Back to Authors

Moyer, Thomas P.

https://orcid.org/0000-0002-2110-2845

Mayo Clinic

Drug Laboratory, Department of Laboratory Medicine & Pathology,

Citations 21

Simultaneous Analysis of Nicotine, Nicotine Metabolites, and Tobacco Alkaloids in Serum or Urine by Tandem Mass Spectrometry, with Clinically Relevant Metabolic Profiles
Moyer, Thomas P. , Charlson, Joel R., Enger, Robert J, Dale, Lowell C., Ebbert, Jon O. , Schroeder, Darrell R. , Hurt, R. Douglas , Schroeder, Darrell , Enger, Robert J

Clinical Chemistry | January 24, 2020 | Volume: 48 | Issue: 9 | Pages: 1460-1471

10.1093/clinchem/48.9.1460 Get It

Abstract Background: Assessment of nicotine metabolism and disposition has become an integral part of nicotine dependency treatment programs. Serum nicotine concentrations or urine cotinine concentrations can be used to guide nicotine patch dose to achieve biological concentrations adequate to provide the patient with immediate relief from nicotine withdrawal symptoms, an important factor in nicotine withdrawal success. Absence of nicotine metabolites and anabasine can be used to document abstinence from tobacco products, an indicator of treatment success. Methods: The procedure was designed to quantify nicotine, cotinine, trans-3′-hydroxycotinine, anabasine, and nornicotine in human serum or urine. The technique required simple extraction of the sample with quantification by HPLC–tandem mass spectrometry. Results: The procedure for simultaneous analysis of nicotine, its metabolites, and tobacco alkaloids simultaneously quantified five different analytes. Test limit of quantification, linearity, imprecision, and accuracy were adequate for clinical evaluation of patients undergoing treatment for tobacco dependency. The test readily distinguished individuals who had no exposure to tobacco products from individuals who were either passively exposed or were abstinent past-tobacco users from those who were actively using a tobacco or nicotine product. Conclusions: Nicotine, cotinine, trans-3′-hydroxycotinine, nornicotine, and anabasine can be simultaneously and accurately quantified in either serum or urine by HPLC–tandem mass spectrometry with imprecision <10% at physiologic concentrations and limits of quantification ranging from 0.5 to 5 μg/L. Knowledge of serum or urine concentrations of these analytes can be used to guide nicotine replacement therapy or to assess tobacco abstinence in nicotine dependency treatment. These measurements are now an integral part of the clinical treatment and management of patients who wish to overcome tobacco dependence.
Brush with Death: A Social History of Lead Poisoning. Christian Warren. Baltimore, MD: The Johns Hopkins University Press, 2000, 370 pp., $45.00, hardcover. ISBN 0-8018-6289-2.
Moyer, Thomas P.

Clinical Chemistry | January 24, 2020 | Volume: 48 | Issue: 1 | Pages: 210-210

10.1093/clinchem/48.1.210 Get It

Filter Paper Lead Testing
Moyer, Thomas P. , Nixon, David N, Ash, K O

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 12 | Pages: 2055-2056

10.1093/clinchem/45.12.2055 Get It

Drug Monitoring of Antiretroviral Therapy for HIV-1 Infection: Method Validation and Results of a Pilot Study
Moyer, Thomas P. , Temesgen, Zelalem , Enger, Robert, Estes, Lynn L., Charlson, Joel, Oliver, Lawrence K., Wright, Alan J. , Enger, Robert, Charlson, Joel R., Wright, Alan

