Back to Authors

Jiang, Jiapei

Mayo Clinic

Arizona State University

Citations 4

Label‐Free Single‐Molecule Immunoassay
Chen, Chao , Zhou, Shuang , Chemerkouh, Mohammad Javad Haji Najafi , Snozek, Christine L.H. , Jiang, Jiapei, Braswell, Brandyn, Chen, C.-H. , Wang, Shaopeng , Chen, Chao , Zhou, Xiaoyan , Ma, Guangzhong , Yang, Eric H. , Wan, Zijian , Zhou, Xinyu , Wang, Shaopeng

Advanced Science | June 20, 2025 | Volume: 12 | Issue: 31 | Pages: No page available

10.1002/advs.202505207 Get It

Abstract Single‐molecule immunoassay is a reliable technique for the detection and quantification of low‐abundance blood biomarkers, which are essential for early disease diagnosis and biomedical research. However, current single‐molecule methods predominantly rely on endpoint detection and necessitate signal amplification via labeling, which brings a variety of unwanted effects, like matrix effect and autofluorescence interference. This study introduces a real‐time mass imaging‐based label‐free single‐molecule immunoassay (LFSMiA). Featuring plasmonic scattering microscopy‐based mass imaging, a 2‐step sandwich assay format enables background reduction, minimization of matrix effect by dynamic tracking of single binding events, and fully leveraging real‐time data for improved measurement precision through a Bayesian Gaussian process model, the LFSMiA enables ultra‐sensitive and direct protein detection at the single‐molecule level in neat blood sample matrices. LFSMiA measurement is demonstrated for interleukin‐6 and prostate‐specific antigen in buffer, undiluted serum, and whole blood with sub‐femtomolar detection limits and eight logs of dynamic ranges. Moreover, comparable performance is achieved with an inexpensive miniaturized setup. To show its translational potential to clinical settings and point‐of‐care diagnostics, N‐terminal pro‐B‐type natriuretic peptide is examined in patient whole blood samples using the LFSMiA and results in a strong linear correlation (r > 0.99) with standard clinical lab results.
Rapid Detection of Urinary Tract Infection in 10 min by Tracking Multiple Phenotypic Features in a 30 s Large-Volume Scattering Video of Urine Microscopy
Zhang, Fenni , Mo, Manni , Jiang, Jiapei, Zhou, Xinyu , McBride, Michelle, Yang, Yunze , Reilly, Kenta S., Haydel, Shelley E. , Tao, Nongjian , Grys, Thomas E. , Haydel, Shelley E , Wang, Shaopeng , Zhang, Fenni , Zhou, Xinyu , Wang, Shaopeng

ACS Sensors | August 5, 2022 | Volume: 7 | Issue: 8 | Pages: 2262-2272

10.1021/acssensors.2c00788 Get It

Abstract Rapid point-of-care (POC) diagnosis of bacterial infection diseases provides clinical benefits of prompt initiation of antimicrobial therapy and reduction of the overuse/misuse of unnecessary antibiotics for nonbacterial infections. We present here a POC compatible method for rapid bacterial infection detection in 10 min. We use a large-volume solution scattering imaging (LVSi) system with low magnifications (1–2×) to visualize bacteria in clinical samples, thus eliminating the need for culture-based isolation and enrichment. We tracked multiple intrinsic phenotypic features of individual cells in a short video. By clustering these features with a simple machine learning algorithm, we can differentiate Escherichia coli from similar-sized polystyrene beads, distinguish bacteria with different shapes, and distinguish E. coli from urine particles. We applied the method to detect urinary tract infections in 104 patient urine samples with a 30 s LVSi video, and the results showed 92.3% accuracy compared with the clinical culture results. This technology provides opportunities for rapid bacterial infection diagnosis at POC settings.
Rapid Antimicrobial Susceptibility Testing on Clinical Urine Samples by Video-Based Object Scattering Intensity Detection
Zhang, Fenni , Jiang, Jiapei, McBride, Michelle, Yang, Yunze , Mo, Manni , Peterman, Joseph, Tao, Nongjian , Mo, Manni , Grys, Thomas, Wang, Shaopeng , Zhang, Fenni , Zhou, Xinyu , Grys, Thomas E. , Haydel, Shelley E. , Wang, Shaopeng

Analytical Chemistry | April 28, 2021 | Volume: 93 | Issue: 18 | Pages: 7011-7021

10.1021/acs.analchem.1c00019 Get It

Direct Antimicrobial Susceptibility Testing on Clinical Urine Samples by Optical Tracking of Single Cell Division Events
Zhang, Fenni , Jiang, Jiapei, McBride, Michelle, Yang, Yunze , Mo, Manni , Iriya, Rafael , Peterman, Joseph, Jing, Wenwen , Haydel, Shelley E. , Tao, Nongjian , Grys, Thomas, Zhang, Fenni , Haydel, Shelley E , Jing, Wenwen , Grys, Thomas E. , Wang, Shaopeng

Small | November 30, 2020 | Volume: 16 | Issue: 52 | Pages: No page available

10.1002/smll.202004148 Get It

Abstract With the increasing prevalence of antibiotic resistance, the need to develop antimicrobial susceptibility testing (AST) technologies is urgent. The current challenge has been to perform the antibiotic susceptibility testing in short time, directly with clinical samples, and with antibiotics over a broad dynamic range of clinically relevant concentrations. Here, a technology for point‐of‐care diagnosis of antimicrobial‐resistant bacteria in urinary tract infections, by imaging the clinical urine samples directly with an innovative large volume solution scattering imaging (LVSi) system and analyzing the image sequences with a single‐cell division tracking method is developed. The high sensitivity of single‐cell division tracking associated with large volume imaging enables rapid antibiotic susceptibility testing directly on the clinical urine samples. The results demonstrate direct detection of bacterial infections in 60 clinical urine samples with a 60 min LVSi video, and digital AST of 30 positive clinical samples with 100% categorical agreement with both the clinical culture results and the on‐site agar plating validation results. This technology provides opportunities for precise antibiotic prescription and proper treatment of the patient within a single clinic visit.