Abstract Background and study aims Optical coherence tomography (OCT) is a new technology available for evaluation of indeterminate biliary strictures. It allows under-the-surface visualization and preliminary studies have confirmed standardized characteristics associated with malignancy. The aim of this study is to evaluate the first interobserver agreement in identifying previously agreed upon OCT criteria and diagnosing of malignant versus benign disease. Patients and methods Fourteen endoscopists were asked to review an atlas of reference clips and images of eight criteria derived from expert consensus A total of 35 de-identified video clips were then evaluated for presence of the eight criteria and for final diagnosis of malignant versus benign using the atlas as reference Intraclass correlation (ICC) analysis was done to evaluate interrater agreement. Results Clips of 23 malignant lesions and 12 benign lesions were scored. Excellent interobserver agreement was seen with dilated hypo-reflective structures (0.85) and layering effacement (0.89); hyper-glandular mucosa (0.76), intact layering (0.81), and onion-skin layering (0.77); fair agreement was seen with scalloping (0.58), and thickened epithelium (0.4); poor agreement was seen with hyper-reflective surface (0.36). The diagnostic ICC for both neoplastic (0.8) and non-neoplastic (0.8) was excellent interobserver agreement. The overall diagnostic accuracy was 51 %, ranging from 43 % to 60 %. Conclusions Biliary OCT is a promising new modality for evaluation of indeterminate biliary strictures. Interobserver agreement ranged from fair to almost perfect on eight previously identified criteria. Interobserver agreement for malignancy diagnosis was substantial (0.8). Further studies are needed to validate this data.
S984 Pooled Diagnostic Performance of Artificial Intelligence in Endoscopic Ultrasound Image Analysis of Solid Pancreatic Masses: A Descriptive Quantitative Review
Abstract Background and study aims Despite the clinical efficacy of peroral endoscopic myotomy (POEM), postoperative symptomatic gastroesophageal reflux disease (GERD) remains a major concern. While it is known that length of the gastric myotomy affects postoperative GERD, the clinical relevance of variation in esophageal myotomy length is not well known. We performed a systematic review and meta-analysis of studies comparing outcomes of short versus standard myotomy length in patients with achalasia. Patients and methods We searched multiple databases from inception through November 2020 to identify studies that reported on outcomes of achalasia patients who underwent short compared with standard esophageal myotomy. Meta-analysis was performed to determine pooled odds ratio (OR) of clinical success, GERD outcomes, and adverse events with the two techniques. Results 5 studies with 474 patients were included in the final analysis (short myotomy group 214, standard myotomy group 260). There was no difference in clinical success (OR 1.17, 95 % confidence interval [CI] 0.54–2.52; I2 0 %; P = 0.69), postoperative symptomatic GERD (OR 0.87, 95 %CI 0.44–1.74; I2 29 %; P = 0.70), and overall adverse events (OR 0.52, 95 %CI 0.19–1.38; I2 40 %; P = 0.19), between the two groups. Incidence of postoperative erosive esophagitis as determined by endoscopy was lower in the short myotomy group (OR 0.50, 95 %CI 0.24–1.03; I2 0 %; P = 0.06). Conclusion Our analysis showed that performing POEM with short esophageal myotomy in achalasia was as safe and effective as standard myotomy, with lower incidence of postoperative erosive esophagitis.
Clinical efficacy and safety of magnetic sphincter augmentation (MSA) and transoral incisionless fundoplication (TIF2) in refractory gastroesophageal reflux disease (GERD): a systematic review and meta-analysis
Abstract Background and study aims Proton pump inhibitors (PPI) are effective medical therapy options for gastro-esophageal reflux disease (GERD). However, 20 % to 40 % of patients report symptoms despite taking daily PPI. Transoral incisionless fundoplication (TIF2) and magnetic sphincter augmentation (MSA) are less invasive options for the treatment of refractory GERD and are increasingly gaining popularity. Methods We conducted a comprehensive search of several databases to identify relevant studies. Our primary aim was to compare the efficacy of both interventions reported as improvement in Gastroesophageal Reflux Disease-Health Related Quality of Life (GERD-HRQL) score, overall patient satisfaction, improvement in post-procedure regurgitation, and fraction of patients completely off PPI therapy at follow up. Results Twenty-four studies with 1942 patients were included in the final analysis. Both MSA and TIF2 had comparable technical success and clinical success based on improvement in GERD-HRQL scores i. e. 98.8 % (CI 95.6,99.7) vs 98.5 % (CI 95.7,99.5) and 80.4 % (CI 66,89.6) vs 77.7 % (CI 64.1,87.2), respectively. A significantly greater proportion of patients reported improvement in regurgitation, i. e. 91.1 % (CI 83.8,95.3) vs 73.1 % (CI 62.5,81.7) and were able to completely discontinue PPI therapy with MSA compared to TIF2 i. e. 91.3 % (CI 81.5,96.2) vs 63.8 % (CI 51.6,74.4). Patients’ BMI and presence of a hiatal hernia did not have any effect on procedural outcomes. Conclusion Both procedures performed at par when comparing clinical success in terms of improvement in GERD-HRQL scores. In terms of overall patient satisfaction, post procedure regurgitation and cumulative number of patients off PPI therapy, MSA outperforms TIF2.
