Introduction: Our study assesses the utility of telemetry in identifying decompensation in patients with documented cardiopulmonary arrest. Methods: A retrospective review of inpatients who experienced a cardiopulmonary arrest from May 1, 2008, until June 30, 2014, was performed. Telemetry records 24 hours prior to and immediately preceding cardiopulmonary arrest were reviewed. Patient subanalyses based on clinical demographics were made as well as analyses of survival comparing patients with identifiable rhythm changes in telemetry to those without. Results: Of 242 patients included in the study, 75 (31.0%) and 110 (45.5%) experienced telemetry changes at the 24-hour and immediately preceding time periods, respectively. Of the telemetry changes, the majority were classified as nonmalignant (n = 50, 66.7% and n = 66, 55.5% at 24 hours prior and immediately preceding, respectively). There was no difference in telemetry changes between intensive care unit (ICU) and non-ICU patients and among patients stratified according to the American Heart Association telemetry indications. There was no difference in survival when comparing patients with telemetry changes immediately preceding and at 24 hours prior to an event (n = 30, 27.3% and n = 15, 20.0%) to those without telemetry changes during the same periods (n = 27, 20.5% and n = 42, 25.2%; P = .22 and .39). Conclusion: Telemetry has limited utility in predicting clinical decompensation in the inpatient setting.
Operating room radiation exposure in cone beam computed tomography–based, image-guided spinal surgery
Object Surgeon and operating room (OR) staff radiation exposure during spinal surgery is a concern, especially with the increasing use of multiplanar fluoroscopy in minimally invasive spinal surgery procedures. Cone beam computed tomography (cbCT)–based, 3D image guidance does not involve the use of active fluoroscopy during instrumentation placement and therefore decreases radiation exposure for the surgeon and OR staff during spinal fusion procedures. However, the radiation scatter of a cbCT device can be similar to that of a standard 64-slice CT scanner and thus could expose the surgeon and OR staff to radiation during image acquisition. The purpose of the present study was to measure radiation exposure at several unshielded locations in the OR when using cbCT in conjunction with 3D image-guided spinal surgery in 25 spinal surgery cases. Methods Five unshielded badge dosimeters were placed at set locations in the OR during 25 spinal surgery cases in which cbCT-based, 3D image guidance was used. The cbCT device (O-ARM) was used in conjunction with the Stealth S7 image-guided platform. The radiology department analyzed the badge dosimeters after completion of the last case. Results Fifty high-definition O-ARM spins were performed in 25 patients for spinal registration and to check instrumentation placement. Image-guided placement of 124 screws from C-2 to the ileum was accomplished without complication. Badge dosimetry analysis revealed minimal radiation exposure for the badges 6 feet from the gantry in the area of the anesthesiology equipment, as well as for the badges located 10–13 feet from the gantry on each side of the room (mean 0.7–3.6 mrem/spin). The greatest radiation exposure occurred on the badge attached to the OR table within the gantry (mean 176.9 mrem/spin), as well as on the control panel adjacent to the gantry (mean 128.0 mrem/spin). Conclusions Radiation scatter from the O-ARM was minimal at various distances outside of and not adjacent to the gantry. Although the average radiation exposure at these locations was low, an earlier study, undertaken in a similar fashion, revealed no radiation exposure when the surgeon stood behind a lead shield. This simple precaution can eliminate the small amount of radiation exposure to OR staff in cases in which the O-ARM is used.
Surgeon radiation exposure in cone beam computed tomography‐based, image‐guided spinal surgery