Background: The objective of this study was to assess disposal patterns for “sharps” among a cohort of patients with diabetes mellitus (DM) receiving insulin therapy. Method: A convenience sample of inpatients and outpatients was surveyed about how they disposed of sharps, how often they reused lancets and needles, and what education they had received about proper disposal. Safe disposal was defined as discarding sharps into a formal sharps or sealable container; otherwise, disposal was categorized as unsafe. Results: Of 150 respondents, 56% were men and 75% were white. The mean (SD) age was 56 (15) years; duration of DM, 20 (13) years; and hemoglobin A 1c , 8.1% (2.0%). Half the respondents reused a lancet two or more times, and 21% reused an insulin needle two or more times. Thirty-eight percent of respondents discarded lancets unsafely, and 33% discarded insulin needles unsafely, typically by throwing these items into household trash. Most respondents (75%) discarded insulin pens, vials, cartridges, insulin pump supplies, and continuous glucose monitor sensors into household trash. Most (64%) indicated that they had not received education on safe sharps-disposal practices, and 84% had never visited their municipal website for information on medical waste disposal. Conclusion: Approximately one-third of patients unsafely disposed of sharps. Unsafe disposal could cause millions of sharps to appear in the municipal solid waste stream, thereby posing a substantial public health hazard. Point-of-care patient education is important, but a broader public health campaign may be required.
How is the Weather? Forecasting Inpatient Glycemic Control
Objective: The objective of the analysis was to review the effectiveness of a care process model (CPM) developed to guide management of patients on insulin pump therapy undergoing elective surgical procedures. Methods: Electronic medical records were reviewed to assess the impact of the CPM on documentation of insulin pump status, glucose monitoring, and safety during the perioperative phase of care. Post-CPM care was compared with management provided before CPM implementation. Results: We reviewed 45 cases on insulin pump therapy in the pre-CPM cohort and 106 in the post-CPM cohort. Demographic characteristics, categories of surgery, and perioperative times were not significantly different between the 2 groups. Recommended hemoglobin A1c monitoring occurred in 73% of cases in the pre-CPM cohort but improved to 94% in the post-CPM group ( P < .01). There was a higher frequency of documentation of the insulin pump during the preoperative, intraoperative, and postanesthesia care unit segments of care in the post- vs pre-CPM periods (all P < .01). The number of cases with intraoperative glucose monitoring increased (57% pre-CPM vs 81% post-CPM; P < .01). Glycemic control was comparable between the 2 CPM periods. Hypoglycemia was rare, with only 3 episodes in the pre-CPM group and 4 in the post-CPM. No adverse events associated with perioperative insulin pump use were observed. Conclusions: This analysis adds to previous data on use of insulin pump therapy during the perioperative period. Some processes require additional attention, but data continue to indicate that a standardized approach to care can lead to a successful and safe transition of insulin pump therapy throughout the perioperative period.
V-Go™ is a mechanical continuous insulin delivery device releasing a basal amount of rapid acting insulin that also allows the user the ability to deliver discrete meal time or correction doses. This analysis reviews available published literature on the technology, and discusses a recent article comparing the V-Go system with multiple daily insulin injection therapy. Finally, suggestions for future studies are provided.