Objective: With advancements in surgical equipment and procedures, human–system interactions in operating rooms affect surgeon workload and performance. Workload was measured across surgical specialties using surveys to identify potential predictors of high workload for future performance improvement. Summary Background Data: Surgical instrumentation and technique advancements have implications for surgeon workload and human–systems interactions. To understand and improve the interaction of components in the work system, NASA-Task Load Index can measure workload across various fields. Baseline workload measurements provide a broad overview of the field and identify areas most in need of improvement. Methods: Surgeons were administered a modified NASA-Task Load Index survey (0 = low, 20 = high) following each procedure. Patient and procedural factors were retrieved retrospectively. Results: Thirty-four surgeons (41% female) completed 662 surgery surveys (M = 14.85, SD = 7.94), of which 506 (76%) have associated patient and procedural data. Mental demand (M = 7.7, SD = 5.56), physical demand (M = 7.0, SD = 5.66), and effort (M = 7.8, SD = 5.77) were the highest rated workload subscales. Surgeons reported difficulty levels higher than expected for 22% of procedures, during which workload was significantly higher ( P < 0.05) and procedural durations were significantly longer ( P > 0.001). Surgeons reported poorer perceived performance during cases with unexpectedly high difficulty ( P < 0.001). Conclusions: When procedural difficulty is greater than expected, there are negative implications for mental and physical demand that result in poorer perceived performance. Investigations are underway to identify patient and surgical variables associated with unexpected difficulty and high workload. Future efforts will focus on re-engineering the surgical planning process and procedural environment to optimize workload and performance for improved surgical care.
Evidence-based intraoperative microbreak activities for reducing musculoskeletal injuries in the operating room
With advancements in surgical techniques, patients have experienced improvements in health and recovery outcomes. However, about 87% of laparoscopic surgeons [1] and an increasing number of surveyed allied health professionals [2, 3] report musculoskeletal symptoms. Medical practitioners and human factors engineers have highlighted the “hostile” and “dangerous” operating room (OR) environment [1, 4, 5]. With increasing technology and surgical case complexity, physical demands for surgical team members will continue to increase due to circumstances such as technology restricting posture, taking up working space and more team members working around smaller surgical incisions [6]. There is widespread concern that these medical professionals’ work is unsustainable for safe and healthy patients and surgical team members. Surgical team members can benefit from posture improvement during surgery; however, direct postural feedback may be difficult during their work due to the high visual and auditory stimuli during surgery. The tactile modality has been recently explored as a method to provide additional information without interfering with cognitive resources dedicated to visual and auditory pathways [7]. Tactile devices have successfully been implemented in high-stress environments, e.g., military, healthcare, and rehabilitation with a resulting improvement in performance [8–11]. Vibrotactile feedback has been specifically implemented in the healthcare field for improved performance by 31–75% anesthesiologists during simulated tasks [10]. Additionally, it has contributed to improved postural control in rehabilitation patients[11]. Despite success in other application areas, the potential of tactile devices for improving healthcare workers’ safety and performance remains unexplored. This study is a part of a larger project to design a wearable device that provides realtime vibrotactile feedback for preventing fatigue and musculoskeletal disorders for healthcare workers in the workplace. This specific aim of this study is to measure distraction, frustration, and performance during a surgical simulation task performed with and without vibrotactile feedback. This is a test of initial feasibility of vibrotactile feedback for use in training proper ergonomics for surgical team members. The researchers hypothesize that there will be some distraction with the vibrotactile feedback wearable but no frustration or performance degradation during the basic simulation task.
Human Factors Applications to Mitigate Design Limitations of a Wearable Telemedicine Heart Rate Monitor
The time required to get a device to market is critical to a successful design, development, and manufacturing process [1]. Achieving status of the first device to market is often a priority for manufacturers and developers. Upon market introduction, it is well known that device performance must meet at least minimum standards in order to provide consumer satisfaction and be a successful product to prevent competitive devices from taking over the market [1]. However, if a design only meets minimum expectations, it may struggle to maintain market control. This demonstrates the tradeoffs of speed-to-market and performance, for which optimization has not been clearly defined [2]. Product performance and usability can be designed in, evaluated and enhanced in order to avoid user errors and achieve optimal profitability. For medical devices, clinical trials are a key step in preparing to take a device to market. Clinical trials can allow for analyses of the effectiveness of the device in the patient care process. For wearable medical devices, patient usability is crucial to patient adherence and safety since the device will be operated by non-medically trained individuals [3,4]. Without adequate usability, adherence and continuity of care are greatly reduced which will reduce the overall effectiveness of the device [5,6]. Human factors principles can best be incorporated in the design process to improve the usability of medical devices and patient safety [5,6,7], specifically for those used in telemedicine [4] and cardiovascular treatment [3]. The objective of this project was to evaluate a telemedicine heart rate monitoring device for patient usability in order to improve the next device’s performance and lead to greater patient adherence for the current version via an improved user manual.
