Aims We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years. Methods The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed. Results The cumulative incidence of any re-revision was 13% at a mean of ten years. At the most recent-follow-up, eight TKAs had been re-revised: three for recurrent flexion instability (two fully revised to varus-valgus constrained implants (VVCs), and one posterior-stabilized (PS) implant converted to VVC, one for global instability (PS to VVC), two for aseptic loosening of the femoral component, and two for periprosthetic joint infection). The ten-year cumulative incidence of any re-revision for instability was 7%. The median KSS improved significantly from 45 (interquartile range (IQR) 40 to 50) preoperatively to 70 (IQR 45 to 80) at a mean follow-up of ten years (p = 0.031). Radiologically, two patients, who had not undergone revision, had evidence of loosening (one tibial and one patellar). The remaining components were well fixed. Conclusion We found fair functional outcomes and implant survivorship at a mean of ten years after revision TKA for flexion instability with a PS implant. Recurrent instability and aseptic loosening were the most common indications for re-revision. Components with increased constraint, such as a VVC or hinged, should be used in these patients in order to reduce the risk of recurrent instability. Cite this article: Bone Joint J 2022;104-B(10):1126–1131.
Modular Fluted Tapered Stems for Periprosthetic Femoral Fractures
Background: Modular fluted tapered (MFT) stems have advanced treatment of Vancouver B 2 and B 3 periprosthetic femoral fractures, but series to date have been limited with respect to cohort size and follow-up duration. The purpose of this study was to determine implant survivorship, radiographic results, complications, and clinical outcomes of Vancouver B 2 and B 3 periprosthetic femoral fractures treated with MFT stems in a large series of patients. Methods: We identified 171 Vancouver B 2 (109) and B 3 (62) periprosthetic femoral fractures treated with an MFT stem between 2000 and 2018 using our institutional total joint registry. The mean age was 75 years, 50% were female, and the mean body mass index was 29 kg/m 2 . The median stem diameter was 18 mm and median stem length was 210 mm. The cumulative incidences of revision and reoperation with death as the competing risk were calculated, radiographs were reviewed, and clinical outcomes were evaluated using the Harris hip score (HHS). The mean follow-up was 5 years. Results: The 10-year cumulative incidence of any revision was 10%. There were 17 revisions, of which only 3 were for the distal fluted portion of the MFT stem. Revision indications included periprosthetic joint infection (PJI) (n = 6) and dislocation (n = 11). The 10-year cumulative incidence of any reoperation was 15%. In addition to the above 17 revisions, there were 7 reoperations for superficial wound complications (n = 4), Vancouver B 1 periprosthetic femoral fracture (n = 1), vascular occlusion (n = 1), and acetabular cartilage degeneration requiring an acetabular component (n = 1). Radiographically, there was 1 fracture nonunion. All unrevised MFT stems were radiographically well fixed. Subsidence of ≥5 mm occurred in 11%, but all implants were stable at the most recent follow-up. The mean HHS was 75 at 2 years (n = 71). Conclusions: In this large series of 171 Vancouver B 2 and B 3 periprosthetic femoral fractures treated with MFT stems, we found that such constructs were associated with a high rate of fracture healing and provided extremely reliable and durable implant fixation, with no revisions for aseptic loosening. Dislocation and PJI were the most common complications. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.