Back to Authors

Pichelmann, Mark

Mayo Clinic

Department of Neurosurgery, Mayo Clinic, Jacksonville, Florida.

Citations 8

International Learner Perceptions, Educational Value, and Cost Associated With the Use of Start-to-Finish Surgical Simulation Compared With Cadaveric Models
Damon, Aaron , Pichelmann, Mark A., Nottmeier, Eric W. , CreveCoeur, Travis S. , Lee, Seung-Jin, Pichelmann, Mark, Nottmeier, Eric, Lee, Seung Jin , Clifton, William

Operative Neurosurgery | January 13, 2023 | Volume: 24 | Issue: 2 | Pages: 201-208

10.1227/ons.0000000000000475 Get It

BACKGROUND: Graduate surgical education is highly variable across regions and institutions regarding case volume and degree of trainee participation in each case. Dedicated educational curriculum using cadaveric tissue has been shown to enhance graduate surgical training, however with associated financial and utility burden to the institution. OBJECTIVE: To investigate the utility of educational and cost applications of a novel method of combining mixed organic hydrogel polymers and 3-dimensional printed anatomic structures to create a complete “start-to-finish” simulation for resident education in spinal anatomy, instrumentation, and surgical techniques. METHODS: This qualitative pilot study investigated 14 international participants on achievement of objective and personal learning goals in a standardized curriculum using biomimetic simulation compared with cadaveric tissue. A questionnaire was developed to examine trainee evaluation of individual anatomic components of the biomimetic simulators compared with previous experience with cadaveric tissue. RESULTS: A total of 210 responses were acquired from 14 participants. Six participants originated from US residency education programs and 8 from transcontinental residency programs. Survey results for the simulation session revealed high user satisfaction. Score averages for each portion of the simulation session indicated learner validation of anatomic features for the simulation compared with previous cadaveric experience. Cost analysis resulted in an estimated savings of $10 833.00 for this single simulation session compared with previous cadaveric tissue sessions. CONCLUSION: The results of this study indicate a strong potential of establishing biomimetic simulation as a cost-effective and high-quality alternative to cadaveric tissue for the instruction of fundamental spine surgical techniques.
Investigation of a three‐dimensional printed dynamic cervical spine model for anatomy and physiology education
Clifton, William , Damon, Aaron , Soares, Christy, Nottmeier, Eric W. , Pichelmann, Mark A., Nottmeier, Eric, Pichelmann, Mark, Clifton, William E

Clinical Anatomy | April 21, 2020 | Volume: 34 | Issue: 1 | Pages: 30-39

10.1002/ca.23607 Get It

AbstractIntroductionThree‐dimensional (3D) printing of anatomical structures is a growing method of education for students and medical trainees. These models are generally produced as static representations of gross surface anatomy. In order to create a model that provides educators with a tool for demonstration of kinematic and physiologic concepts in addition to surface anatomy, a high‐resolution segmentation and 3D‐printingtechnique was investigated for the creation of a dynamic educational model.MethodsAn anonymized computed tomography scan of the cervical spine with a diagnosis of ossification of the posterior longitudinal ligament was acquired. Using a high‐resolution thresholding technique, the individual facet and intervertebral spaces were separated, and models of the C3–7 vertebrae were 3D‐printed. The models were placed on a myelography simulator and subjected to flexion and extension under fluoroscopy, and measurements of the spinal canal diameter were recorded and compared to in‐vivo measurements. The flexible 3D‐printed model was then compared to a static 3D‐printed model to determine the educational benefit of demonstrating physiologic concepts.ResultsThe canal diameter changes on the flexible 3D‐printed model accurately reflected in‐vivo measurements during dynamic positioning. The flexible model also was also more successful in teaching the physiologic concepts of spinal canal changes during flexion and extension than the static 3D‐printed model to a cohort of learners.ConclusionsDynamic 3D‐printed models can provide educators with a cost‐effective and novel educational tool for not just instruction of surface anatomy, but also physiologic concepts through 3D ex‐vivo modeling of case‐specific physiologic and pathologic conditions.
Microanatomical considerations for safe uncinate removal during anterior cervical discectomy and fusion: 10‐year experience
Clifton, William , Valero‐Moreno, Fidel, Vlasak, Alexander , Damon, Aaron , Tubbs, R. Shane , Merrill, Sarah , Pichelmann, Mark A., Pichelmann, Mark, Clifton, William E

