The Development of a Novel Lightweight Transradial Prosthetic: A Proof-of-Concept Study
McBryan, Sarah , Belle, Jeffrey T. La , Malkoc, Aldin

Technology and Innovation | January 14, 2019 | Volume: 20 | Issue: 1-2 | Pages: 47-53

10.21300/20.1-2.2018.47 Get It

A Disposable Tear Glucose Biosensor—Part 5: Improvements in Reagents and Tear Sampling Component
Lin, Chi, Ito, Yuka , Deng, Anna, Johns, Jared, Matloff, Daniel S., Sode, Koji , Belle, Jeffrey T. La , Cook, Curtiss B. , La Belle, Jeffrey T, Sode, Koji

Journal of Diabetes Science and Technology | April 18, 2018 | Volume: 12 | Issue: 4 | Pages: 842-846

10.1177/1932296818769944 Get It

A tear glucose (TG) sensor with an integrated tear sampler can provide a noninvasive method for calibrating the continuous TG contact lens and monitoring glucose. Expanding from previous work, an improved TG sensor that implements dried reagents, genetically modified glucose dehydrogenase (GDH), and a tear sampler was developed and compared against the TG sensor prepared with commercial GDH. It was found that neither sensor was affected by the tear interferents: ascorbic acid, acetaminophen, and uric acid. The sensor prepared with commercial GDH generated higher current. This suggests that using enzymes with lower K m may be advantageous when operating in low glucose environments like tears. The improved TG sensor also demonstrated the potential of integrating Schirmer’s test strip as a tear sampler for self-monitoring of TG.
The Development of a Glucose Dehydrogenase 3D-Printed Glucose Sensor: A Proof-of-Concept Study
Adams, Anngela C. , Belle, Jeffrey T. La , La Belle, Jeffrey T, Malkoc, Aldin

Journal of Diabetes Science and Technology | June 21, 2017 | Volume: 12 | Issue: 1 | Pages: 176-182

10.1177/1932296817715272 Get It

This work represents a preliminary proof-of-concept design and verification of a 3D-printed glucose biosensor. The proof of concept presented is the first example of glucose dehydrogenase sensor fabricated by a 3D-printer while maintaining similar features to current lab-industry standards. The sensor was verified to detect physiological glucose concentrations between 0 and 400 mg/dL with a linear coefficient as high as .97. This study showed that it was possible to use 3D-printed technology to create a biosensor sensitive to glucose detection. As availability and functionality of 3D-printers expands, this technology has the potential to be an option for diabetes management. This preliminary study shows that the 3D-printed sensor platform holds promise for sensitive glucose detection.
Toward the Development of a Glucose Dehydrogenase-Based Saliva Glucose Sensor Without the Need for Sample Preparation
Lin, Chi, Pratt, Breanna, Honikel, Mackenzie M. , Jenish, Alaina, Ramesh, Bhavna, Alkhan, Amnah, Belle, Jeffrey T. La , La Belle, Jeffrey T, Ramesh, Bhavna

Journal of Diabetes Science and Technology | June 19, 2017 | Volume: 12 | Issue: 1 | Pages: 83-89

10.1177/1932296817712526 Get It

Background: Strict glycemic control is known to be a vital key in the management of diabetes mellitus (DM). However, traditional methods face limitations in their efficacy due to the pain and invasiveness of needle pricking which often discourages DM patients from performing the required number of tests per day. Saliva glucose (SG) sensing has long been considered a noninvasive alternative to blood glucose monitoring for diabetes management, however the sample preparation and sensor detection limit have been deemed as challenges to overcome. Herein, we describe a preliminary clinical validation of a disposable SG sensor without any requirement for sample preparation. Methods: The sensor utilizes glucose dehydrogenase flavine-adenine dinucleotide (GDH-FAD) in conjunction with disposable screen printed electrodes to measure glucose levels in saliva collected directly from 9 healthy subjects. Cyclic voltammetry and amperometric-time (Amp-it) assays were used to develop calibration curves and test subjects. Sensor calibration was performed using simulated saliva at 6.5 pH and 37ºC. Results: The lower limit of detection was determined to be 0.11 mg/dL. A lag time of 15 minutes with a positive correlation between SG and BG levels was found, which agrees with literature results. The detected SG ranges from 2.38 to 3.40 mg/dL over a BG range of 90 to 143 mg/dL. Conclusion: This is the first reported use of measuring SG with GDH-FAD without prior sample preparation. Upon optimization, the sensor has the potential to serve as a supplement to blood glucose monitoring.
Towards the Future Development of an Electrochemical Continuous Multimarker Biosensor for Enhanced Glycemic Management
Lin, Chi, Probst, David , Honikel, Mackenzie M. , Belle, Jeffrey T. La , La Belle, Jeffrey T, Malkoc, Aldin

