between the Timing of Preoperative Medical Visits and Day-Of-Surgery Glucose in Poorly Controlled Diabetes
Patel, Salma , Thompson, Bithika , McLemore, Ryan, Temkit, M’hamed , Schlinkert, Richard T., Apsey, Heidi A., Patel, Salma I, Thompson, Bithika M, McLemore, Ryan Y, Cook, Curtiss B.

Future Science OA | June 2, 2016 | Volume: 2 | Issue: 2 | Pages: No page available

10.4155/fsoa-2016-0009 Get It

Hyperglycemia During the Immediate Period Following Liver Transplantation
Werner, K. Tuesday , Castro, Janna C. , Carey, Elizabeth J. , Chakkera, Harini A. , Mackey, Patricia A, Cook, Curtiss B. , Mackey, Patricia , Chakkera, Harini A , Werner, Kristina Tuesday

Future Science OA | January 27, 2016 | Volume: 2 | Issue: 1 | Pages: No page available

10.4155/fsoa-2015-0010 Get It

Update on a Quality Initiative to Standardize Perioperative Care for Continuous Subcutaneous Insulin Infusion Therapy
Thompson, Bithika , Boyle, Mary E., Apsey, Heidi A., Seifert, Karen M., Schlinkert, Richard T., Stearns, Joshua D., Mackey, Patricia A, Thompson, Bithika M, Cook, Curtiss B. , Mackey, Patricia

Journal of Diabetes Science and Technology | June 19, 2015 | Volume: 9 | Issue: 6 | Pages: 1299-1306

10.1177/1932296815592027 Get It

Objective: The objective of the analysis was to review the effectiveness of a care process model (CPM) developed to guide management of patients on insulin pump therapy undergoing elective surgical procedures. Methods: Electronic medical records were reviewed to assess the impact of the CPM on documentation of insulin pump status, glucose monitoring, and safety during the perioperative phase of care. Post-CPM care was compared with management provided before CPM implementation. Results: We reviewed 45 cases on insulin pump therapy in the pre-CPM cohort and 106 in the post-CPM cohort. Demographic characteristics, categories of surgery, and perioperative times were not significantly different between the 2 groups. Recommended hemoglobin A1c monitoring occurred in 73% of cases in the pre-CPM cohort but improved to 94% in the post-CPM group ( P < .01). There was a higher frequency of documentation of the insulin pump during the preoperative, intraoperative, and postanesthesia care unit segments of care in the post- vs pre-CPM periods (all P < .01). The number of cases with intraoperative glucose monitoring increased (57% pre-CPM vs 81% post-CPM; P < .01). Glycemic control was comparable between the 2 CPM periods. Hypoglycemia was rare, with only 3 episodes in the pre-CPM group and 4 in the post-CPM. No adverse events associated with perioperative insulin pump use were observed. Conclusions: This analysis adds to previous data on use of insulin pump therapy during the perioperative period. Some processes require additional attention, but data continue to indicate that a standardized approach to care can lead to a successful and safe transition of insulin pump therapy throughout the perioperative period.
Where to Go Now With V-Go?
Thompson, Bithika , Thompson, Bithika M, Cook, Curtiss B.

Journal of Diabetes Science and Technology | June 15, 2015 | Volume: 9 | Issue: 5 | Pages: 1117-1118

10.1177/1932296815590155 Get It

V-Go™ is a mechanical continuous insulin delivery device releasing a basal amount of rapid acting insulin that also allows the user the ability to deliver discrete meal time or correction doses. This analysis reviews available published literature on the technology, and discusses a recent article comparing the V-Go system with multiple daily insulin injection therapy. Finally, suggestions for future studies are provided.