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 9 | Pages: 1465-1476

10.1093/clinchem/45.9.1465 Get It

Abstract Background: Antiretroviral therapy for HIV-1 infection has become increasingly complex. The availability of new and potent drugs and progress in understanding the pathogenesis of HIV-1 infection have led to the establishment of new treatment paradigms. The varying dosing regimens, associated toxicities, and the potential for drug-drug and food-drug interactions further complicate treatment. This complexity contributes to patient nonadherence. Because clinicians have no tools to monitor adherence or drug-drug interactions and because response requires that therapy exceed the known inhibiting concentration, serum monitoring of antiretroviral therapy may play a role in improving treatment of HIV-1 infection. We report methods to quantify serum concentrations of antiretroviral drugs used to treat HIV-1 infection, precision and interference studies of these methods, and results observed in a pilot evaluation of blood serum concentrations from 12 human subjects. Methods: HPLC offers adequate sensitivity to measure peak or trough serum concentrations of delavirdine, lamivudine, nevirapine, indinavir, nelfinavir, ritonavir, and saquinavir and peak serum concentrations of stavudine, zidovudine, and didanosine with reasonable precision. Results: Peak indinavir serum concentrations in most patients were in the range of 1–10 mg/L, and trough concentrations were in the range of 0.1–0.5 mg/L. Peak stavudine concentrations were in the range of 0.3–1.3 mg/L, and trough concentrations were in the range of 0.1–0.5 mg/L. Peak zidovudine concentrations were in the range of 0.1–1.1 mg/L. Conclusions: Because this was a blood serum concentration-seeking pilot study to evaluate analytic performance, we do not report on the correlation of drug response to blood concentration. However, the concentrations observed in patients are generally consistent with blood concentrations reported from studies of monotherapy.
Supporting pharmaceutical studies for FDA submissions: diversifying the drug monitoring laboratory
Moyer, Thomas P. , Oliver, Lawrence K.

Clinical Chemistry | January 23, 2020 | Volume: 44 | Issue: 2 | Pages: 433-436

10.1093/clinchem/44.2.433 Get It

Abstract Well-founded pharmacokinetic information is one of the cornerstones of a New Drug Application (NDA) to the Food and Drug Administration (FDA) required to introduce a new drug or a generic equivalent (ANDA) to the marketplace. The service that laboratories engaged in therapeutic drug monitoring provide to support clinical activities is also needed by the pharmaceutical industry during the evaluation and introduction of drugs to the marketplace. In considering this alternative service activity, one must be aware of and compliant with rules established by the FDA for performance of such studies. As specified in CFR 21, Parts 58, 211, and 320, good clinical and laboratory practice indicates that the laboratory should employ a Lab Study Director, who is responsible for the validation of all procedures implemented to support a study protocol, ensures that the laboratory carries out the study following these defined procedures, and personally reviews the results of all testing. The laboratory must validate each procedure by demonstrating and documenting that the procedure does what it is designed to do while meeting the analytical performance specifications required by the study. Laboratory records of all activities must be maintained and available for inspection by the FDA on request. The FDA has authority over all activities related to NDA and ANDA submissions and can bring criminal charges if results of a study are changed because a laboratory deviates from standard procedure. Competent drug monitoring laboratories are fully capable of participating in clinical trials testing activities. Laboratory staff should be fully versed in the FDA rules governing these activities, validate all procedures, and establish systems to verify the procedures are carried out as specified.
Arsenic Analysis II: Rapid Separation and Quantification of Inorganic Arsenic Plus Metabolites and Arsenobetaine from Urine
Nixon, David E., Moyer, Thomas P.

Clinical Chemistry | January 13, 2020 | Volume: 38 | Issue: 12 | Pages: 2479-2483

10.1093/clinchem/38.12.2479 Get It

Abstract We describe the rapid separation of inorganic arsenic plus metabolites from arsenobetaine or seafood arsenic in urine. Traditional, high-pressure liquid chromatography is replaced by disposable silica-based cation-exchange cartridges for this separation. Both fractions are quickly separated and collected for analysis by atomic absorption spectrophotometry. Analytical recovery of both fractions is > or = 95%, with an overall precision (CV) ranging from 1.6% to 6.4%. Using this method, we correctly identified the sources of arsenic exposure, whether of inorganic or seafood origin, in 11 urine specimens supplied by the Centre de Toxicologie du Quebec.
Total arsenic in urine: palladium-persulfate vs nickel as a matrix modifier for graphite furnace atomic absorption spectrophotometry
Nixon, David E., Mussmann, G V, Eckdahl, Steven J., Moyer, Thomas P.