Journal of Diabetes Science and Technology | May 11, 2017 | Volume: 11 | Issue: 5 | Pages: 1053-1054

10.1177/1932296817707543 Get It

Enhancing Glycemic Control via Detection of Insulin Using Electrochemical Impedance Spectroscopy
Probst, David , Lin, Chi, Khanwalker, Mukund, Beck, Connor, Belle, Jeffrey T. La , Cook, Curtiss B. , La Belle, Jeffrey T, Malkoc, Aldin

Journal of Diabetes Science and Technology | March 16, 2017 | Volume: 11 | Issue: 5 | Pages: 930-935

10.1177/1932296817699639 Get It

Background: Currently, glycemic management for individuals with diabetes mellitus involves monitoring glucose only, which is insufficient as glucose metabolism involves other biomarkers such as insulin. Monitoring additional biomarkers alongside glucose has been proposed to improve glycemic control. In this work, the development of a rapid and label-free insulin biosensor with high sensitivity and accuracy is presented. The insulin sensor prototype also serves as a prior study for a multimarker sensing platform technology that can further improve glycemic control in the future. Methods: Electrochemical impedance spectroscopy was used to identify an optimal frequency specific to insulin detection on a gold disk electrode with insulin antibody immobilized, which was accomplished by conjugating the primary amines of insulin antibody to the carboxylic bond of the self-assembling monolayer on the gold surface. After blocking with ethanolamine, the insulin physiological concentration gradient was tested. The imaginary impedance was correlated to insulin concentration and the results were compared with standard equivalent circuit analysis and correlation of charge transfer resistance to target concentration. Results: The optimal frequency of insulin is 810.5 Hz, which is characterized by having the highest sensitivity and sufficient specificity. The lower limit of detection was 2.26 ρ M which is comparable to a standard and better than traditional approaches. Conclusion: An insulin biosensor prototype capable of detecting insulin in physiological range without complex data normalization was developed. This prototype will be the ground works of a multimarker platform sensor technology for future all-in-one glycemic management sensors.
Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose
Belle, Jeffrey T. La , Adams, Anngela C. , Lin, Chi-En, Engelschall, Erica, Pratt, Breanna, Cook, Curtiss B.

Chemical Communications | June 17, 2016 | Volume: 52 | Issue: 59 | Pages: 9197-9204

10.1039/c6cc03609k Get It

Tear glucose sensing for diabetes management has long been sought as an alternative to more invasive self-monitoring of blood glucose (SMBG).
Detection of 1,5-Anhydroglucitol by Electrochemical Impedance Spectroscopy
Adamson, Teagan, Belle, Jeffrey T. La , Cook, Curtiss B.

Journal of Diabetes Science and Technology | February 22, 2014 | Volume: 8 | Issue: 2 | Pages: 350-355

10.1177/1932296814523874 Get It

Background: Multiple markers are used to assess glycemic control in patients with diabetes mellitus (DM). New technology that permits simultaneous detection of multiple biomarkers combined with those used at the point of care indicative of glycemic control, including glycemic variability determined from 1,5-anhydroglucitol measurement, could provide better management and further insight into the disease. Methods: This platform was based on previous research involving glucose detection and uses electrochemical impedance spectroscopy to detect a range of 1,5-anhydroglucitol concentrations at an optimal binding frequency. The enzyme pyranose oxidase was fixed to gold electrodes while a sine wave of sweeping frequencies was induced in purified solutions and in variable presence of whole blood. Results: The optimal binding frequency for the detection of 1,5-anhydroglucitol was found to be 3.71 kHz. The impedance response compared to the concentration of target present was found to have a logarithmic slope of 7.04 with an R-squared value of 0.96. This response includes 2 experimental sets, a single test of a low concentration range and a high concentration range with 5 replicates. The relative standard deviation of the high range varied from 28% to 27% from lowest to highest concentrations. Best detection in complex solutions was found in lower blood concentrations of 0.5% and 1%, but maintained relatively high accuracy in concentrations 5% and 10%. Conclusions: The sensor platform was successfully evaluated at a high dynamic range of 1,5-AG in purified solutions. In the presence of whole blood, lowest percentages yielded the best results indicating that filtering interferents may be necessary in final device architecture.
A Disposable Tear Glucose Biosensor—Part 4
Belle, Jeffrey T. La , Engelschall, Erica, Lan, Kenneth, Shah, Pankti, Saez, Neil , Maxwell, Stephanie, Adamson, Teagan, Abou-Eid, Michelle, McAferty, Kenyon, Patel, Dharmendra, Patel, Dharmendra R., Cook, Curtiss B.

