Back to Authors

Parisi, Alessio

0000-0002-9323-8012

Mayo Clinic

Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), 2400 Mol, Belgium.

Citations 23

Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode
Liang, Xiaoying , Liu, Chunbo , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M. , Parisi, Alessio , Shrestha, Deepak K. , Yaddanpudi, Sridhar, Beltran, Chris , Yaddanapudi, Sridhar , Furutani, Keith M. , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M , Parisi, Alessio , Beltran, Chris J , Liang, Xiaoying , Yaddanapudi, Sridhar , Li, Heng

Physics in Medicine & Biology | July 25, 2022 | Volume: 67 | Issue: 17 | Pages: 175001

10.1088/1361-6560/ac8410 Get It

Abstract Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.
On the calculation of the relative biological effectiveness of ion radiation therapy using a biological weighting function, the microdosimetric kinetic model (MKM) and subsequent corrections (non-Poisson MKM and modified MKM)
Parisi, Alessio , Furutani, Keith M. , Beltran, Chris , Beltran, Chris J , Parisi, Alessio , Furutani, Keith M

Physics in Medicine & Biology | April 27, 2022 | Volume: 67 | Issue: 9 | Pages: 095014

10.1088/1361-6560/ac5fdf Get It

Abstract Objective . To investigate similarities and differences in the formalism, processing, and the results of relative biological effectiveness (RBE) calculations with a biological weighting function (BWF), the microdosimetric kinetic model (MKM) and subsequent modifications (non-Poisson MKM, modified MKM). This includes: (a) the extension of the V79-RBE 10% BWF to model the RBE for other clonogenic survival levels; (b) a novel implementation of MKMs as weighting functions; (c) a benchmark against Chinese Hamster lung fibroblast (V79) in vitro data; (d) a study on the effect of pre- or post- processing the average biophysical quantities used for the RBE calculations; (e) a possible modification of the modified MKM parameters to improve the model accuracy at high linear energy transfer (LET). Methodology . Lineal energy spectra were simulated for two spherical targets (diameter = 0.464 or 1.0 μ m) using PHITS for 1 H, 4 He, 12 C, 20 Ne, 40 Ar, 56 Fe and 132 Xe ions. The results of the in silico calculations were compared with published in vitro data. Main results . All models appear to underestimate the RBE α of hydrogen ions. All MKMs generally overestimate the RBE 50% , RBE 10% and RBE 1% for ions with an LET greater than ∼200 keV μ m −1 . This overestimation is greater for small surviving fractions and is likely due to the assumption of a radiation-independent quadratic term of clonogenic survival ( ß ). The overall RBE trends seem to be best described by the novel ‘post-processing average’ implementation of the non-Poisson MKM. In case of calculations with the non-Poisson MKM, pre- or post- processing the average biophysical quantities affects the computed RBE values significantly. Significance . This study presents a systematic analysis of the formalism and results of widely used microdosimetric models of clonogenic survival for ions relevant for cancer particle therapy and space radiation protection. Points for improvements were highlighted and will contribute to the development of upgraded biophysical models.
Track-structure modes in particle and heavy ion transport code system (PHITS): application to radiobiological research
Matsuya, Yusuke , Kai, Takeshi , Sato, Tatsuhiko , Ogawa, Tatsuhiko , Yoshii, Yuji, Parisi, Alessio , Liamsuwan, Thiansin , Parisi, Alessio , Hirata, Yuho

International Journal of Radiation Biology | December 21, 2021 | Volume: 98 | Issue: 2 | Pages: 148-157

10.1080/09553002.2022.2013572 Get It