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 9 | Pages: 1575-1579

10.1093/clinchem/37.9.1575 Get It

Abstract We evaluated the effectiveness of nickel and palladium with or without added potassium persulfate as matrix modifiers for the determination of total arsenic in urine. Complete recovery of pure aqueous solutions of As(III), As(V), cacodylic acid (DMA), monomethylarsinic acid (MMA), and o-arsanilic acid was attained by using both nickel and palladium modifiers. Combined arsenobetaine and arsenocholine (so-called fish arsenic), extracted from a certified control material of dogfish muscle (DORM-1), were completely recovered with Pd-S2O8 matrix modification, but not with nickel. Excellent agreement with target values for arsenic in urines from the Centre de Toxicologie du Quebec, supplied by the Interlaboratory Comparison Program, was attained irrespective of the arsenic source when we used Pd-S2O8 as the matrix modifier.
Blood-collection device for trace and ultra-trace metal specimens evaluated
Moyer, Thomas P. , Mussmann, G V, Nixon, David E.

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 5 | Pages: 709-714

10.1093/clinchem/37.5.709 Get It

Abstract We evaluated the evacuated phlebotomy tube designed specifically for trace metal analysis by Sherwood Medical Co. Pools of human serum containing known concentrations of aluminum, arsenic, calcium, cadmium, copper, chromium, iron, lead, magnesium, manganese, mercury, selenium, and zinc were exposed to the tube and rubber stopper for defined periods ranging from 5 min to 24 h. Analysis for each element was performed in a randomized fashion under rigidly controlled conditions by use of standard electrothermal atomization atomic absorption spectroscopy, inductively coupled plasma atomic emission spectroscopy, and cold vapor atomic absorption spectrometry. In addition, for comparative purposes, we collected blood samples from normal volunteers by use of ultra-clean polystyrene phlebotomy syringes as well as standard evacuated phlebotomy tubes. We conclude that, except for lead, there was no significant contribution of any trace element studied from the evaluated tube and stopper to the serum. Because whole blood is the usual specimen for lead testing, the observation of a trace amount of lead in this tube designed for serum collection is trivial.
Evaluation of Abbott TDx monoclonal assay of cyclosporine in whole blood
Moyer, Thomas P. , Winkels, Julie, Krom, Ruud, Wiesner, Russell H.

Clinical Chemistry | January 13, 2020 | Volume: 37 | Issue: 6 | Pages: 1120-1121

10.1093/clinchem/37.6.1120a Get It

Essential and toxic element concentrations in fresh and formalin-fixed human autopsy tissues
Bush, V., Moyer, Thomas P. , Batts, Kenneth P. , Parisi, Joseph E., Bush, V J

Clinical Chemistry | January 11, 2020 | Volume: 41 | Issue: 2 | Pages: 284-294

10.1093/clinchem/41.2.284 Get It

Abstract The concentrations of five essential elements and six potentially toxic elements were determined in seven organs collected at autopsy from 30 human subjects. Elemental analyses were carried out by graphite furnace atomic absorption spectroscopy, and inductively coupled plasma emission spectroscopy, and inductively coupled plasma mass spectroscopy, and concentrations in fresh and formalin-fixed tissues were compared. Formalin-fixation long-term storage has little effect on most element concentrations in tissue, except for Al and Mn, which changed with prolonged storage in formalin. The kidney and liver contained the greatest concentrations of toxic elements compared with other organs, whereas the essential elements were uniformly distributed among all organs. There was no more than a 10-fold difference in the tissue concentration of the elements studied among the organs, except for the concentration of Fe in liver, and Ca and Mg in bone. We also demonstrate that these elements are homogeneously distributed in tissues.