Intracystic Glucose Levels in Differentiating Mucinous From Nonmucinous Pancreatic Cysts
Background: Mucinous pancreatic cysts are well reported to transform into pancreatic adenocarcinoma, whereas nonmucinous cysts are mostly benign with low risk for malignant transformation. Nonsurgical methods of differentiating mucinous and nonmucinous pancreatic cysts are challenging and entail a multi investigational approach. Low intracystic glucose levels have been evaluated in multiple studies for its accuracy in differentiating mucinous from nonmucinous cysts of the pancreas. Methods: Multiple databases were searched and studies that reported on the utility of intracystic glucose levels in diagnosing mucinous pancreatic cysts were analyzed. Meta-analysis was conducted using the random-effects model, heterogeneity was assessed by I 2%, and pooled diagnostic test accuracy values were calculated. Results: Seven studies were included in the analysis from an initial total of 375 citations. The pooled sensitivity of low glucose in differentiating mucinous pancreatic cyst was 90.5% [95% confidence interval (CI): 88.1-92.5; I 2=0%] and the pooled specificity was 88% (95% CI: 80.8-92.7; I 2=79%). The sensitivity at a glucose cut-off of 50 was 90.1% (95% CI: 87.2-92.5; I 2=0%) and the specificity was 85.3% (95% CI: 76.8-91.1; I 2=76%). The sensitivity of glucose levels in pancreatic cyst fluid taken by endoscopic ultrasound guided fine-needle aspiration was 90.8% (95% CI: 87.9-93.1; I 2=0%) and the specificity was 90.5% (95% CI: 81.7-95.3; I 2=83%). The sensitivity of point-of-care glucometers was 89.5% (95% CI: 87.9-93.1; I 2=0%) and specificity was 83.9% (95% CI: 68.5-92.6; I 2=43%). Conclusions: Low glucose level at a cut-off of 50 mg/dL on fluid samples collected by endoscopic ultrasound guided fine-needle aspiration and analyzed by point-of-care glucometer achieves excellent diagnostic accuracy in differentiating mucinous pancreatic cysts.
EUS-guided gastroenterostomy versus enteral stenting for gastric outlet obstruction: Systematic review and meta-analysis
Abtract Background and study aims Endoscopic and surgical techniques have been utilized for palliation of gastric outlet obstruction (GOO). Enteral stenting (ES) is an established technique with high clinical success and low morbidity rate. Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is a novel approach that aims to provide sustained palliation of GOO. We conducted a comprehensive review and meta-analysis to evaluate the effectiveness in terms of clinical and technical success, as well as the safety profile of EUS-GE and ES. Methods We searched multiple databases from inception through July 2020 to identify studies that reported on safety and effectiveness of EUS-GE in comparison to ES. Pooled rates of technical success, clinical success, and adverse events (AEs) were calculated. Study heterogeneity was assessed using I2% and 95 % confidence interval. Results Five studies including 659 patients were included in our final analysis. Pooled rate of technical and clinical success for EUS-GE was 95.2 % (CI 87.2-.98.3, I2 = 42) and 93.3 % (CI 84.4–97.3, I2 = 59) while for ES it was 96.9 % (CI 90.9–99, I2 = 64) and 85.6 % (CI 73–92.9, I2 = 85), respectively. Pooled rate of re-intervention was significantly lower with EUS-GE i. e. 4 % (CI 1.8–8.7, I2 = 35) compared to ES, where it was 23.6 % (CI 17.5–31, I2 = 35), p = 0.001. Pooled rates of overall and major AEs were comparable between the two techniques. Conclusion EUS-GE is comparable in terms of technical and clinical effectiveness and has a similar safety profile when compared to ES for palliation of GOO.
