Back to Authors

Zheng, Yihao

0000-0003-4110-4175

Mayo Clinic

Worcester Polytechnic Institute

Citations 5

Unifying theory of carotid plaque disruption based on structural phenotypes and forces expressed at the lumen/wall interface
Mousavi, H A Ebrahimzadeh, Liu, Yang , Khalsa, Siri Sahib S. , Reddy, Adithya , Brinjikji, Waleed , Bhambri, Ankur, Cockrum, Joshua , Thompson, B. Gregory , Seibel, Eric J. , Yonas, Howard, Savastano, Luis , Liu, Yang , Zheng, Yihao , Mousavi, Hossein, Davis, Evan, Pandey, Aditya S , Gordon, David J.

Stroke and Vascular Neurology | June 1, 2022 | Volume: 7 | Issue: 6 | Pages: 465-475

10.1136/svn-2021-001451 Get It

Objectives To integrate morphological, haemodynamic and mechanical analysis of carotid atheroma driving plaque disruption. Materials and methods First, we analysed the phenotypes of carotid endarterectomy specimens in a photographic dataset A, and matched them with the likelihood of preoperative stroke. Second, laser angioscopy was used to further define the phenotypes in intact specimens (dataset B) and benchmark with histology. Third, representative vascular geometries for each structural phenotype were analysed with Computational Fluid Dynamics (CFD), and the mechanical strength of the complicated atheroma to resist penetrating forces was quantified (n=14). Results In dataset A (n=345), ulceration (fibrous cap disruption) was observed in 82% of all plaques, intraplaque haemorrhage in 68% (93% subjacent to an ulcer) and false luminal formation in 48%. At least one of these ‘rupture’ phenotypes was found in 97% of symptomatic patients (n=69) compared with 61% in asymptomatic patients. In dataset B (n=30), laser angioscopy redemonstrated the structural phenotypes with near-perfect agreement with histology. In CFD, haemodynamic stress showed a large pulse magnitude, highest upstream to the point of maximal stenosis and on ulceration the inflow stream excavates the necrotic core cranially and then recirculates into the true lumen. Based on mechanical testing (n=14), the necrotic core is mechanically weak and penetrated by the blood on fibrous cap disruption. Conclusions Fibrous cap ulceration, plaque haemorrhage and excavation are sequential phenotypes of plaque disruption resulting from the chiselling effect of haemodynamic forces over unmatched mechanical tissue strength. This chain of events may result in thromboembolic events independently of the degree of stenosis.
Abstract P507: Clot Ingestion Leads to the Highest First Pass Complete Recanalization Rates in a Human Brain Model of Large Vessel Occlusion Stroke
Reddy, Adithya , Savastano, Luis , Liu, Yang , Gebrezgiabhier, Daniel , Davis, Evan, Zheng, Yihao , Shih, Albert J. , Larco, Jorge Arturo , Pandey, Aditya S

Stroke | March 11, 2021 | Volume: 52 | Issue: Suppl_1 | Pages: No page available

10.1161/str.52.suppl_1.p507 Get It

Introduction: Suction catheters and stent retrievers are based on the classical paradigm of “en bloc” removal of emboli by generation of tensile forces by vacuum or device withdrawal. However, in this process emboli elongate and fracture leading to fragmentation. Fragments can migrate downstream or remain impacted in the arterial wall resulting in a residual occlusion. Hypothesis: Clot ingestion is biomechanically superior to “en bloc” removal and leads to higher recanalization rates with less complications. Methods: To test this hypothesis, we present a hybrid test bed consisting of pressurized human brains which was developed and validated for large vessel occlusion (LVO) and revascularization. We fabricated 3 types of representative embolus analogs (EAs) (elastic, fragment-prone and stiff) and recreated 105 LVO in twenty-four fresh human brains with the vasculature connected to an hydraulic system to mimic physiological flow and pressures. Recanalization was attempted in 61 LVO cases by Direct Aspiration (DA) using an 068 catheter and in 44 LVO cases combining Stent Retriever with Aspiration (SR+A). Rates of successful recanalization (SR, Grade 2b or higher) and complete recanalization (CR, Grade 2c or higher) were measured. Up to 4 attempts were done before declaring a failure (Grade 2a or lower). Results: DA resulted in 90% of SR, 79% of CR, 61% of first pass SR and 49% of first pass CR. SR+A resulted in 34% of SR, 34% of CR, 23% of first pass SR and 14% of first pass CR. Elastic EA were associated with 88% of SR, 85% of CR, 61% of first pass SR and 52% of first pass CR. Stiff EAs were associated with 64% of SR, 64% of CR, 36% of first pass SR and 36% of first pass CR. Fragment-prone EAs were associated with 64% of SR, 40% of CR, 38% of first pass SR and 21% of first pass CR. Conclusion: Clot ingestion is biomechanically superior to “en bloc” removal and leads to the highest rates of SR, CR and first pass recanalization. DA achieves higher recanalization rates than SR+A. Elastic clots are associated with the highest rates or recanalization, followed by stiff clots and finally by fragment-prone clots.
A human brain test bed for research in large vessel occlusion stroke
Gebrezgiabhier, Daniel , Liu, Yang , Reddy, Adithya , Savastano, Luis E., Liu, Yang , Davis, Evan, Zheng, Yihao , Shih, Albert J. , Pandey, Aditya S , Savastano, Luis

