Back to Authors

Jing, Wenwen

0000-0003-1038-5509

Mayo Clinic

Center for Biosensors and Bioelectronics, The Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA.

Citations 5

Machine Learning-Assisted Rapid Optical Imaging for Label-Free CAR T-Cell Detection in Whole Blood
Yu, Nanxi , Zhou, Xinyu , Zhang, Fenni , Cortes, Eider F. Moreno, Lengerke-Diaz, Paula A. , Forero-Forero, José Vicente , Forzani, Erica , Castro, Januario E. , Wang, Shaopeng , Moreno-Cortes, Eider , Porter, Ryan M , Zhou, Xinyu , Jing, Wenwen , Zhang, Fenni , Moreno-Cortes, Eider F , Diaz, Paula A Lengerke , Forero, Jose V , Forzani, Erica S , Castro, Januario E , Wang, Shaopeng , Porter, Ryan M., Jing, Wenwen

Biosensors | April 24, 2026 | Volume: 16 | Issue: 5 | Pages: 240

10.3390/bios16050240 Get It

Chimeric antigen receptor (CAR) T-cell therapy is an effective treatment for hematologic malignancies. However, it is limited by high costs, risk of severe toxicities such as cytokine release syndrome and neurotoxicity, and heterogeneous patient responses. The current therapy monitoring depends largely on subjective symptom assessment, routine laboratory tests, and basic vital signs, without real-time, quantitative evaluation of CAR T-cell expansion or activation in clinical practice. This lack of timely immune monitoring hampers individualized care and contributes to increased treatment costs. To address this need, we present a proof-of-concept, label-free rapid optical imaging (ROI) biosensor with automated machine learning analysis for direct quantification of CAR T-cells from whole blood. This microfluidic platform integrates red blood cell (RBC) removal, CAR T-cell capture, and imaging-based quantification on a single chip, eliminating the need for centrifugation, staining, and operator-dependent interpretation. For validation, 50 μL whole blood samples spiked with Jurkat cells expressing CD19 CARs underwent RBC depletion by agglutination and microfiltration. The remaining blood components were then incubated on a sensor chip functionalized with recombinant CD19 protein. Captured CAR T-cells were imaged by brightfield microscopy and automatically enumerated using a machine learning algorithm trained on fluorescence-validated cells. The CD-19 cells’ capture performance was validated by flow cytometry and fluorescence imaging. The trained machine learning model validated at 88% sensitivity and 96% specificity. Buffer and whole blood calibration curves were established across clinically relevant concentrations (1–1000 cells/µL) with triple replicates. The results showed high correlation (0.975 and 0.990 R2) between the spiked concentration and the detected CAR T-cells, with a 95% certainty limit of detection (LOD) and quantification (LOQ) of 0.6 and 1.1 cells/µL for spiked buffer, and 14 and 67 cells/µL for spiked whole-blood, respectively.
Direct Antimicrobial Susceptibility Testing on Clinical Urine Samples by Optical Tracking of Single Cell Division Events
Zhang, Fenni , Jiang, Jiapei, McBride, Michelle, Yang, Yunze , Mo, Manni , Iriya, Rafael , Peterman, Joseph, Jing, Wenwen , Haydel, Shelley E. , Tao, Nongjian , Grys, Thomas, Zhang, Fenni , Haydel, Shelley E , Jing, Wenwen , Grys, Thomas E. , Wang, Shaopeng

Small | November 30, 2020 | Volume: 16 | Issue: 52 | Pages: No page available

10.1002/smll.202004148 Get It

Abstract With the increasing prevalence of antibiotic resistance, the need to develop antimicrobial susceptibility testing (AST) technologies is urgent. The current challenge has been to perform the antibiotic susceptibility testing in short time, directly with clinical samples, and with antibiotics over a broad dynamic range of clinically relevant concentrations. Here, a technology for point‐of‐care diagnosis of antimicrobial‐resistant bacteria in urinary tract infections, by imaging the clinical urine samples directly with an innovative large volume solution scattering imaging (LVSi) system and analyzing the image sequences with a single‐cell division tracking method is developed. The high sensitivity of single‐cell division tracking associated with large volume imaging enables rapid antibiotic susceptibility testing directly on the clinical urine samples. The results demonstrate direct detection of bacterial infections in 60 clinical urine samples with a 60 min LVSi video, and digital AST of 30 positive clinical samples with 100% categorical agreement with both the clinical culture results and the on‐site agar plating validation results. This technology provides opportunities for precise antibiotic prescription and proper treatment of the patient within a single clinic visit.
Gradient-Based Rapid Digital Immunoassay for High-Sensitivity Cardiac Troponin T (hs-cTnT) Detection in 1 μL Plasma
Jing, Wenwen , Wang, Yi , Zhang, Fenni , Yang, Yunze , Ma, Guangzhong , Snozek, Christine, Tao, Nongjian , Chen, C.-H. , Zhang, Fenni , Ma, Guangzhong , Snozek, Christine L N, Wang, Shaopeng , Chen, Chao , Jing, Wenwen , Chen, Chao , Yang, Eric H. , Wang, Shaopeng

ACS Sensors | September 28, 2020 | Volume: 6 | Issue: 2 | Pages: 399-407

10.1021/acssensors.0c01681 Get It

Rapid Antimicrobial Susceptibility Testing of Patient Urine Samples Using Large Volume Free-Solution Light Scattering Microscopy
Mo, Manni , Yang, Yunze , Zhang, Fenni , Jing, Wenwen , Iriya, Rafael , Popovich, John, Grys, Thomas E. , Haydel, Shelley E. , Tao, Nongjian , Wang, Shaopeng , Grys, Thomas, Zhang, Fenni , Haydel, Shelley E , Grys, Thomas E , Popovich, John, Wang, Shaopeng , Jing, Wenwen

Analytical Chemistry | June 28, 2019 | Volume: 91 | Issue: 15 | Pages: 10164-10171

10.1021/acs.analchem.9b02174 Get It

Phenotypic Antimicrobial Susceptibility Testing with Deep Learning Video Microscopy
Yu, Hui , Jing, Wenwen , Iriya, Rafael , Yang, Yunze , Syal, Karan , Mo, Manni , Grys, Thomas E. , Tao, Nongjian , Wang, Shaopeng , Yu, Hui , Haydel, Shelley E. , Wang, Shaopeng , Grys, Thomas E , Jing, Wenwen

Analytical Chemistry | April 20, 2018 | Volume: 90 | Issue: 10 | Pages: 6314-6322

10.1021/acs.analchem.8b01128 Get It