Back to Authors

Groat, Danielle

https://orcid.org/0000-0002-1180-4448

Mayo Clinic

University of Utah

Citations 9

Data-Driven Diabetes Education Guided by a Personalized Report for Patients on Insulin Pump Therapy
Groat, Danielle , Corrette, Krystal, Vellore, Vaishak, Bayuk, Mike, Karway, George , Boyle, Mary , Thompson, Bithika , McCoy, Rozalina, Grando, Adela , Boyle, Mary, McCoy, Rozalina G. , Grimm, Kevin J.

ACI Open | February 6, 2020 | Volume: 04 | Issue: 01 | Pages: e9-e21

10.1055/s-0039-1701022 Get It

Abstract Objective It is difficult to assess self-management behaviors (SMBs) and incorporate them into a personalized self-care plan. We aimed to develop and apply SMB phenotyping algorithms from data collected by diabetes devices and a mobile health (mHealth) application to create patient-specific SMBs reports to guide individualized interventions. Follow-up interventions aimed to understand patient's reasoning behind discovered SMB choices. Methods This study deals with adults on continuous subcutaneous insulin infusion using a continuous glucose monitor (CGM) who self-tracked SMBs with an mHealth application for 1 month. Patient-generated data were quantified and an SMB report was designed and populated for each participant. A diabetes educator used the report to conduct personalized, data-driven educational interventions. Thematic analysis of the intervention was conducted. Results Twenty-two participants recorded 118 alcohol, 251 exercise, 2,661 meal events, and 1,900 photos. A patient-specific SMB report was created from this data and used to conduct the educational intervention. High variability of SMB was observed between patients. There was variability in the percentage of alcohol events accompanied by a blood glucose check, median 79% (38–100% range), and frequency of changing the bolus waveform, median 11 (7–95 range). Interventions confirmed variability of SMBs. Main emerging themes from thematic analysis were: challenges and barriers, motivators, current SMB techniques, and future plans to improve glycemic control. Conclusion The ability to quantify SMBs and understand patients' rationale may help improve diabetes self-care and related outcomes. This study describes our first steps in piloting a patient-specific diabetes educational intervention, as opposed to the current “one size fits all” approach.
Self-Management Behaviors of Patients with Type 1 Diabetes: Comparing Two Sources of Patient-Generated Data
Karway, George , Groat, Danielle , Thompson, Bithika , Cook, Curtiss, Grando, Adela , Grimm, Kevin J. , Cook, Curtiss B.

Applied Clinical Informatics | January 22, 2020 | Volume: 11 | Issue: 01 | Pages: 070-078

10.1055/s-0039-1701002 Get It

Abstract Objectives This article aims to evaluate adult type 1 diabetes mellitus (T1DM) self-management behaviors (SMBs) related to exercise and alcohol on a survey versus a smartphone app to compare self-reported and self-tracked SMBs, and examine inter- and intrapatient variability. Methods Adults with T1DM on insulin pump therapy were surveyed about their alcohol, meal, and exercise SMBs. For 4 weeks, participants self-tracked their alcohol, meal, and exercise events, and their SMBs corresponding with these events via an investigator-developed app. Descriptive statistics and generalized linear mixed-effect models were used to analyze the data Results Thirty-five participants self-tracked over 5,000 interactions using the app. Variability in how participants perceived the effects of exercise and alcohol on their blood glucose was observed. The congruity between SMBs self-reported on the survey and those self-tracked with the app was measured as mean (SD). The lowest congruity was for alcohol and exercise with 61.9% (22.7) and 66.4% (20.2), respectively. Congruity was higher for meals with 80.9% (21.0). There was significant daily intra- and interpatient variability in SMBs related to preprandial bolusing: recommended bolus, p < 0.05; own bolus choice, p < 0.01; and recommended basal adjustment, p < 0.01. Conclusion This study highlights the variability in intra- and interpatient SMBs obtained through the use of a survey and app. The outcomes of this study indicate that clinicians could use both one-time and every-day assessment tools to assess SMBs related to meals. For alcohol and exercise, further research is needed to understand the best assessment method for SMBs. Given this degree of patient variability, there is a need for an educational intervention that goes beyond the traditional “one-size-fits-all” approach of diabetes management to target individualized treatment barriers.
Patient Perception and Satisfaction With Insulin Pump System: Pilot User Experience Survey
Bayuk, Mike, Karway, George , Corrette, Krystal, Groat, Danielle , Thompson, Bithika , Grando, Maria Adela , Cook, Curtiss B. , Grando, Adela

