Chimeric antigen receptor (CAR) T-cell therapy is an effective treatment for hematologic malignancies. However, it is limited by high costs, risk of severe toxicities such as cytokine release syndrome and neurotoxicity, and heterogeneous patient responses. The current therapy monitoring depends largely on subjective symptom assessment, routine laboratory tests, and basic vital signs, without real-time, quantitative evaluation of CAR T-cell expansion or activation in clinical practice. This lack of timely immune monitoring hampers individualized care and contributes to increased treatment costs. To address this need, we present a proof-of-concept, label-free rapid optical imaging (ROI) biosensor with automated machine learning analysis for direct quantification of CAR T-cells from whole blood. This microfluidic platform integrates red blood cell (RBC) removal, CAR T-cell capture, and imaging-based quantification on a single chip, eliminating the need for centrifugation, staining, and operator-dependent interpretation. For validation, 50 μL whole blood samples spiked with Jurkat cells expressing CD19 CARs underwent RBC depletion by agglutination and microfiltration. The remaining blood components were then incubated on a sensor chip functionalized with recombinant CD19 protein. Captured CAR T-cells were imaged by brightfield microscopy and automatically enumerated using a machine learning algorithm trained on fluorescence-validated cells. The CD-19 cells’ capture performance was validated by flow cytometry and fluorescence imaging. The trained machine learning model validated at 88% sensitivity and 96% specificity. Buffer and whole blood calibration curves were established across clinically relevant concentrations (1–1000 cells/µL) with triple replicates. The results showed high correlation (0.975 and 0.990 R2) between the spiked concentration and the detected CAR T-cells, with a 95% certainty limit of detection (LOD) and quantification (LOQ) of 0.6 and 1.1 cells/µL for spiked buffer, and 14 and 67 cells/µL for spiked whole-blood, respectively.
Abstract Single‐molecule immunoassay is a reliable technique for the detection and quantification of low‐abundance blood biomarkers, which are essential for early disease diagnosis and biomedical research. However, current single‐molecule methods predominantly rely on endpoint detection and necessitate signal amplification via labeling, which brings a variety of unwanted effects, like matrix effect and autofluorescence interference. This study introduces a real‐time mass imaging‐based label‐free single‐molecule immunoassay (LFSMiA). Featuring plasmonic scattering microscopy‐based mass imaging, a 2‐step sandwich assay format enables background reduction, minimization of matrix effect by dynamic tracking of single binding events, and fully leveraging real‐time data for improved measurement precision through a Bayesian Gaussian process model, the LFSMiA enables ultra‐sensitive and direct protein detection at the single‐molecule level in neat blood sample matrices. LFSMiA measurement is demonstrated for interleukin‐6 and prostate‐specific antigen in buffer, undiluted serum, and whole blood with sub‐femtomolar detection limits and eight logs of dynamic ranges. Moreover, comparable performance is achieved with an inexpensive miniaturized setup. To show its translational potential to clinical settings and point‐of‐care diagnostics, N‐terminal pro‐B‐type natriuretic peptide is examined in patient whole blood samples using the LFSMiA and results in a strong linear correlation (r > 0.99) with standard clinical lab results.
Rapid Detection
of Urinary Tract Infection in 10 min
by Tracking Multiple Phenotypic Features in a 30 s Large-Volume Scattering
Video of Urine Microscopy
Abstract Rapid point-of-care (POC) diagnosis of bacterial infection diseases provides clinical benefits of prompt initiation of antimicrobial therapy and reduction of the overuse/misuse of unnecessary antibiotics for nonbacterial infections. We present here a POC compatible method for rapid bacterial infection detection in 10 min. We use a large-volume solution scattering imaging (LVSi) system with low magnifications (1–2×) to visualize bacteria in clinical samples, thus eliminating the need for culture-based isolation and enrichment. We tracked multiple intrinsic phenotypic features of individual cells in a short video. By clustering these features with a simple machine learning algorithm, we can differentiate Escherichia coli from similar-sized polystyrene beads, distinguish bacteria with different shapes, and distinguish E. coli from urine particles. We applied the method to detect urinary tract infections in 104 patient urine samples with a 30 s LVSi video, and the results showed 92.3% accuracy compared with the clinical culture results. This technology provides opportunities for rapid bacterial infection diagnosis at POC settings.
Rapid Antimicrobial Susceptibility Testing on Clinical Urine Samples by Video-Based Object Scattering Intensity Detection