Iterative Implementation of a Remote Cardiac Patient Monitoring Device using Qualitative Analysis and Human Factors Engineering
Remote monitoring has the potential to improve patient care and satisfaction while reducing the cost of care and burden on the healthcare system for Congestive Heart Failure (CHF) and Atrial Fibrillation (AF) patients. However, the device must be convenient and easy for the population to use correctly. In this study, human factors and qualitative researchers evaluated the use of a remote cardiac monitoring device during a clinical trial with 74 CHF and AF patients. Human factors usability concerns centered on device use and the information presented in the manual. The key themes identified during the qualitative analysis were related to patient education. These findings were incorporated into device design, user manual, or education material updates. This study illustrates how these methods can infuse patient experience into device design to inform continued quality improvement and usability refinement specifically in devices to aid CHF and AF patients without added burden.
A Preliminary Comparison of Three Tourniquet Instructions for Just-in-Time Guidance of a Simulated Tourniquet Application
The American College of Surgeons (ACS) and the Department of Homeland Security (DHS) encourage the use of tourniquets as part of the “Stop the Bleed” campaign. Both have provided instructions for layperson tourniquet application in order to save the life of a hemorrhaging trauma victim. This study sought to compare the impact of using ACS and DHS instructions with manufacturer-provided instructions for the completion of simulated tourniquet application steps. Thirty surgical trainees completed a simulated tourniquet application with one of the three instruction sets. Their completion time and success for each step were measured. Participants that received ACS instructions failed the fewest number of steps (p < 0.01) and completed the task faster (Mean (SD) = 70 (33) seconds) compared to those with the manufacturer-provided instructions (p < 0.01). Tourniquet instruction sets need to be refined in order to optimize the success rate of just-in-time guidance for tourniquet application.
Do Trauma Activations Affect Interruptions in the Emergency Department?
Clinicians have anecdotally indicated that interruptions increase following trauma activations in the emergency department (ED), yet it is unknown whether interruptions change following the end of a trauma case. This study aimed to examine the interruption characteristics of clinicians that participate in trauma activations before and after activations using the SEIPS model. Observers shadowed ED clinicians across entire shifts and logged interruptions that affected clinicians in a tablet PC-based tool. Interruption characteristics captured included duration, nature, location, and task priority. Trauma activations lasting more than five minutes were also recorded. Only interruptions occurring within one-hour of trauma activations were included in the analysis. Chi-square analyses identified significant associations between SEIPS-categorized interruptions and the interruption priority, p < 0.01, and between the SEIPS-categorized interruptions and the interruption location, p = 0.01, pre- and post-trauma activations. Identifying these associations revealed key opportunities to reduce unnecessary interruptions in the ED.
The Stop The Bleed initiative was developed by the Department of Homeland Security to educate lay providers in bleeding reduction strategies. The current study evaluated: (1)three tourniquet instructions using a simulated tourniquet task and (2)participant confidence levels in tourniquet use and lay provider training. Thirty participants with limited clinical experience applied a tourniquet to a simulated limb using one of three instruction sets. Twelve of these participants (40%) participated in a tourniquet training session and focus group to discuss each instruction set. Participants preferred the most simple and pictoral instruction set, and identified opportunities for improvement in each set. Participant confidence in tourniquet use increased significantly following the task and the focus group. After the focus group, participant confidence in instructing lay providers on proper tourniquet use significantly increased. Adding key steps, contextual pictures, and indicators of success to instructions could support lay providers stop the bleed in life-threatening situations.
Validation of Inertial Measurement Units for Upper Body Kinematics
The purpose of this study was to validate a commercially available inertial measurement unit (IMU) system against a standard lab-based motion capture system for the measurement of shoulder elevation, elbow flexion, trunk flexion/extension, and neck flexion/extension kinematics. The validation analyses were applied to 6 surgical faculty members performing a standard, simulated surgical training task that mimics minimally invasive surgery. Three-dimensional joint kinematics were simultaneously recorded by an optical motion capture system and an IMU system with 6 sensors placed on the head, chest, and bilateral upper and lower arms. The sensor-to-segment axes alignment was accomplished manually. The IMU neck and trunk IMU flexion/extension angles were accurate to within 2.9 ± 0.9 degrees and 1.6 ± 1.1°, respectively. The IMU shoulder elevation measure was accurate to within 6.8 ± 2.7° and the elbow flexion measure was accurate to within 8.2 ± 2.8°. In the Bland-Altman analyses, there were no significant systematic errors present; however, there was a significant inversely proportional error across all joints. As the gold standard measurement increased, the IMU underestimated the magnitude of the joint angle. This study reports acceptable accuracy of a commercially available IMU system; however, results should be interpreted as protocol specific.
Preventing our Caregivers from Becoming Patients – Challenges, Successes, and Trends Faced by Hospital Risk Managers and Ergonomists
Healthcare workers suffer musculoskeletal disorders at rates that exceed most other industries. Despite this, many healthcare facilities do not follow best practices that are proven to reduce risk of injury. This discussion panel will explore the reasons for why the healthcare industry struggles to prevent injuries and will outline successful strategies for protecting workers. The panelists are leaders and advisors for large medical systems and their specialties include ergonomics, safe patient handling, and patient safety. The panelists relate the critical challenges faced when preventing caregiver injuries. Such challenges include underreporting of staff injuries, lack of funding or administrative support, and inability to sell the connections among caregiver safety, caregiver productivity, and patient safety. The panelists also share success stories of when they have achieved positive change and explain the strategies that were effective. Practitioners should gain new insights for implementing successful change, and researchers will be exposed to new and important research questions.