Journal of Diabetes Science and Technology | May 6, 2019 | Volume: 13 | Issue: 6 | Pages: 1142-1148

10.1177/1932296819843146 Get It

Background: The goal of this study was to assess patient perspectives and satisfaction with the MiniMed 670G insulin pump. Those participants who used the pump as part of a hybrid closed loop were also asked to provide their views on the automatic feature (auto mode). Methods: Adults with type 1 diabetes mellitus using the Medtronic™ 670G pump were asked about their experience with the device using a semi-structured survey developed by the research team. Responses were quantified to identify emergent themes. Results: Seventeen participants used the pump as part of a hybrid closed loop system, while four participants used the pump in combination with a nonintegrated continuous glucose monitoring system. Overall, participants indicated a high level of satisfaction with the pump (14/21) mostly because of improvements in blood glucose (BG) control (15/21). Least liked features were physical design and structure (6/21), frequency of user input (5/21), alert frequency (4/21), and difficulty of use (3/21). Those using the hybrid closed loop were satisfied with the auto mode feature (11/17), mostly because of improvements in BG control (9/17). The least liked features of the auto mode technology were that blood glucose levels remained elevated (5/17) and the frequency of alerts (4/17). Conclusion: Participants indicated a high level of satisfaction with the pump and its auto mode featured mostly because of improvements in BG control. They also pointed out some key aspects of the device that are of potential clinical or commercial relevance. Additional research is needed to further evaluate users' perspectives on this new device.
Comparing Real-Time Self-Tracking and Device-Recorded Exercise Data in Subjects with Type 1 Diabetes
Groat, Danielle , Kwon, Hyo, Thompson, Bithika , Grando, Maria Adela, Cook, Curtiss B. , Grando, Adela

Applied Clinical Informatics | December 26, 2018 | Volume: 09 | Issue: 04 | Pages: 919-926

10.1055/s-0038-1676458 Get It

Background Insulin therapy, medical nutrition therapy, and physical activity are required for the treatment of type 1 diabetes (T1D). There is a lack of studies in real-life environments that characterize patient-reported data from logs, activity trackers, and medical devices (e.g., glucose sensors) in the context of exercise. Objective The objective of this study was to compare data from continuous glucose monitor (CGM), wristband heart rate monitor (WHRM), and self-tracking with a smartphone application (app), iDECIDE, with regards to exercise behaviors and rate of change in glucose levels. Methods Participants with T1D on insulin pump therapy tracked exercise for 1 month with the smartphone app while WHRM and CGM recorded data in real time. Exercise behaviors tracked with the app were compared against WHRM. The rate of change in glucose levels, as recorded by CGM, resulting from exercise was compared between exercise events documented with the app and recorded by the WHRM. Results Twelve participants generated 277 exercise events. Tracking with the app aligned well with WHRM with respect to frequency, 3.0 (2.1) and 2.5 (1.8) days per week, respectively (p = 0.60). Duration had very high agreement, the mean duration from the app was 65.6 (55.2) and 64.8 (54.9) minutes from WHRM (p = 0.45). Intensity had a low concordance between the data sources (Cohen's kappa = 0.2). The mean rate of change of glucose during exercise was –0.27 mg/(dL*min) and was not significantly different between data sources or intensity (p = 0.21). Conclusion We collated and analyzed data from three heterogeneous sources from free-living participants. Patients' perceived intensity of exercise can serve as a surrogate for exercise tracked by a WHRM when considering the glycemic impact of exercise on self-care regimens.
Design and Testing of a Smartphone Application for Real-Time Self-Tracking Diabetes Self-Management Behaviors
Groat, Danielle , Soni, Hiral , Thompson, Bithika , Cook, Curtiss B. , Grando, Adela , Kaufman, David Ross

