Drug Laboratory, Department of Laboratory Medicine & Pathology,
Citations 4
Simultaneous Analysis of Nicotine, Nicotine Metabolites, and Tobacco Alkaloids in Serum or Urine by Tandem Mass Spectrometry, with Clinically Relevant Metabolic Profiles
Abstract Background: Assessment of nicotine metabolism and disposition has become an integral part of nicotine dependency treatment programs. Serum nicotine concentrations or urine cotinine concentrations can be used to guide nicotine patch dose to achieve biological concentrations adequate to provide the patient with immediate relief from nicotine withdrawal symptoms, an important factor in nicotine withdrawal success. Absence of nicotine metabolites and anabasine can be used to document abstinence from tobacco products, an indicator of treatment success. Methods: The procedure was designed to quantify nicotine, cotinine, trans-3′-hydroxycotinine, anabasine, and nornicotine in human serum or urine. The technique required simple extraction of the sample with quantification by HPLC–tandem mass spectrometry. Results: The procedure for simultaneous analysis of nicotine, its metabolites, and tobacco alkaloids simultaneously quantified five different analytes. Test limit of quantification, linearity, imprecision, and accuracy were adequate for clinical evaluation of patients undergoing treatment for tobacco dependency. The test readily distinguished individuals who had no exposure to tobacco products from individuals who were either passively exposed or were abstinent past-tobacco users from those who were actively using a tobacco or nicotine product. Conclusions: Nicotine, cotinine, trans-3′-hydroxycotinine, nornicotine, and anabasine can be simultaneously and accurately quantified in either serum or urine by HPLC–tandem mass spectrometry with imprecision <10% at physiologic concentrations and limits of quantification ranging from 0.5 to 5 μg/L. Knowledge of serum or urine concentrations of these analytes can be used to guide nicotine replacement therapy or to assess tobacco abstinence in nicotine dependency treatment. These measurements are now an integral part of the clinical treatment and management of patients who wish to overcome tobacco dependence.
Drug Monitoring of Antiretroviral Therapy for HIV-1 Infection: Method Validation and Results of a Pilot Study
Abstract Background: Antiretroviral therapy for HIV-1 infection has become increasingly complex. The availability of new and potent drugs and progress in understanding the pathogenesis of HIV-1 infection have led to the establishment of new treatment paradigms. The varying dosing regimens, associated toxicities, and the potential for drug-drug and food-drug interactions further complicate treatment. This complexity contributes to patient nonadherence. Because clinicians have no tools to monitor adherence or drug-drug interactions and because response requires that therapy exceed the known inhibiting concentration, serum monitoring of antiretroviral therapy may play a role in improving treatment of HIV-1 infection. We report methods to quantify serum concentrations of antiretroviral drugs used to treat HIV-1 infection, precision and interference studies of these methods, and results observed in a pilot evaluation of blood serum concentrations from 12 human subjects. Methods: HPLC offers adequate sensitivity to measure peak or trough serum concentrations of delavirdine, lamivudine, nevirapine, indinavir, nelfinavir, ritonavir, and saquinavir and peak serum concentrations of stavudine, zidovudine, and didanosine with reasonable precision. Results: Peak indinavir serum concentrations in most patients were in the range of 1–10 mg/L, and trough concentrations were in the range of 0.1–0.5 mg/L. Peak stavudine concentrations were in the range of 0.3–1.3 mg/L, and trough concentrations were in the range of 0.1–0.5 mg/L. Peak zidovudine concentrations were in the range of 0.1–1.1 mg/L. Conclusions: Because this was a blood serum concentration-seeking pilot study to evaluate analytic performance, we do not report on the correlation of drug response to blood concentration. However, the concentrations observed in patients are generally consistent with blood concentrations reported from studies of monotherapy.
Automated HPLC assay of fluoxetine and norfluoxetine in serum
Abstract This automated assay determines the concentration of the antidepressant fluoxetine (Prozac) and its active metabolite norfluoxetine in serum by reversed-phase HPLC with spectrophotometric detection. Extraction, injection, and quantification are performed by the Gilson Aspec automated sample handler. The patient's specimen, with added protriptyline as internal standard, is extracted with solid-phase and liquid-liquid methods. Separation is conducted isocratically on a 5-microns (particle size) Supelcosil LC-8-DB reversed-phase column with a triethylamine acetate:acetonitrile mobile phase. The detection limit is 10 micrograms/L and absorbance varies linearly with concentration between 20 and 1,000 micrograms/L for both compounds. Mean recovery was 62% for fluoxetine and 70% for norfluoxetine over linear limits. Within-run and day-to-day imprecision (CV), evaluated at three concentrations (50, 200, and 500 micrograms/L), ranged from 2% to 7%. An extensive interference study of 108 drugs was conducted. Results (n = 58) by the automated method (y) correlated well with those by a manual HPLC method (x): y = 0.96x + 10.20 (r = 0.951, Sylx = 42.9) for fluoxetine, and y = 0.95x - 1.37 (r = 0.917, Sylx = 47.2) for norfluoxetine.
A Solid Phase Extraction Method for Determination of Nicotine in Serum and Urine by Isotope Dilution Gas Chromatography/Mass Spectrometry with Selected Ion Monitoring
A rapid method for measuring nicotine concentration in serum and urine is described. Deuterated nicotine is used as an internal standard. Nicotine and deuterated nicotine are extracted using a copolymeric-bonded phase silica column. The extract is analysed by gas chromatography coupled with mass spectrometry (GC/MS) operating in selected ion monitoring mode. The method has a lower limit of detection of approximately 2 μg/L and is linear to at least 2000 μg/L. Within-run percentage coefficients of variation (% CV) are < 4 in both assays over a nicotine concentration range of 10–2000 μg/L. Between-run %CV in the serum assay are 5.4, 5.2, 4.8 and 5.9, respectively, at nicotine concentrations of 10, 15, 25, and 50 μg/L. Between-run %CV in the urine assay are 5.9, 4.5, 2.7 and 5.2, respectively, at nicotine concentrations of 100, 250, 500, and 2000 μg/L. The absolute recovery of nicotine is 61±+6% (mean±SD) over the range of 10–250 μg/L. The assay has been used to measure serum nicotine concentrations and 24-h urinary excretion of nicotine to monitor the extent of replacement in subjects receiving transdermal nicotine therapy for smoking cessation.