Back to Authors

Pandey, Aditya S

0000-0003-0789-4273

Mayo Clinic

Michigan Medicine

Citations 31

A human brain test bed for research in large vessel occlusion stroke
Gebrezgiabhier, Daniel , Liu, Yang , Reddy, Adithya , Savastano, Luis E., Liu, Yang , Davis, Evan, Zheng, Yihao , Shih, Albert J. , Pandey, Aditya S , Savastano, Luis

Journal of Neurosurgery | January 22, 2021 | Volume: 135 | Issue: 4 | Pages: 1072-1080

10.3171/2020.7.jns202278 Get It

OBJECTIVE Endovascular removal of emboli causing large vessel occlusion (LVO)–related stroke utilizing suction catheter and/or stent retriever technologies or thrombectomy is a new standard of care. Despite high recanalization rates, 40% of stroke patients still experience poor neurological outcomes as many cases cannot be fully reopened after the first attempt. The development of new endovascular technologies and techniques for mechanical thrombectomy requires more sophisticated testing platforms that overcome the limitations of phantom-based simulators. The authors investigated the use of a hybrid platform for LVO stroke constructed with cadaveric human brains. METHODS A test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with cadaveric human brains, a customized hydraulic system to generate physiological flow rate and pressure, and three types of embolus analogs (elastic, stiff, and fragment-prone) engineered to match mechanically and phenotypically the emboli causing LVO strokes. LVO cases were replicated in the anterior and posterior circulation, and thrombectomy was attempted using suction catheters and/or stent retrievers. RESULTS The test bed allowed radiation-free visualization of thrombectomy for LVO stroke in real cerebrovascular anatomy and flow conditions by transmural visualization of the intraluminal elements and procedures. The authors were able to successfully replicate 105 LVO cases with 184 passes in 12 brains (51 LVO cases and 82 passes in the anterior circulation, and 54 LVO cases and 102 passes in the posterior circulation). Observed recanalization rates in this model were graded using a Recanalization in LVO (RELVO) scale analogous to other measures of recanalization outcomes in clinical use. CONCLUSIONS The human brain platform introduced and validated here enables the analysis of artery-embolus-device interaction under physiological hemodynamic conditions within the unmodified complexity of the cerebral vasculature inside the human brain.
Transarterial Embolization of a Transverse Sinus Dural Arteriovenous Fistula: 2-Dimensional Operative Video
Gomez‐Paz, Santiago , Akamatsu, Yosuke , Salem, Mohamed M. , Ogilvy, Christopher S. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael R. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Ringer, Andrew J. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Levitt, Michael R , Gomez-Paz, Santiago , Schirmer, Clemens M , Ogilvy, Christopher S , Moore, Justin M. , Thomas, Ajith J , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , White, Jonathan A.

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E41-E42

10.1093/ons/opaa370 Get It

Abstract A 40-yr-old male with no significant past medical history presented with sudden onset right-sided retro-orbital headache associated with vision loss after a session of strenuous exercise. Initial assessment with noncontrast head computed tomography at the local emergency department revealed a right sided occipital intracranial hemorrhage (ICH). On arrival the patient ad a left quadrantopsia with Glasgow Coma Scale of 15 and an ICH score of 0. A computed tomographic angiography showed a high density 6 × 9 mm vascular lesion associated with 2 tortuous vessels. Cerebral angiography revealed a right sided dural arteriovenous fistula, Cognard Type IV, with arterial feeders arising from dural branches of the right vertebral artery, the posterior division of the right middle meningeal artery and meningeal branches distal to the neuromeningeal trunk of the left ascending pharyngeal artery. 1 Four days after the ICH event the patient was treated with endovascular Onyx embolization of the fistula, through a transradial approach. Immediate angiographic assessment showed complete obliteration of the dAVF. The patient was discharged home and recovered his visual field deficit over 3 mo. The following operative video includes a discussion of the endovascular technique and treatment nuances associated with the transarterial management of a dural arteriovenous fistula. Patient consent was given prior to the procedure and consent and approval for this operative video was waived due to the retrospective nature of this manuscript and the anonymized video material.
Distal Access to Wide-Necked Aneurysms—‘Around the World’ Technique: 2-Dimensional Operative Video
Ringer, Andrew J. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael R. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Ogilvy, Christopher S. , Levitt, Michael R , Schirmer, Clemens M , Ogilvy, Christopher S , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E39-E40