Journal of Diabetes Science and Technology | February 11, 2014 | Volume: 8 | Issue: 1 | Pages: 109-116

10.1177/1932296813511741 Get It

Objective: A prototype tear glucose (TG) sensor was tested in New Zealand white rabbits to assess eye irritation, blood glucose (BG) and TG lag time, and correlation with BG. Methods: A total of 4 animals were used. Eye irritation was monitored by Lissamine green dye and analyzed using image analysis software. Lag time was correlated with an oral glucose load while recording TG and BG readings. Correlation between TG and BG were plotted against one another to form a correlation diagram, using a Yellow Springs Instrument (YSI) and self-monitoring of blood glucose as the reference measurements. Finally, TG levels were calculated using analytically derived expressions. Results: From repeated testing carried over the course of 12 months, little to no eye irritation was detected. TG fluctuations over time visually appeared to trace the same pattern as BG with an average lag times of 13 minutes. TG levels calculated from the device current measurements ranged from 4 to 20 mg/dL and correlated linearly with BG levels of 75-160 mg/dL (TG = 0.1723 BG = 7.9448 mg/dL; R 2 = .7544). Conclusion: The first steps were taken toward preliminary development of a sensor for self-monitoring of tear glucose (SMTG). No conjunctival irritation in any of the animals was noted. Lag time between TG and BG was found to be noticeable, but a quantitative modeling to correlate lag time in this study is unnecessary. Measured currents from the sensors and the calculated TG showed promising correlation to BG levels. Previous analytical bench marking showed BG and TG levels consistent with other literature.
A Disposable Tear Glucose Biosensor—Part 3: Assessment of Enzymatic Specificity
Lan, Kenneth, McAferty, Kenyon, Shah, Pankti, Lieberman, Erica, Patel, Dharmendra, Belle, Jeffrey T. La , Cook, Curtiss B.

Journal of Diabetes Science and Technology | January 10, 2014 | Volume: 5 | Issue: 5 | Pages: 1108-1115

10.1177/193229681100500511 Get It

Background: A concept for a tear glucose sensor based on amperometric measurement of enzymatic oxidation of glucose was previously presented, using glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD) as the enzyme. Glucose dehydrogenase flavin adenine dinucleotide is further characterized in this article and evaluated for suitability in glucose-sensing applications in purified tear-like saline, with specific attention to the effect of interfering substances only. These interferents are specifically saccharides that could interact with the enzymatic activity seen in the sensor's performance. Methods: Bench top amperometric glucose assays were performed using an assay solution of GDH-FAD and ferricyanide redox mediator with samples of glucose, mannose, lactose, maltose, galactose, fructose, sucrose, and xylose at varying concentrations to evaluate specificity, linear dynamic range, signal size, and signal-to-noise ratio. A comparison study was done by substituting an equivalent activity unit concentration of glucose oxidase (GOx) for GDH-FAD. Results: Glucose dehydrogenase flavin adenine dinucleotide was found to be more sensitive than GOx, producing larger oxidation currents than GOx on an identical glucose concentration gradient, and GDH-FAD exhibited larger slope response (-5.65 × 10 −7 versus −3.11 × 10 −7 A/mM), signal-to-noise ratio (18.04 versus 2.62), and linear dynamic range (0–30 versus 0–10 mM), and lower background signal (−7.12 versus −261.63 nA) than GOx under the same assay conditions. GDH-FAD responds equally to glucose and xylose but is otherwise specific for glucose. Conclusion: Glucose dehydrogenase flavin adenine dinucleotide compares favorably with GOx in many sensor-relevant attributes and may enable measurement of glucose concentrations both higher and lower than those measurable by GOx. GDH-FAD is a viable enzyme to use in the proposed amperometric tear glucose sensor system and perhaps also in detecting extreme hypoglycemia or hyperglycemia in blood.