Clinical Anatomy | April 2, 2020 | Volume: 33 | Issue: 6 | Pages: 920-926

10.1002/ca.23596 Get It

AbstractCervical radiculopathy from uncovertebral joint (UVJ) hypertrophy and nerve root compression often occurs anterior and lateral within the cervical intervertebral foramen, presenting a challenge for complete decompression through anterior cervical approaches owing to the intimate association with the vertebral artery and associated venous plexus. Complete uncinatectomy during anterior cervical discectomy and fusion (ACDF) is a controversial topic, many surgeons relying on indirect nerve root decompression from restoration of disc space height. However, in cases of severe UVJ hypertrophy, indirect decompression does not adequately address the underlying pathophysiology of anterolateral foraminal stenosis. Previous reports in the literature have described techniques involving extensive dissection of the cervical transverse process and lateral uncinate process (UP) in order to identify the vertebral artery for safe removal of the UP. Recent anatomical investigations have detailed the microanatomical organization of the fibroligamentous complex surrounding the UP and neurovascular structures. The use of the natural planes formed from the encapsulation of these connective tissue layers provides a safe passage for lateral UP dissection during anterior cervical approaches. This can be performed from within the disc space during ACDF to avoid extensive lateral dissection. In this article, we present our 10‐year experience using an anatomy‐based microsurgical technique for safe and complete removal of the UP during ACDF for cervical radiculopathy caused by UVJ hypertrophy.
Ex vivo virtual and 3D printing methods for evaluating an anatomy‐based spinal instrumentation technique for the 12th thoracic vertebra
Clifton, William , Nottmeier, Eric W. , ReFaey, Karim , Damon, Aaron , Vlasak, Alexander , Tubbs, R. Shane , Clifton, Christopher L., Pichelmann, Mark A., Nottmeier, Eric, Pichelmann, Mark, Clifton, William E , ReFaey, Karim

Clinical Anatomy | January 15, 2020 | Volume: 33 | Issue: 3 | Pages: 458-467

10.1002/ca.23562 Get It

AbstractIntroductionThree‐dimensional printing and virtual simulation both provide useful methods of patient‐specific anatomical modeling for assessing and validating surgical techniques. A combination of these two methods for evaluating the feasibility of spinal instrumentation techniques based on anatomical landmarks has not previously been investigated.Materials and MethodsNineteen anonymized CT scans of the thoracic spine in adult patients were acquired. Maximum pedicle width and height were recorded, and statistical analysis demonstrated normal distributions. The images were converted into standard tessellation language (STL) files, and the T12 vertebrae were anatomically segmented. The intersection of two diagonal lines drawn from the lateral and medial borders of the T12 transverse process (TP) to the lateral border of the pars and inferolateral portion of the TP was identified on both sides of each segmented vertebra. A virtual screw was created and insertion into the pedicle on each side was simulated using the proposed landmarks. The vertebral STL files were then 3D‐printed, and 38 pedicles were instrumented according to the individual posterior landmarks used in the virtual investigation.ResultsThere were no pedicle breaches using the proposed anatomical landmarks for insertion of T12 pedicle screws in the virtual simulation component. The technique was further validated by additive manufacturing of individual T12 vertebrae and demonstrated no breaches or model failures during live instrumentation using the proposed landmarks.ConclusionsEx vivo modeling through virtual simulation and 3D printing provides a powerful and cost‐effective means of replicating vital anatomical structures for investigation of complex surgical techniques.
3-Dimensionally Printed Biomimetic Surgical Simulation—Operative Technique of a Transforaminal Lumbar Interbody Fusion: 2-Dimensional Operative Video
Clifton, William , Damon, Aaron , Nottmeier, Eric W. , Pichelmann, Mark A., Nottmeier, Eric, Pichelmann, Mark, Clifton, William E

Operative Neurosurgery | December 12, 2019 | Volume: 19 | Issue: 2 | Pages: E153-E153

