Abstract Objective The American College of Surgeons (ACS) encourages clinicians to provide training to laypeople on tourniquet application. It is unclear whether clinicians are confident in their abilities and equipped with adequate knowledge, skills, and resources. This study aimed to determine surgical trainee knowledge and attitudes regarding tourniquet application and compare the effectiveness of instructions. Methods Thirty surgical trainees performed a tourniquet application simulation using a Combat Application Tourniquet and one of the three instructions sets developed by ACS, Department of Homeland Security, and the tourniquet manufacturer. Participants reported tourniquet knowledge, attitudes, and confidence and discussed the instructions. One instruction set was updated and compared to the original set with 20 new trainees. Results Participants with ACS instructions passed the greatest number of steps (p < 0.01) and completed the task significantly faster compared to those with manufacturer instructions (p < 0.01). Participants (80%) reported favorable views toward tourniquets but 30–60% did not align with to ACS tourniquet guidelines. Focus group participants suggested revisions to the ACS instructions. Comparing the original and revised version of these instructions resulted in no significant improvements. Conclusions ACS instructions provide guidance; however, improvements to tourniquet instruction are needed for success in controlling exsanguinating hemorrhage.
Sweating the Little Things: Tourniquet Application Efficacy in Two Models of Pediatric Limb Circumference
AbstractBackgroundCurrent military recommendations include the use of tourniquets (TQ) in appropriate pediatric trauma patients. Although the utility of TQs has been well documented in adult patients, the efficacy of TQ application in pediatric patients is less clear. The current study attempted to identify physical constraints for TQ use in two simulated pediatric limb models.MethodsFive different TQ (Combat Application Tourniquet (CAT) Generation 6 and Generation 7, SOFTT (SOF Tactical Tourniquet), SOFTT-W (SOF Tactical Tourniquet – Wide), SWAT-T (Stretch Wrap and Tuck – Tourniquet) and a trauma dressing were evaluated in two simulated pediatric limb models. Model one employed four cardiopulmonary resuscitation (CPR) manikins simulating infant (Simulaids SaniBaby), 1 year (Gaumard HAL S3004), and 5 years (Laerdal Resusci Junior, Gaumard HAL S3005). Model two utilized polyvinyl chloride (PVC) piping with circumferences ranging from 4.25” to 16.5”. Specific end-points included tightness of the TQ and ability to secure the windlass (where applicable).ResultsIn both models, the ability to successfully apply and secure the TQ depended upon the simulated limb circumference. In the 1-year-old CPR manikin, all windlass TQs failed to tighten on the upper extremity, while all TQs successfully tightened at the high leg and mid-thigh. With the exception of the CAT7 and the SOFTT-W at the mid-thigh, no windlass TQ was successfully tightened at any extremity location on the infant. The SWAT-T was successfully tightened over all sites of all CPR manikins except the infant. No windlass TQ was able to tighten on PVC pipe 5.75” circumference or smaller (age < 24 months upper extremity). All windlass TQs were tightened and secured on the 13.25” and 15.5” circumference PVC pipes (age 7–12 years lower extremity, age >13 years upper extremity). The SWAT-T was tightened on all PVC pipes.DiscussionThe current study suggests that commercial windlass TQs can be applied to upper and lower extremities of children aged 5 years and older at the 50%th percentile for limb circumference. In younger children, windlass TQ efficacy is variable. Further study is required to better understand the limitations of TQs in the youngest children, and to determine actual hemorrhage control efficacy.
Validation of Inertial Measurement Units for Upper Body Kinematics
The purpose of this study was to validate a commercially available inertial measurement unit (IMU) system against a standard lab-based motion capture system for the measurement of shoulder elevation, elbow flexion, trunk flexion/extension, and neck flexion/extension kinematics. The validation analyses were applied to 6 surgical faculty members performing a standard, simulated surgical training task that mimics minimally invasive surgery. Three-dimensional joint kinematics were simultaneously recorded by an optical motion capture system and an IMU system with 6 sensors placed on the head, chest, and bilateral upper and lower arms. The sensor-to-segment axes alignment was accomplished manually. The IMU neck and trunk IMU flexion/extension angles were accurate to within 2.9 ± 0.9 degrees and 1.6 ± 1.1°, respectively. The IMU shoulder elevation measure was accurate to within 6.8 ± 2.7° and the elbow flexion measure was accurate to within 8.2 ± 2.8°. In the Bland-Altman analyses, there were no significant systematic errors present; however, there was a significant inversely proportional error across all joints. As the gold standard measurement increased, the IMU underestimated the magnitude of the joint angle. This study reports acceptable accuracy of a commercially available IMU system; however, results should be interpreted as protocol specific.
Quantifying Intraoperative Workloads Across the Surgical Team Roles: Room for Better Balance?
Abstract Background Surgical performance, provider health, and patient safety can be compromised when workload demands exceed individual capability on the surgical team. The purpose of this study is to quantify and compare intraoperative workload among surgical team members. Methods Observations were conducted for an entire surgical day for 33 participating surgeons and their surgical team at one medical institution. Workload (mental, physical, case complexity, distractions, and case difficulty) was measured for each surgical team member using questions from validated questionnaires. Statistical analyses were performed with a mixed effects model. Results A total of 192 surgical team members participated in 78 operative cases, and 344 questionnaires were collected. Procedures with high surgeon mental and physical workload included endovascular and gastric surgeries, respectively. Ratings did not differ significantly among surgeons and residents, but scrub nurses physical demand ratings were 14–22 (out of 100) points lower than the surgeons, residents, and surgical assistants. Residents reported the highest mental workload, averaging 19–24 points higher than surgical assistants, scrub nurses, and circulating nurses. Mental and physical demands exceeded 50 points 28–45 % of the time for surgeons and residents. Workload did not differ between minimally invasive and open techniques. Conclusion The workload questionnaires are an effective tool for quantifying intraoperative workload across the surgical team to ensure mental and physical demands do not exceed thresholds where performance may decrease and injury risk increase. This tool has the potential to measure the safety of current procedures and drive design of workload interventions.