Background Insulin therapy, medical nutrition therapy, and physical activity are required for the treatment of type 1 diabetes (T1D). There is a lack of studies in real-life environments that characterize patient-reported data from logs, activity trackers, and medical devices (e.g., glucose sensors) in the context of exercise. Objective The objective of this study was to compare data from continuous glucose monitor (CGM), wristband heart rate monitor (WHRM), and self-tracking with a smartphone application (app), iDECIDE, with regards to exercise behaviors and rate of change in glucose levels. Methods Participants with T1D on insulin pump therapy tracked exercise for 1 month with the smartphone app while WHRM and CGM recorded data in real time. Exercise behaviors tracked with the app were compared against WHRM. The rate of change in glucose levels, as recorded by CGM, resulting from exercise was compared between exercise events documented with the app and recorded by the WHRM. Results Twelve participants generated 277 exercise events. Tracking with the app aligned well with WHRM with respect to frequency, 3.0 (2.1) and 2.5 (1.8) days per week, respectively (p = 0.60). Duration had very high agreement, the mean duration from the app was 65.6 (55.2) and 64.8 (54.9) minutes from WHRM (p = 0.45). Intensity had a low concordance between the data sources (Cohen's kappa = 0.2). The mean rate of change of glucose during exercise was –0.27 mg/(dL*min) and was not significantly different between data sources or intensity (p = 0.21). Conclusion We collated and analyzed data from three heterogeneous sources from free-living participants. Patients' perceived intensity of exercise can serve as a surrogate for exercise tracked by a WHRM when considering the glycemic impact of exercise on self-care regimens.
Insulin Pumping Patches: Emerging Insulin Delivery Systems
In this special section of JDST, patch-pump delivery systems (“patch pumps”) are discussed. Patch pumps are novel insulin delivery systems that have emerged on the market; offering flexible insulin delivery options. These systems offer several advantages over conventional insulin pump delivery systems and are gaining popularity. Patch pumps are free of tubing, small, and lightweight. In this special section, the authors discuss both the simple and complex patch pumps currently available on the US market as well as those that are currently under development. Current technologies used to operate these pumps are discussed in detail, and potential promising technologies are presented. Available data on patient preferences, clinical trial data, and the future of patch pumps are discussed.
Implications of melanoma with diabetes mellitus on patient outcomes.
Background Type 1 diabetes (T1D) care requires multiple daily self-management behaviors (SMBs). Preliminary studies on SMBs rely mainly on self-reported survey and interview data. There is little information on adult T1D SMBs, along with corresponding compensation techniques (CTs), gathered in real-time. Objective The article aims to use a patient-centered approach to design iDECIDE, a smartphone application that gathers daily diabetes SMBs and CTs related to meal and alcohol intake and exercise in real-time, and contrast patients' actual behaviors against those self-reported with the app. Methods Two usability studies were used to improve iDECIDE's functionality. These were followed by a 30-day pilot test of the redesigned app. A survey designed to capture diabetes SMBs and CTs was administered prior to the 30-day pilot test. Survey results were compared against iDECIDE logs. Results Usability studies revealed that participants desired advanced features for self-tracking meals and alcohol intake. Thirteen participants recorded over 1,200 CTs for carbohydrates during the 30-day study. Participants also recorded 76 alcohol and 166 exercise CTs. Comparisons of survey responses and iDECIDE logs showed mean% (standard deviation) concordance of 77% (25) for SMBs related to meals, where concordance of 100% indicates a perfect match. There was low concordance of 35% (35) and 46% (41) for alcohol and exercise events, respectively. Conclusion The high variability found in SMBs and CTs highlights the need for real-time diabetes self-tracking mechanisms to better understand SMBs and CTs. Future work will use the developed app to collect SMBs and CTs and identify patient-specific diabetes adherence barriers that could be addressed with individualized education interventions.
Consensus Statement on Use of Continuous Subcutaneous Insulin Infusion Therapy in the Hospital
In May 2017, the Diabetes Technology Society convened a panel of US experts on inpatient diabetes management to discuss the current and potential role of continuous subcutaneous insulin infusion (CSII) therapy in the hospital. The panel (1) discussed evidence for current use of CSII in the hospital, (2) recommended contraindications for use in the hospital, and (3) recommended guidelines to maximize chances for safe use of CSII in the hospital. Panel members agreed that larger, prospective, randomized studies are needed to evaluate safety and efficacy of CSII use in the hospital. As CSII technology becomes more complex and its use increases, it is imperative that institutional protocols be in place to ensure safe use of this technology and safe transitions across care areas. Providers need to be cognizant that not all patients currently using CSII as an outpatient are appropriate candidates for continued use in the hospital. This consensus statement provides guidelines for practitioners who may encounter patients using this technology in the inpatient setting.
A Disposable Tear Glucose Biosensor—Part 5: Improvements in Reagents and Tear Sampling Component
A tear glucose (TG) sensor with an integrated tear sampler can provide a noninvasive method for calibrating the continuous TG contact lens and monitoring glucose. Expanding from previous work, an improved TG sensor that implements dried reagents, genetically modified glucose dehydrogenase (GDH), and a tear sampler was developed and compared against the TG sensor prepared with commercial GDH. It was found that neither sensor was affected by the tear interferents: ascorbic acid, acetaminophen, and uric acid. The sensor prepared with commercial GDH generated higher current. This suggests that using enzymes with lower K m may be advantageous when operating in low glucose environments like tears. The improved TG sensor also demonstrated the potential of integrating Schirmer’s test strip as a tear sampler for self-monitoring of TG.
Survival and Glycemic Control Outcomes Among Patients with Coexisting Pancreatic Cancer and Diabetes Mellitus