Applied Clinical Informatics | June 20, 2018 | Volume: 09 | Issue: 02 | Pages: 440-449

10.1055/s-0038-1660438 Get It

Background Type 1 diabetes (T1D) care requires multiple daily self-management behaviors (SMBs). Preliminary studies on SMBs rely mainly on self-reported survey and interview data. There is little information on adult T1D SMBs, along with corresponding compensation techniques (CTs), gathered in real-time. Objective The article aims to use a patient-centered approach to design iDECIDE, a smartphone application that gathers daily diabetes SMBs and CTs related to meal and alcohol intake and exercise in real-time, and contrast patients' actual behaviors against those self-reported with the app. Methods Two usability studies were used to improve iDECIDE's functionality. These were followed by a 30-day pilot test of the redesigned app. A survey designed to capture diabetes SMBs and CTs was administered prior to the 30-day pilot test. Survey results were compared against iDECIDE logs. Results Usability studies revealed that participants desired advanced features for self-tracking meals and alcohol intake. Thirteen participants recorded over 1,200 CTs for carbohydrates during the 30-day study. Participants also recorded 76 alcohol and 166 exercise CTs. Comparisons of survey responses and iDECIDE logs showed mean% (standard deviation) concordance of 77% (25) for SMBs related to meals, where concordance of 100% indicates a perfect match. There was low concordance of 35% (35) and 46% (41) for alcohol and exercise events, respectively. Conclusion The high variability found in SMBs and CTs highlights the need for real-time diabetes self-tracking mechanisms to better understand SMBs and CTs. Future work will use the developed app to collect SMBs and CTs and identify patient-specific diabetes adherence barriers that could be addressed with individualized education interventions.
Self-Reported Compensation Techniques for Carbohydrate, Exercise, and Alcohol Behaviors in Patients With Type 1 Diabetes on Insulin Pump Therapy
Groat, Danielle , Soni, Hiral , Thompson, Bithika , Grando, Maria Adela, Cook, Curtiss B. , Grando, Adela

Journal of Diabetes Science and Technology | July 11, 2017 | Volume: 12 | Issue: 2 | Pages: 412-414

10.1177/1932296817718848 Get It

Studies have found variability in self-care behaviors in patients with type 1 diabetes, particularly when incorporating exercise and alcohol consumption. The objective of this study was to provide results from a survey to understand (1) insulin pump behaviors, (2) reported self-management behaviors for exercise and alcohol, and (3) perceptions of the effects of exercise and alcohol on blood glucose (BG) control. Fourteen participants from an outpatient endocrinology practice were recruited and administered an electronic survey. Compensation techniques for exercise and alcohol, along with reasons for employing the techniques were identified. Also identified were factors that participants said affected BG control with regard to exercise and alcohol. These results confirm the considerable inconsistency patients have about incorporating exercise and alcohol into decisions about self-management behaviors.
A Methodology to Compare Insulin Dosing Recommendations in Real-Life Settings
Groat, Danielle , Thompson, Bithika , Neto, Pedro Cunha Mendes , Soni, Hiral , Boyle, Mary E., Bailey, Marilyn, Grando, Maria A, Cook, Curtiss B. , Grando, Adela

Journal of Diabetes Science and Technology | April 13, 2017 | Volume: 11 | Issue: 6 | Pages: 1174-1182