10.1093/ons/opz398 Get It

Abstract We present a surgical video highlighting the technical demonstration and microsurgical anatomy of an L4-5 transforaminal lumbar interbody fusion utilizing a combination of thermoplastic polymers and 3-dimensional printing technology to create a biomimetic lumbar spine surgical simulator. The posterior elements of L4-5 and the inferior portion of L3 are exposed in their entirety, including the transverse processes in order to identify the appropriate landmarks for pedicle screw insertion. The interspinous ligament of L4-5 is removed, and an interlaminar spreader is used to distract the facet joint. An inferior L4 facetectomy is performed for local autograft harvesting. The L4 and L5 pedicles are skeletonized to completely open the foramen in order to ensure that the exiting nerve root will not be compromised during cage insertion. The ligamentum flavum is then removed, exposing the common thecal sac and L5 traversing root. The L4 exiting nerve root is then identified, completing Kambin's triangle and location of the disc space. The disc is incised, and a combination of punches and curettes are used to completely remove the disc. After an interbody trial is used to assess the proper cage size, the cage is packed with graft and inserted into the midline of the disc space. Pedicle screws are then placed using an anatomic freehand technique, and intraoperative fluoroscopy is performed in order to evaluate the instrumentation and interbody position. If a contralateral decompression is required, a facet-sparing technique is performed in order to preserve bony surface for the fusion. Patient consent was not required for this simulation video.
The importance of teaching clinical anatomy in surgical skills education: Spare the patient, use a sim!
Clifton, William , Damon, Aaron , Nottmeier, Eric W. , Pichelmann, Mark A., Nottmeier, Eric, Pichelmann, Mark, Clifton, William E

Clinical Anatomy | October 3, 2019 | Volume: 33 | Issue: 1 | Pages: 124-127

10.1002/ca.23485 Get It

Anatomical knowledge is a key tenet in graduate medical and surgical education. Classically, these principles are taught in the operating room during live surgical experience. This puts both the learner and the patient at a disadvantage due to environment, time, and safety constraints. Educational adjuncts such as cadaveric courses and surgical skills didactics have been shown to improve resident confidence and proficiency in both anatomical knowledge and surgical techniques. However, the cost‐effectiveness of these courses is a limiting factor and in many cases prevents implementation within institutional training programs. Anatomical simulation in the form of “desktop” three‐dimensional (3D) printing provides a cost‐effective adjunct while maintaining educational value. This article describes the anatomical and patient‐centered approach that led to the establishment of our institution's 3D printing laboratory for anatomical and procedural education. Clin. Anat. 32:124–127, 2019. © 2019 Wiley Periodicals, Inc.
Techniques and Tips for Freehand Placement of C7 Pedicle Screws With Respect to Cervicothoracic Constructs: 2-Dimensional Operative Video
Clifton, William , Edwards, Steve, Louie, Christopher, Dove, Conrad, Damon, Aaron , Nottmeier, Eric W. , Pichelmann, Mark A., Nottmeier, Eric, Pichelmann, Mark, Clifton, William E

Operative Neurosurgery | August 23, 2019 | Volume: 18 | Issue: 6 | Pages: E234-E234

10.1093/ons/opz235 Get It

Abstract We present a surgical video highlighting the technical pearls for C7 pedicle screw placement with respect to cervicothoracic constructs. Pedicle screw placement into C7 has been shown to enhance the biomechanical stability of both cervical and cervicothoracic constructs and is safe for patient related outcomes. 1 , 2 Rod placement across the cervicothoracic junction is known to be difficult because of the variable starting point of the C7 pedicle screw, which may cause misalignment of the polyaxial heads with respect to the C7 and C6 screw heads. Using our step-wise method of anatomic screw placement, this potential pitfall is minimized. The T1 pedicle screw is placed first. The C6 lateral mass screw starting point is displaced slightly superiorly from the midpoint of the lateral mass in order to make room for the polyaxial head of the C7 pedicle screw. A small laminotomy is performed in order to find the medial border of the C7 pedicle. Palpation of the medial border allows for an approximation of the pedicle limits. The cranial-caudal angle of drilling is perpendicular to the C7 superior facet, and the medial-lateral trajectory typically falls between 15 and 20 degrees medial. Once the pedicle is cannulated, a ball-tipped probe is used to confirm intraosseous position. A rod is cut and contoured to the appropriate length of the construct. The C7 pedicle screw should capture the rod easily with slight displacement of the polyaxial head. Postinstrumentation anteroposterior and lateral fluoroscopy are performed to confirm good position of the lateral mass and pedicle screws. Patient consent was not required for this cadaveric surgical video.
Radiographic comparison of cross-sectional lumbar pedicle fill when placing screws with navigation versus free-hand technique
Pirris, Stephen M. , Nottmeier, Eric W. , O’Brien, Michael, Rahmathulla, Gazanfar , Pichelmann, Mark A., Pichelmann, Mark

The International Journal of Medical Robotics and Computer Assisted Surgery | May 4, 2015 | Volume: 12 | Issue: 2 | Pages: 309-315

10.1002/rcs.1666 Get It