10.1093/ons/opaa369 Get It

Abstract Wide-necked aneurysms often pose challenges for distal access to the distal vasculature. This 64-yr-old woman without neurological deficits presented with atypical headaches of gradual onset. MRI revealed a large, symptomatic, unruptured carotid terminus aneurysm incorporating the origin of both the middle (MCA) and anterior cerebral arteries (ACA). Its wide neck created significant risks to coil prolapse and parent vessel compromise, risking stroke. With other options of higher risks, we recommended an around-the-world technique. Standard transfemoral access was used to the right internal carotid artery (ICA) with a 6F-Shuttle sheath and intracranial carotid with a 6F-Sofia distal access catheter. With dual-microcatheter access, 1 catheter was placed in the aneurysm dome, a second in the MCA for stent placement. Advancing the wire around the aneurysm first formed a loop from the lateral to medial wall for access to the MCA. The microcatheter was then advanced around the wire into the MCA, keeping the loop within the dome. With the loop's distal tip anchored, the distal end of the stent was deployed and anchored into the MCA. Both pitfalls (ie, lack of sufficient distal access, collapse of stent device during deployment) were resolved using a balloon catheter. With the balloon positioned and inflated as the anchor, the wire and catheter were pulled together. The loop in the aneurysm's dome straightened out across the neck, the stent was advanced into the MCA, and coiling proceeded. A large neck remnant had partially closed on 6-mo follow-up angiogram. Patient consented to undergo the procedure. Illustrations in video published/printed with permission from Mayfield Clinic.
Stent-Assisted Coiling of a Sidewall Aneurysm of the Distal Middle Cerebral Artery: 2-Dimensional Operative Video
Cavalcanti, Daniel D. , Delavari, Nader , Riina, Howard A. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levy, Elad, Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Schirmer, Clemens M , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael R. , Levy, E, Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E37-E38

10.1093/ons/opaa332 Get It

Abstract Sidewall aneurysm treatment often requires complex management strategies. These can include advanced clipping techniques or stent-assisted coiling techniques. Endovascular coiling alone has been associated with high recurrence rates and is often not feasible. 1-4 Flow-diversion embolization has recently become a standard of care for many aneurysms, demonstrating high occlusion rates. 4,5 However, the third generation of coil-assist stents can be delivered with 0.0165” microcatheters, being an ideal adjunct to manage this group of aneurysms in more distal locations. In this video, a 16-yr-old teenager with Parry-Romberg syndrome and congenital adrenal hyperplasia had an incidental finding of a 6.5-mm sidewall aneurysm arising off the angular branch of the left middle cerebral artery, found during the work-up of complex partial seizures. The patient consented to the procedure. Due to his young age and aneurysm size, a decision was made to treat the aneurysm through an endovascular approach. Under general anesthesia, a transfemoral approach was carried out using a 6-French short sheath. A 6-French guiding catheter was left in the distal cervical left internal carotid artery; a 0.0165” microcatheter was used to first deploy a 3.0 × 15 mm Neuroform Atlas stent, completely covering the length of the aneurysm. Then, the stent was traversed with the microcatheter to coil the aneurysm. Follow-up cerebral angiogram confirmed complete occlusion of the aneurysm.
The Use of Antiplatelet Agents and Heparin in the 24-Hour Postintravenous Alteplase Window for Neurointervention
Binning, Mandy J., Maxwell, Christina R. , McAree, Michael, Veznedaroglu, Erol, Wolfe, Stacey Q , Tschoe, Christine , Crowley, R. Webster , Vakharia, Kunal , Hamid, H , Ringer, Andrew J. , Liebman, Kenneth, Wolfe, Stacey Quintero , Felbaum, Daniel R. , Arthur, Adam Stephen , Goyal, Nitin , Levy, Elad I. , Pandey, Aditya S , Daou, Badih Junior , Tawk, Rabih G.

