Object Considerable biological research has been performed to aid bone healing in conjunction with lumbar fusion surgery. Iliac crest autograft is often considered the gold standard because it has the vital properties of being osteoconductive, osteoinductive, and osteogenic. However, graft site pain has been widely reported as the most common donor site morbidity. Autograft site pain has led many companies to develop an abundance of bone graft extenders, which have limited proof of efficacy. During the surgical consent process, many patients ask surgeons to avoid harvesting autograft because of the reported pain complications. The authors sought to study postoperative graft site pain by simply asking patients whether they knew which iliac crest was grafted when a single skin incision was made for the fusion operation. Methods Twenty-five patients underwent iliac crest autografting with allograft reconstruction during instrumented lumbar fusion surgery. In all patients the autograft was harvested through the same skin incision but with a separate fascial incision. At various points postoperatively, the patients were asked if they could tell which iliac crest had been harvested, and if so, how much pain did it cause (10-point Numeric Rating Scale). Results Most patients (64%) could not correctly determine which iliac crest had been harvested. Of the 9 patients who correctly identified the side of the autograft, 7 were only able to guess. The 2 patients who confidently identified the side of grafting had no pain at rest and mild pain with activity. One patient who incorrectly guessed the side of autografting did have significant sacroiliac joint degenerative pain bilaterally. Conclusions Results of this study indicate the inability of patients to clearly define their graft site after iliac crest autograft harvest with allograft reconstruction of the bony defect unless they have a separate skin incision. This simple, easily reproducible pilot study can be expanded into a larger, multiinstitutional investigation to provide more definitive answers regarding the ideal, safe, and cost-effective bone graft material to be used in spinal fusions.
Synovial Cyst Mimicking an Intraspinal Sacral Mass
A 68-year-old female had a three-week history of severe low back pain radiating down the posterior left buttocks and left leg exacerbated by standing and walking. Lumbar spine MRI revealed cystic mass with similar intensity to cerebrospinal fluid located on dorsolateral left side of the sacral spinal canal inferior to the S1 pedicle. There was compression of left exiting S1 and traversing S2 nerve roots. Neurosurgery consult was requested to evaluate the cystic mass in the sacral spinal canal. After clinical evaluation, an unusually located synovial cyst was thought possible. Cyst contents were heterogeneous, suggestive of small hemorrhage and acute clinical history seemed reasonable. Left S1 and partial left S2 hemilaminectomy was performed and an epidural, partially hemorrhagic cyst was removed. There was no obvious connection to the ipsilateral L5-S1 facet joint. Pathology revealed synovial cyst, and the patient’s leg pain was improved postoperatively. This synovial cyst was unusual as it had no connection with the facet joint intraoperatively and its location in the sacral canal was uncommon.
Intraoperative image-guided spinal navigation: technical pitfalls and their avoidance
Spinal instrumentation has made significant advances in the last two decades, with transpedicular constructs now widely used in spinal fixation. Pedicle screw constructs are routinely used in thoracolumbar-instrumented fusions, and in recent years, the cervical spine as well. Three-column fixations with pedicle screws provide the most rigid form of posterior stabilization. Surgical landmarks and fluoroscopy have been used routinely for pedicle screw insertion, but a number of studies reveal inaccuracies in placement using these conventional techniques (ranging from 10% to 50%). The ability to combine 3D imaging with intraoperative navigation systems has improved the accuracy and safety of pedicle screw placement, especially in more complex spinal deformities. However, in the authors' experience with image guidance in more than 1500 cases, several potential pitfalls have been identified while using intraoperative spinal navigation that could lead to suboptimal results. This article summarizes the authors' experience with these various pitfalls using spinal navigation, and gives practical tips on their avoidance and management.
A case series on the technical use of three-dimensional image guidance in subaxial anterior cervical surgery
Symptomatic pneumocephalus is a rare complication of degenerative lumbar spine surgery. This is a case report of a patient who developed transient diplopia associated with pneumocephalus following lumbar spine surgery complicated by a dural tear. The diplopia improved as the pneumocephalus resolved. Factors involved in the development of pneumocephalus include an unintended durotomy and intraoperative reverse Trendelenburg positioning that was utilized to decrease the risk of postoperative vision loss. When encountering cerebrospinal fluid (CSF) leakage intraoperatively, spine surgeons should level the operating table until closure of the dural defect to prevent potential complications associated with pneumocephalus. If postoperative patients complain of severe headaches or display a focal cranial neurologic deficit, then a computed tomography (CT) scan of the brain should be ordered and evaluated. Consulting neurologists should be aware of the circumstances surrounding this rare complication.
Operating room radiation exposure in cone beam computed tomography–based, image-guided spinal surgery
Object Surgeon and operating room (OR) staff radiation exposure during spinal surgery is a concern, especially with the increasing use of multiplanar fluoroscopy in minimally invasive spinal surgery procedures. Cone beam computed tomography (cbCT)–based, 3D image guidance does not involve the use of active fluoroscopy during instrumentation placement and therefore decreases radiation exposure for the surgeon and OR staff during spinal fusion procedures. However, the radiation scatter of a cbCT device can be similar to that of a standard 64-slice CT scanner and thus could expose the surgeon and OR staff to radiation during image acquisition. The purpose of the present study was to measure radiation exposure at several unshielded locations in the OR when using cbCT in conjunction with 3D image-guided spinal surgery in 25 spinal surgery cases. Methods Five unshielded badge dosimeters were placed at set locations in the OR during 25 spinal surgery cases in which cbCT-based, 3D image guidance was used. The cbCT device (O-ARM) was used in conjunction with the Stealth S7 image-guided platform. The radiology department analyzed the badge dosimeters after completion of the last case. Results Fifty high-definition O-ARM spins were performed in 25 patients for spinal registration and to check instrumentation placement. Image-guided placement of 124 screws from C-2 to the ileum was accomplished without complication. Badge dosimetry analysis revealed minimal radiation exposure for the badges 6 feet from the gantry in the area of the anesthesiology equipment, as well as for the badges located 10–13 feet from the gantry on each side of the room (mean 0.7–3.6 mrem/spin). The greatest radiation exposure occurred on the badge attached to the OR table within the gantry (mean 176.9 mrem/spin), as well as on the control panel adjacent to the gantry (mean 128.0 mrem/spin). Conclusions Radiation scatter from the O-ARM was minimal at various distances outside of and not adjacent to the gantry. Although the average radiation exposure at these locations was low, an earlier study, undertaken in a similar fashion, revealed no radiation exposure when the surgeon stood behind a lead shield. This simple precaution can eliminate the small amount of radiation exposure to OR staff in cases in which the O-ARM is used.
Tumor Haze Caused a Missed Shave: Facial Shaving Hemineglect