Abstract Background and study aims Despite the clinical efficacy of peroral endoscopic myotomy (POEM), postoperative symptomatic gastroesophageal reflux disease (GERD) remains a major concern. While it is known that length of the gastric myotomy affects postoperative GERD, the clinical relevance of variation in esophageal myotomy length is not well known. We performed a systematic review and meta-analysis of studies comparing outcomes of short versus standard myotomy length in patients with achalasia. Patients and methods We searched multiple databases from inception through November 2020 to identify studies that reported on outcomes of achalasia patients who underwent short compared with standard esophageal myotomy. Meta-analysis was performed to determine pooled odds ratio (OR) of clinical success, GERD outcomes, and adverse events with the two techniques. Results 5 studies with 474 patients were included in the final analysis (short myotomy group 214, standard myotomy group 260). There was no difference in clinical success (OR 1.17, 95 % confidence interval [CI] 0.54–2.52; I2 0 %; P = 0.69), postoperative symptomatic GERD (OR 0.87, 95 %CI 0.44–1.74; I2 29 %; P = 0.70), and overall adverse events (OR 0.52, 95 %CI 0.19–1.38; I2 40 %; P = 0.19), between the two groups. Incidence of postoperative erosive esophagitis as determined by endoscopy was lower in the short myotomy group (OR 0.50, 95 %CI 0.24–1.03; I2 0 %; P = 0.06). Conclusion Our analysis showed that performing POEM with short esophageal myotomy in achalasia was as safe and effective as standard myotomy, with lower incidence of postoperative erosive esophagitis.
Clinical efficacy and safety of magnetic sphincter augmentation (MSA) and transoral incisionless fundoplication (TIF2) in refractory gastroesophageal reflux disease (GERD): a systematic review and meta-analysis
Abstract Background and study aims Proton pump inhibitors (PPI) are effective medical therapy options for gastro-esophageal reflux disease (GERD). However, 20 % to 40 % of patients report symptoms despite taking daily PPI. Transoral incisionless fundoplication (TIF2) and magnetic sphincter augmentation (MSA) are less invasive options for the treatment of refractory GERD and are increasingly gaining popularity. Methods We conducted a comprehensive search of several databases to identify relevant studies. Our primary aim was to compare the efficacy of both interventions reported as improvement in Gastroesophageal Reflux Disease-Health Related Quality of Life (GERD-HRQL) score, overall patient satisfaction, improvement in post-procedure regurgitation, and fraction of patients completely off PPI therapy at follow up. Results Twenty-four studies with 1942 patients were included in the final analysis. Both MSA and TIF2 had comparable technical success and clinical success based on improvement in GERD-HRQL scores i. e. 98.8 % (CI 95.6,99.7) vs 98.5 % (CI 95.7,99.5) and 80.4 % (CI 66,89.6) vs 77.7 % (CI 64.1,87.2), respectively. A significantly greater proportion of patients reported improvement in regurgitation, i. e. 91.1 % (CI 83.8,95.3) vs 73.1 % (CI 62.5,81.7) and were able to completely discontinue PPI therapy with MSA compared to TIF2 i. e. 91.3 % (CI 81.5,96.2) vs 63.8 % (CI 51.6,74.4). Patients’ BMI and presence of a hiatal hernia did not have any effect on procedural outcomes. Conclusion Both procedures performed at par when comparing clinical success in terms of improvement in GERD-HRQL scores. In terms of overall patient satisfaction, post procedure regurgitation and cumulative number of patients off PPI therapy, MSA outperforms TIF2.
Intracystic Glucose Levels in Differentiating Mucinous From Nonmucinous Pancreatic Cysts
Background: Mucinous pancreatic cysts are well reported to transform into pancreatic adenocarcinoma, whereas nonmucinous cysts are mostly benign with low risk for malignant transformation. Nonsurgical methods of differentiating mucinous and nonmucinous pancreatic cysts are challenging and entail a multi investigational approach. Low intracystic glucose levels have been evaluated in multiple studies for its accuracy in differentiating mucinous from nonmucinous cysts of the pancreas. Methods: Multiple databases were searched and studies that reported on the utility of intracystic glucose levels in diagnosing mucinous pancreatic cysts were analyzed. Meta-analysis was conducted using the random-effects model, heterogeneity was assessed by I 2%, and pooled diagnostic test accuracy values were calculated. Results: Seven studies were included in the analysis from an initial total of 375 citations. The pooled sensitivity of low glucose in differentiating mucinous pancreatic cyst was 90.5% [95% confidence interval (CI): 88.1-92.5; I 2=0%] and the pooled specificity was 88% (95% CI: 80.8-92.7; I 2=79%). The sensitivity at a glucose cut-off of 50 was 90.1% (95% CI: 87.2-92.5; I 2=0%) and the specificity was 85.3% (95% CI: 76.8-91.1; I 2=76%). The sensitivity of glucose levels in pancreatic cyst fluid taken by endoscopic ultrasound guided fine-needle aspiration was 90.8% (95% CI: 87.9-93.1; I 2=0%) and the specificity was 90.5% (95% CI: 81.7-95.3; I 2=83%). The sensitivity of point-of-care glucometers was 89.5% (95% CI: 87.9-93.1; I 2=0%) and specificity was 83.9% (95% CI: 68.5-92.6; I 2=43%). Conclusions: Low glucose level at a cut-off of 50 mg/dL on fluid samples collected by endoscopic ultrasound guided fine-needle aspiration and analyzed by point-of-care glucometer achieves excellent diagnostic accuracy in differentiating mucinous pancreatic cysts.
EUS-guided gastroenterostomy versus enteral stenting for gastric outlet obstruction: Systematic review and meta-analysis
Abtract Background and study aims Endoscopic and surgical techniques have been utilized for palliation of gastric outlet obstruction (GOO). Enteral stenting (ES) is an established technique with high clinical success and low morbidity rate. Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is a novel approach that aims to provide sustained palliation of GOO. We conducted a comprehensive review and meta-analysis to evaluate the effectiveness in terms of clinical and technical success, as well as the safety profile of EUS-GE and ES. Methods We searched multiple databases from inception through July 2020 to identify studies that reported on safety and effectiveness of EUS-GE in comparison to ES. Pooled rates of technical success, clinical success, and adverse events (AEs) were calculated. Study heterogeneity was assessed using I2% and 95 % confidence interval. Results Five studies including 659 patients were included in our final analysis. Pooled rate of technical and clinical success for EUS-GE was 95.2 % (CI 87.2-.98.3, I2 = 42) and 93.3 % (CI 84.4–97.3, I2 = 59) while for ES it was 96.9 % (CI 90.9–99, I2 = 64) and 85.6 % (CI 73–92.9, I2 = 85), respectively. Pooled rate of re-intervention was significantly lower with EUS-GE i. e. 4 % (CI 1.8–8.7, I2 = 35) compared to ES, where it was 23.6 % (CI 17.5–31, I2 = 35), p = 0.001. Pooled rates of overall and major AEs were comparable between the two techniques. Conclusion EUS-GE is comparable in terms of technical and clinical effectiveness and has a similar safety profile when compared to ES for palliation of GOO.