Neurosurgery | November 13, 2020 | Volume: 88 | Issue: 4 | Pages: 746-750

10.1093/neuros/nyaa530 Get It

Abstract BACKGROUND Intravenous (IV) alteplase with mechanical thrombectomy has been found to be superior to alteplase alone in select patients with intracranial large vessel occlusion. Current guidelines discourage the use of antiplatelet agents or heparin for 24 h following alteplase. However, their use is often necessary in certain circumstances during thrombectomy procedures. OBJECTIVE To study the safety and outcomes in patients who received blood thinning medications for thrombectomy after IV Tissue-Type plasminogen activator (tPA). METHODS This is a multicenter retrospective review of the use of antiplatelet agents and/or heparin in patients within 24 h following tPA administration. Patient demographics, comorbidities, bleeding complications, and discharge outcomes were collected. RESULTS A series of 88 patients at 9 centers received antiplatelet medications and/or heparin anticoagulation following IV alteplase for revascularization procedures requiring stenting. The mean National Institutes of Health Stroke Scale (NIHSS) on admission was 14.6. Reasons for use of a stent included internal carotid artery occlusion in 74% of patients. Thrombolysis in cerebral infarction (TICI) 2b-3 revascularization was accomplished in 90% of patients. The rate of symptomatic intracranial hemorrhage (sICH) was 8%; this was not significantly different than the sICH rate for a matched group of patients not receiving antiplatelets or heparin during the same time frame. Functional independence at 90 d (modified Rankin Scale 0-2) was seen in 57.8% of patients. All-cause mortality was 12%. CONCLUSION The use of antiplatelet agents and heparin for stroke interventions following IV alteplase appears to be safe without significant increased risk of hemorrhagic complications in this group of patients when compared to control data and randomized controlled trials.
In Reply: May Cooler Heads Prevail During a Pandemic: Stroke in COVID-19 Patients or COVID-19 in Stroke Patients?
Jabbour, Pascal , Sweid, Ahmad , Tjoumakaris, Stavropoula , Piotin, Michel , Brinjikji, Waleed , Bekelis, Kimon , Raz, Eytan , Nimjee, Shahid M. , Hassan, Ameer E , Gonzalez, L. Fernando , Lavine, Sean D., Bendok, Bernard R. , Jabbour, Pascal , Hassan, Ameer E , Nimjee, Shahid M , Sourour, Nader Antoine , Lopes, Demetrius K. , Pandey, Aditya S , Hanel, Ricardó A. , Siddiqui, Adnan H. , Hasan, David

Neurosurgery | August 7, 2020 | Volume: 87 | Issue: 6 | Pages: E691-E693

10.1093/neuros/nyaa384 Get It

Construction of a comprehensive endovascular test bed for research and device development in mechanical thrombectomy in stroke
Reddy, Adithya , Liu, Yang , Cockrum, Joshua , Gebrezgiabhier, Daniel , Savastano, Luis E., Liu, Yang , Davis, Evan, Zheng, Yihao , Pandey, Aditya S , Shih, Albert J. , Savastano, Luis

Journal of Neurosurgery | April 9, 2020 | Volume: 134 | Issue: 4 | Pages: 1190-1197

10.3171/2020.1.jns192732 Get It

OBJECTIVE The development of new endovascular technologies and techniques for mechanical thrombectomy in stroke has greatly relied on benchtop simulators. This paper presents an affordable, versatile, and realistic benchtop simulation model for stroke. METHODS A test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with 3D-printed and commercially available cerebrovascular phantoms, a customized hydraulic system to generate physiological flow rate and pressure, and 2 types of embolus analogs (elastic and fragment-prone) capable of causing embolic occlusions under physiological flow. RESULTS The test bed was highly versatile and allowed realistic, radiation-free mechanical thrombectomy for stroke due to large-vessel occlusion with rapid exchange of geometries and phantom types. Of the transparent cerebrovascular phantoms tested, the 3D-printed phantom was the easiest to manufacture, the glass model offered the best visibility of the interaction between embolus and thrombectomy device, and the flexible model most accurately mimicked the endovascular system during device navigation. None of the phantoms modeled branches smaller than 1 mm or perforating arteries, and none underwent realistic deformation or luminal collapse from device manipulation or vacuum. The hydraulic system created physiological flow rate and pressure leading to iatrogenic embolization during thrombectomy in all phantoms. Embolus analogs with known fabrication technique, structure, and tensile strength were introduced and consistently occluded the middle cerebral artery bifurcation under physiological flow, and their interaction with the device was accurately visualized. CONCLUSIONS The test bed presented in this study is a low-cost, comprehensive, realistic, and versatile platform that enabled high-quality analysis of embolus–device interaction in multiple cerebrovascular phantoms and embolus analogs.
Analysis of human emboli and thrombectomy forces in large-vessel occlusion stroke
Liu, Yang , Reddy, Adithya , Gebrezgiabhier, Daniel , Cockrum, Joshua , Chaudhary, Neeraj , Griauzde, Julius, Shih, Albert J. , Savastano, Luis E., Liu, Yang , Chaudhary, Neeraj , Zheng, Yihao , Davis, Evan, Gemmete, Joseph John , Pandey, Aditya S , Savastano, Luis