S0053 Comparison of EUS-Guided Conventional Smear Cytology and Liquid Based Cytology in Pancreatic Lesions: A Systematic Review and Meta-Analysis
Abstract Background and study aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (EUS-FNA) has limitations of inadequate sampling and false-negative results for malignancy. It has been performed using conventional smear (CS) cytology with rapid on-site evaluation (ROSE) with reasonable diagnostic accuracy. An alternative to ROSE is liquid-based cytology (LBC). Commonly used LBC techniques include precipitation-based (SurePath™) and filtration-based (ThinPrep®, CellPrep®). Data regarding the diagnostic efficacy of LBC compared with CS are limited. Methods Multiple databases were searched through March 2020 to identify studies reporting diagnostic yield of EUS-guided CS and LBC in pancreatic lesions. Pooled diagnostic odds and rates of performance for the cytologic diagnoses of benign, suspicious, and malignant lesions were calculated. Diagnostic efficacy was evaluated by pooled rates of accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results Nine studies with a total of 1308 patients were included in our final analysis. Pooled diagnostic odds of CS cytology were 1.69 (CI 1.02–2.79) and 0.39 (CI 0.19–0.8) for malignant lesions when compared to filtration-based and precipitation-based LBC techniques, respectively. For CS, precipitation-based and filtration-based LBC, pooled diagnostic accuracy was 79.7 %, 85.2 %, 77.3 %, sensitivity was 79.2 %, 83.6 %, 68.3 %, and specificity was 99.4 %, 99.5 %, 99.5 %, respectively. Conclusions The precipitation-based LBC technique (SurePath™) had superior diagnostic odds for malignant pancreatic lesions compared with CS cytology in the absence of ROSE. It showed superior accuracy and sensitivity, but comparable specificity and PPV. Diagnostic odds of CS cytology in the absence of ROSE were superior to the filtration-based LBC technique (ThinPrep®, Cellprep®) for diagnosing malignant pancreatic lesions.
Efficacy and safety of endoscopic ultrasound-guided pancreatic duct drainage (EUS-PDD): A systematic review and meta-analysis of 714 patients
Abstract Background and study aims Endoscopic ultrasound guided pancreatic duct drainage (EUS-PDD) is a minimal-invasive therapeutic option to surgery and in patients with failed endoscopic retrograde pancreatography (ERP). The aim of this review was to quantitatively appraise the clinical outcomes of EUS-PDD by meta-analysis methods. Methods We searched multiple databases from inception through March 2020 to identify studies that reported on EUS-PDD. Pooled rates of technical success, successful drainage of pancreatic duct, clinical success, and adverse events were calculated. Study heterogeneity was assessed using I2% and 95 % prediction interval. Results A total of 22 studies (714 patients) were included. The pooled rate of technical success in EUS-PDD was 84.8 % (95 % CI 79.1–89.2). The pooled rate of successful PD drained by EUS-PDD was 77.5 % (95 % CI 63.1–87.4). The pooled rate of clinical success of EUS-PDD was 89.2 % (95 % CI 82.1–93.7). The pooled rate of all adverse events was 18.1 % (95 % CI 14.2–22.9). On sub-group analysis, the pooled technical success and clinical success of EUS-PDD from Japanese data were considerably superior (91.2 %, 83–95.6 & 92.5 %, 83.9–96.7, respectively). The pooled rate of post EUS-PDD acute pancreatitis was 6.6 % (95 % CI 4.5–9.4), bleeding was 4.1 % (95 % CI 2.7–6.2), perforation and/or pneumoperitoneum was 3.1 % (95 % CI 1.9–5), pancreatic leak and/or pancreatic fluid collection was 2.3 % (95 % CI 1.4–4), and infection was 2.8 % (95 % CI 1.7–4.6). Conclusion EUS-PDD demonstrates high technical success and clinical success rates with acceptable adverse events. Technical success was especially high for anastomotic strictures.