We undertook this study to determine the minimum amount of coronoid necessary to stabilise an otherwise intact elbow joint. Regan–Morrey types II and III, plus medial and lateral oblique coronoid fractures, collectively termed type IV fractures, were simulated in nine fresh cadavers. An electromagnetic tracking system defined the three-dimensional stability of the ulna relative to the humerus. The coronoid surface area accounts for 59% of the anterior articulation. Alteration in valgus, internal and external rotation occurred only with a type III coronoid fracture, accounting for 68% of the coronoid and 40% of the entire articular surface. A type II fracture removed 42% of the coronoid articulation and 25% of the entire articular surface but was associated with valgus and external rotational changes only when the radial head was removed, thereby removing 67% of the articular surface. We conclude that all type III fractures, as defined here, are unstable, even with intact ligaments and a radial head. However, a type II deficiency is stable unless the radial head is removed. Our study suggests that isolated medial-oblique or lateral-oblique fractures, and even a type II fracture with intact ligaments and a functional radial head, can be clinically stable, which is consistent with clinical observation.
Effect of Posteroinferior Capsule Tightness on Contact Pressure and Area beneath the Coracoacromial Arch during Pitching Motion
Background Tightness of the posteroinferior capsule is assumed to be the cause of internal rotation loss in baseball pitchers. Although the relationship between posterior capsule and subacromial impingement has been recognized, this relationship during the baseball-pitching motion is unclear. Hypothesis Contact pressure during baseball-pitching motion increases with posterior capsule tightness. Study Design Controlled laboratory study. Methods Eight fresh-frozen shoulders were used. The peak contact pressure and area on the coracoacromial arch were measured on a custom-designed shoulder experimental device capable of 6 degrees of freedom motion. Simultaneously, the sites of peak pressure on the coracoacromial arch and humerus were observed from various angles. The posteroinferior capsule tightness was simulated by plicating the capsule in the region from 6 to 8 o'clock. The static testing positions correlated to the early cocking, late cocking, acceleration, deceleration, and follow-through phases of the pitching motion. Results The peak contact pressure during the follow-through phase (0.63 ± 0.50 MPa) significantly increased with posteroinferior capsule tightness (1.00 ± 0.65 MPa) (P = .014). Additionally, the contact area on the coracoacromial ligament during the follow-through phase (0.98 ± 0.67 cm2) significantly increased with posteroinferior capsule tightness (1.47 ± 0.91 cm 2) (P < .001). The site of the peak contact pressure did not change between the 2 conditions. Conclusion Our findings demonstrate that posteroinferior capsule tightness leads to higher contact pressure under the subacromial arch and increased contact area, particularly on the coracoacromial ligament during the follow-through phase. Clinical Relevance This tightness may affect risk of injury of the rotator cuff and its surrounding tissues by increasing subacromial contact during pitching.
The Addition of Rotator Interval Closure after Arthroscopic Repair of Either Anterior or Posterior Shoulder Instability
Background Although the use of rotator interval closure is frequently advocated as a useful supplement to shoulder instability repairs, the addition of a rotator interval closure after arthroscopic instability repair has not been fully investigated. Purpose The objective of this study was to investigate whether a rotator interval closure improves glenohumeral stability in an anterior and posterior instability shoulder model. Study Design Controlled laboratory study. Methods Fourteen fresh-frozen cadaveric shoulder specimens were dissected free of soft tissues, leaving the rotator cuff intact with simulated cuff loading. All specimens were mounted in a custom testing apparatus using infrared sensors to document glenohumeral translation and rotation. The specimens were then tested for stability in the following order: vented/subluxated state, after arthroscopic anterior (Group 1; 7 specimens) or posterior (Group 2; 7 specimens) instability repair with suture anchors, and then after rotator interval closure. For each of the 3 testing conditions, the following were measured: (1) external and internal rotation at neutral, (2) external and internal rotation at 90° of abduction, (3) posterior and anterior translation at neutral rotation (15 N and 25 N), (4) anterior translation at 90° of abduction and external rotation (Group 1; 15 N and 25 N), (5) posterior translation at 90° of flexion and internal rotation (Group 2; 15 N and 25 N), and (6) sulcus testing in neutral (7.5 N). Results Posterior stability was only improved after anchor capsulolabral repair (8.0 to 5.0 mm; P = .017, 25 N), but there was no improvement after rotator interval closure (5.0 to 4.6 mm; P = .453). However, anterior stability was improved after capsulolabral repair (8.6 to 4.0 mm; P = .016, 25 N) and also improved further by rotator interval closure (4.0 to 2.4 mm; P = .007). The mean loss of external rotation was significantly increased by the addition of the rotator interval closure in both neutral and abducted glenohumeral positions, with a mean external rotation loss of 28° in neutral ( P = .013). The addition of a rotator interval closure did not improve sulcus stability ( P = .4). Conclusion The addition of an arthroscopic rotator interval closure after posterior capsulolabral repair did not improve posterior stability; however, anterior stability was improved further after a rotator interval closure. Inferior stability was not improved. Arthroscopic rotator interval closure significantly decreased external rotation at both neutral and abducted arm positions. Clinical Relevance Arthroscopic closure may be beneficial in certain cases of anterior shoulder instability; however, posterior instability was not improved. Predictable losses of external rotation after rotator interval closure are of concern.