Journal of Neurosurgery | March 6, 2020 | Volume: 134 | Issue: 3 | Pages: 893-901

10.3171/2019.12.jns192187 Get It

OBJECTIVE This study’s purpose was to improve understanding of the forces driving the complex mechanical interaction between embolic material and current stroke thrombectomy devices by analyzing the histological composition and strength of emboli retrieved from patients and by evaluating the mechanical forces necessary for retrieval of such emboli in a middle cerebral artery (MCA) bifurcation model. METHODS Embolus analogs (EAs) were generated and embolized under physiological pressure and flow conditions in a glass tube model of the MCA. The forces involved in EA removal using conventional endovascular techniques were described, analyzed, and categorized. Then, 16 embolic specimens were retrieved from 11 stroke patients with large-vessel occlusions, and the tensile strength and response to stress were measured with a quasi-static uniaxial tensile test using a custom-made platform. Embolus compositions were analyzed and quantified by histology. RESULTS Uniaxial tension on the EAs led to deformation, elongation, thinning, fracture, and embolization. Uniaxial tensile testing of patients’ emboli revealed similar soft-material behavior, including elongation under tension and differential fracture patterns. At the final fracture of the embolus (or dissociation), the amount of elongation, quantified as strain, ranged from 1.05 to 4.89 (2.41 ± 1.04 [mean ± SD]) and the embolus-generated force, quantified as stress, ranged from 63 to 2396 kPa (569 ± 695 kPa). The ultimate tensile strain of the emboli increased with a higher platelet percentage, and the ultimate tensile stress increased with a higher fibrin percentage and decreased with a higher red blood cell percentage. CONCLUSIONS Current thrombectomy devices remove emboli mostly by applying linear tensile forces, under which emboli elongate until dissociation. Embolus resistance to dissociation is determined by embolus strength, which significantly correlates with composition and varies within and among patients and within the same thrombus. The dynamic intravascular weakening of emboli during removal may lead to iatrogenic embolization.
The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil
Bendok, Bernard R. , Abi-Aad, Karl R., Ward, Jennifer , Kniss, Jason F , Kwasny, Mary , Rahme, Rudy J. , Aoun, Salah G. , Tecle, Najib E. El , Zammar, Samer G. , Aoun, Rami James N. , Patra, Devi Prasad, Raymond, Jean , Woo, Henry H. , Dabus, Guilherme , Milot, Geneviève , Scott, John A. , DeNardo, Andrew , Investigators, HEAT Study, Lavine, Sean D., Bozorgchami, Hormozd, Veznedaroglu, Erol, Albuquerque, Felipe C. , Fiorella, David, Boulos, Alan S. , Cortes, Maria, Kanaan, Hilal, Jindal, Gaurav , Klucznik, Richard , Kalmes, David, Xavier, Andrew, Hussain, Muhammad , Moran, Christopher J. , Adel, Brian van , Milot, Genevieve, Hirsch, Joshua A , Carpenter, Jeffrey , Powers, Ciarán J. , Luh, George, Tummala, Ramanchandra, Evans, Avery J. , Garg, Ankur, James, Roberts, Sauvageau, Eric , Fields, Jeremy D. , Grobelny, Thomas, Hartman, J., Patra, Devi P. , Bendok, Bernard R , Ward, Jennifer D, Ahmadieh, Tarek Y. El , Ansari, Sameer A. , Fiorella, David , Dabus, Guilherme C. , Almandoz, Josser E Delgado , Dashti, Shervin R , Investigators, HEAT Study, Deshaies, Eric Michael , Fiorella, David, Tawk, Rabih G. , Romero, Charles, Kelly, Michael , Chaudry, Imran , Pandey, Aditya S , Wang, Dennis Y.Q. , Milot, Genevieve, Jabbour, Pascal , Shankar, Jai , Patsalides, Athos T , Lee, Sung , James, Robert F. , Jayaraman, Mahesh V. , Satti, Sudhakar R

Neurosurgery | February 10, 2020 | Volume: 86 | Issue: 5 | Pages: 615-624

10.1093/neuros/nyaa006 Get It

Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract