Cardiac Electrophysiology, Mount Sinai Fuster Heart Hospital, New York, NY (V.Y.R.).
Citations 14
Lesion Size and Safety Comparison Between the Novel Flex Tip on the FlexAbility Ablation Catheter and the Solid Tips on the ThermoCool and ThermoCool SF Ablation Catheters
Flex Tip Comparative AblationIntroductionNext‐generation catheters have been developed to reduce irrigation volume and preserve power delivery. A novel design uses a flexible tip (FlexAbility™ catheter) that directs flow to the contact surface. Because of recent safety issues with new catheters, we undertook a study in a canine heart with 3 irrigated catheters to compare efficacy and safety.MethodsEndocardial ablation was performed by 2 independent operators in 12 anesthetized canines with the FlexAbility (St. Jude Medical), ThermoCool™ (Biosense Webster), and ThermoCool™ SF (Biosense Webster) catheters. Endocardial RF lesions were delivered with each catheter in all 4 chambers of each animal for 52 ± 16 seconds. Each chamber was randomized to receive ablation from one catheter with recording of safety events. Cardiac pathology was performed with triphenyl tetrazolium chloride stain.ResultsAverage lesion dimensions were not significantly different between the 3 catheters. FlexAbility™ demonstrated a lower risk of steam pops relative to ThermoCool SF (P‐value = 0.013) despite equal mean power and radiofrequency time. High‐temperature generator shutdowns were observed with FlexAbility™ but not with either ThermoCool catheter. High‐temperature shutdowns were associated with larger average impedance drops (28.5 ohms vs. 19 ohms) without compromising lesion size.ConclusionsThe FlexAbility™ tip is safe and effective with no significant difference in lesion sizes compared to both standard ThermoCool and ThermoCool SF. FlexAbility™ has a significantly lower risk of steam pops compared to ThermoCool SF in a beating heart as defined predominantly by an abrupt rise of impedance.
Percutaneous Left Atrial Appendage Closure vs Warfarin for Atrial Fibrillation
Background— The multicenter PROTECT AF study (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) was conducted to determine whether percutaneous left atrial appendage closure with a filter device (Watchman) was noninferior to warfarin for stroke prevention in atrial fibrillation. Methods and Results— Patients (n=707) with nonvalvular atrial fibrillation and at least 1 risk factor (age >75 years, hypertension, heart failure, diabetes, or prior stroke/transient ischemic attack) were randomized to either the Watchman device (n=463) or continued warfarin (n=244) in a 2:1 ratio. After device implantation, warfarin was continued for ≈45 days, followed by clopidogrel for 4.5 months and lifelong aspirin. Study discontinuation rates were 15.3% (71/463) and 22.5% (55/244) for the Watchman and warfarin groups, respectively. The time in therapeutic range for the warfarin group was 66%. The composite primary efficacy end point included stroke, systemic embolism, and cardiovascular death, and the primary analysis was by intention to treat. After 1588 patient-years of follow-up (mean 2.3±1.1 years), the primary efficacy event rates were 3.0% and 4.3% (percent per 100 patient-years) in the Watchman and warfarin groups, respectively (relative risk, 0.71; 95% confidence interval, 0.44%–1.30% per year), which met the criteria for noninferiority (probability of noninferiority >0.999). There were more primary safety events in the Watchman group (5.5% per year; 95% confidence interval, 4.2%–7.1% per year) than in the control group (3.6% per year; 95% confidence interval, 2.2%–5.3% per year; relative risk, 1.53; 95% confidence interval, 0.95–2.70). Conclusions— The “local” strategy of left atrial appendage closure is noninferior to “systemic” anticoagulation with warfarin. PROTECT AF has, for the first time, implicated the left atrial appendage in the pathogenesis of stroke in atrial fibrillation. Clinical Trial Registration:— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00129545.
Safety of Percutaneous Left Atrial Appendage Closure
Background— The Watchman Left Atrial Appendage System for Embolic Protection in Patients With AF (PROTECT AF) randomized trial compared left atrial appendage closure against warfarin in atrial fibrillation (AF) patients with CHADS 2 ≥1. Although the study met the primary efficacy end point of being noninferior to warfarin therapy for the prevention of stroke/systemic embolism/cardiovascular death, there was a significantly higher risk of complications, predominantly pericardial effusion and procedural stroke related to air embolism. Here, we report the influence of experience on the safety of percutaneous left atrial appendage closure. Methods and Results— The study cohort for this analysis included patients in the PROTECT AF trial who underwent attempted device left atrial appendage closure (n=542 patients) and those from a subsequent nonrandomized registry of patients undergoing Watchman implantation (Continued Access Protocol [CAP] Registry; n=460 patients). The safety end point included bleeding- and procedure-related events (pericardial effusion, stroke, device embolization). There was a significant decline in the rate of procedure- or device-related safety events within 7 days of the procedure across the 2 studies, with 7.7% and 3.7% of patients, respectively, experiencing events ( P =0.007), and between the first and second halves of PROTECT AF and CAP, with 10.0%, 5.5%, and 3.7% of patients, respectively, experiencing events ( P =0.006). The rate of serious pericardial effusion within 7 days of implantation, which had made up >50% of the safety events in PROTECT AF, was lower in the CAP Registry (5.0% versus 2.2%, respectively; P =0.019). There was a similar experience-related improvement in procedure-related stroke (0.9% versus 0%, respectively; P =0.039). Finally, the functional impact of these safety events, as defined by significant disability or death, was statistically superior in the Watchman group compared with the warfarin group in PROTECT AF. This remained true whether significance was defined as a change in the modified Rankin score of ≥1, ≥2, or ≥3 (1.8 versus 4.3 events per 100 patient-years; relative risk, 0.43; 95% confidence interval, 0.24 to 0.82; 1.5 versus 3.7 events per 100 patient-years; relative risk, 0.41; 95% confidence interval, 0.22 to 0.82; and 1.4 versus 3.3 events per 100 patient-years; relative risk, 0.43; 95% confidence interval, 0.22 to 0.88, respectively). Conclusion— As with all interventional procedures, there is a significant improvement in the safety of Watchman left atrial appendage closure with increased operator experience. Clinical Trial Registration— URL: http://clinicaltrials.gov . Unique identifier: NCT00129545.