Arthroscopic Versus Open Rotator Interval Closure: Biomechanical Evaluation of Stability and Motion
Purpose The purposes of this study were to investigate the differences between open and arthroscopic closure of the rotator interval (RI) on glenohumeral translation and range of motion. We also sought to determine if the addition of either an open or arthroscopic RI closure increases stability of the shoulder. Methods Fourteen fresh‐frozen (10 paired) cadaveric shoulder specimens were mounted in a custom testing apparatus, and glenohumeral translation and rotation were obtained by using an optoelectric tracking system (Optotrak Certus; Northern Digital, Ontario, Canada). Specimens were randomly allocated to either open (n = 7) or arthroscopic (n = 7) plication of the RI. The following were measured first with an intact and vented specimen and subsequently after an RI closure using either open or arthroscopic techniques: (1) range of motion in neutral and 90° abduction; (2) anterior and posterior translation at neutral rotation; (3) anterior translation at 90° abduction with external rotation; and (4) posterior translation at 90° flexion with internal rotation. Results Posterior stability was not improved from the intact state by either open (1.0‐mm change) or arthroscopic (0.1‐mm change) repair. The sulcus stability was improved in the open group (5.7 mm to 2.9 mm, P = .028), but not arthroscopically (5.1 to 4.1 mm, P = .499). Neutral anterior stability was improved after open repair (7.2 to 2.6 mm, P = .018), but not arthroscopically (2.3 to 2.4 mm, P = 0.5). However, anterior stability in external rotation (ER) at 90° abduction was improved in the arthroscopic repair group (5.5 to 3.1 mm, P = .006). The mean loss of ER in neutral was greater in the open group (40.8°) versus the arthroscopic group (24.4°, P = .0038). The arthroscopic group showed an 11.7° loss of ER in 90° abduction ( P = .018) versus the open group loss of 4.8°. There were no significant differences in loss of IR in either neutral or 90° abduction. Conclusions Posterior stability was not improved by either open or arthroscopic rotator interval repair, and sulcus stability only improved with the open technique. Anterior stability in neutral was improved after open repair and in the arthroscopic repair group with the arm abducted. There was a large loss of external rotation with both techniques. Clinical Relevance This study suggests that arthroscopic RI closure adds little to the overall posterior and inferior stability of the shoulder joint, although anterior stability may be improved. There is a potentially large loss of external rotation after either repair method.
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | November 18, 2003 | Volume: 217 | Issue: 5 | Pages: 405-414
Wheelchair propulsion is a man-machine interaction in which chair design and fit affect the relative positions and orientations of the upper extremity relative to the handrim and wheel axle. To understand these relationships better, experimental data were collected in five hand positions from five subjects exerting maximal effort to propel an instrumented wheelchair with its wheel in a locked position. The results of experiments revealed that the progression moment was greater at both initial and terminal propulsion positions and smaller in the mid-propulsion position. The vertical and horizontal force components were directed radially away from the wheel axle posterior to the dead centre position and radially towards the wheel axle anterior to top dead centre. Subsequently, a subject-specific quasi-static model of the upper extremity which maximized wheel progression moment was developed to augment our understanding of experimental measures. Model-predicted trends in progression moments and hand force direction were similar to experiment. Model predictions revealed that the optimal progression moment generation could potentially be affected by an individual's anthropometric parameters, joint strengths and also the direction of force applied by the hand on the handrim. Through wheelchair fitting and training of wheelchair users, it may be possible to improve propulsion technique.