10.1177/1932296817704444 Get It

Background: We propose a methodology to analyze complex real-life glucose data in insulin pump users. Methods: Patients with type 1 diabetes (T1D) on insulin pumps were recruited from an academic endocrinology practice. Glucose data, insulin bolus (IB) amounts, and self-reported alcohol consumption and exercise events were collected for 30 days. Rules were developed to retrospectively compare IB recommendations from the insulin pump bolus calculator (IPBC) against recommendations from a proposed decision aid (PDA) and for assessing the PDA’s recommendation for exercise and alcohol. Results: Data from 15 participants were analyzed. When considering instances where glucose was below target, the PDA recommended a smaller dose in 14%, but a larger dose in 13% and an equivalent IB in 73%. For glucose levels at target, the PDA suggested an equivalent IB in 58% compared to the subject’s IPBC, but higher doses in 20% and lower in 22%. In events where postprandial glucose was higher than target, the PDA suggested higher doses in 25%, lower doses in 13%, and equivalent doses in 62%. In 64% of all alcohol events the PDA would have provided appropriate advice. In 75% of exercise events, the PDA appropriately advised an IB, a carbohydrate snack, or neither. Conclusions: This study provides a methodology to systematically analyze real-life data generated by insulin pumps and allowed a preliminary analysis of the performance of the PDA for insulin dosing. Further testing of the methodological approach in a broader diabetes population and prospective testing of the PDA are needed.
Characterization of Exercise and Alcohol Self-Management Behaviors of Type 1 Diabetes Patients on Insulin Pump Therapy
Grando, Adela , Groat, Danielle , Soni, Hiral , Boyle, Mary , Bailey, Marilyn, Thompson, Bithika , Grando, Maria Adela, Cook, Curtiss B. , Grando, Maria Adela

Journal of Diabetes Science and Technology | September 5, 2016 | Volume: 11 | Issue: 2 | Pages: 240-246

10.1177/1932296816663746 Get It

Background: There is a lack of systematic ways to analyze how diabetes patients use their insulin pumps to self-manage blood glucose to compensate for alcohol ingestion and exercise. The objective was to analyze “real-life” insulin dosing decisions occurring in conjunction with alcohol intake and exercise among patients using insulin pumps. Methods: We recruited adult type 1 diabetes (T1D) patients on insulin pump therapy. Participants were asked to maintain their daily routines, including those related to exercising and consuming alcohol, and keep a 30-day journal on exercise performed and alcohol consumed. Thirty days of insulin pump data were downloaded. Participants’ actual insulin dosing behaviors were compared against their self-reported behaviors in the setting of exercise and alcohol. Results: Nineteen T1D patients were recruited and over 4000 interactions with the insulin pump were analyzed. The analysis exposed variability in how subjects perceived the effects of exercise/alcohol on their blood glucose, inconsistencies between self-reported and observed behaviors, and higher rates of blood glucose control behaviors for exercise versus alcohol. Conclusion: Compensation techniques and perceptions on how exercise and alcohol affect their blood glucose levels vary between patients. Improved individualized educational techniques that take into consideration a patient’s unique life style are needed to help patients effectively apply alcohol and exercise compensation techniques.
Self-Management Behaviors in Adults on Insulin Pump Therapy
Groat, Danielle , Grando, Adela , Soni, Hiral , Thompson, Bithika , Boyle, Mary , Bailey, Marilyn, Grando, Maria Adela, Cook, Curtiss B. , Grando, Maria Adela

Journal of Diabetes Science and Technology | September 1, 2016 | Volume: 11 | Issue: 2 | Pages: 233-239

10.1177/1932296816666538 Get It

Background: Successful diabetes management requires behavioral changes. Little is known about self-management behaviors (SMB) in adults on insulin pump (IP) therapy. Objective: Analyze and characterize observed common diabetes SMB in adult participants with type 1 diabetes (T1D) using IPs and to correlate behaviors with glycemic outcomes based on participant’s individual glucose targets. Materials and Methods: One month of IP data from adults with T1D were downloaded. Computer programs were written to automatically quantify the observed frequency of expected behaviors such as: insulin bolusing, checking blood glucose (BG), and recording carbohydrate intake, and other interactions with the IP. Results: Nineteen participants were recruited and 4,249 IP interactions were analyzed to ascertain behaviors. Intersubject variability of adherence to minimally expected behaviors was observed: daily documentation of carbohydrates and BG checks in 76.6 (31.7)% and 60.0 (32.5)%, respectively, and bolusing without consulting the IPBC in 13.0 (16.9)% of delivered boluses, while daily insulin bolus delivery was consistent 96.8 (5.7)%. Higher frequency of adherence to daily behaviors correlated with a higher number of glucose readings at target. Conclusion: Results indicate variability in SMB and do not always match recommendations. Case-scenarios based on observed real-life SMB could be incorporated into interviews/surveys to elucidate ways to improve SMB.