Journal of Neurosurgery | January 22, 2021 | Volume: 135 | Issue: 4 | Pages: 1072-1080

10.3171/2020.7.jns202278 Get It

OBJECTIVE Endovascular removal of emboli causing large vessel occlusion (LVO)–related stroke utilizing suction catheter and/or stent retriever technologies or thrombectomy is a new standard of care. Despite high recanalization rates, 40% of stroke patients still experience poor neurological outcomes as many cases cannot be fully reopened after the first attempt. The development of new endovascular technologies and techniques for mechanical thrombectomy requires more sophisticated testing platforms that overcome the limitations of phantom-based simulators. The authors investigated the use of a hybrid platform for LVO stroke constructed with cadaveric human brains. METHODS A test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with cadaveric human brains, a customized hydraulic system to generate physiological flow rate and pressure, and three types of embolus analogs (elastic, stiff, and fragment-prone) engineered to match mechanically and phenotypically the emboli causing LVO strokes. LVO cases were replicated in the anterior and posterior circulation, and thrombectomy was attempted using suction catheters and/or stent retrievers. RESULTS The test bed allowed radiation-free visualization of thrombectomy for LVO stroke in real cerebrovascular anatomy and flow conditions by transmural visualization of the intraluminal elements and procedures. The authors were able to successfully replicate 105 LVO cases with 184 passes in 12 brains (51 LVO cases and 82 passes in the anterior circulation, and 54 LVO cases and 102 passes in the posterior circulation). Observed recanalization rates in this model were graded using a Recanalization in LVO (RELVO) scale analogous to other measures of recanalization outcomes in clinical use. CONCLUSIONS The human brain platform introduced and validated here enables the analysis of artery-embolus-device interaction under physiological hemodynamic conditions within the unmodified complexity of the cerebral vasculature inside the human brain.
Construction of a comprehensive endovascular test bed for research and device development in mechanical thrombectomy in stroke
Reddy, Adithya , Liu, Yang , Cockrum, Joshua , Gebrezgiabhier, Daniel , Savastano, Luis E., Liu, Yang , Davis, Evan, Zheng, Yihao , Pandey, Aditya S , Shih, Albert J. , Savastano, Luis

Journal of Neurosurgery | April 9, 2020 | Volume: 134 | Issue: 4 | Pages: 1190-1197

10.3171/2020.1.jns192732 Get It

OBJECTIVE The development of new endovascular technologies and techniques for mechanical thrombectomy in stroke has greatly relied on benchtop simulators. This paper presents an affordable, versatile, and realistic benchtop simulation model for stroke. METHODS A test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with 3D-printed and commercially available cerebrovascular phantoms, a customized hydraulic system to generate physiological flow rate and pressure, and 2 types of embolus analogs (elastic and fragment-prone) capable of causing embolic occlusions under physiological flow. RESULTS The test bed was highly versatile and allowed realistic, radiation-free mechanical thrombectomy for stroke due to large-vessel occlusion with rapid exchange of geometries and phantom types. Of the transparent cerebrovascular phantoms tested, the 3D-printed phantom was the easiest to manufacture, the glass model offered the best visibility of the interaction between embolus and thrombectomy device, and the flexible model most accurately mimicked the endovascular system during device navigation. None of the phantoms modeled branches smaller than 1 mm or perforating arteries, and none underwent realistic deformation or luminal collapse from device manipulation or vacuum. The hydraulic system created physiological flow rate and pressure leading to iatrogenic embolization during thrombectomy in all phantoms. Embolus analogs with known fabrication technique, structure, and tensile strength were introduced and consistently occluded the middle cerebral artery bifurcation under physiological flow, and their interaction with the device was accurately visualized. CONCLUSIONS The test bed presented in this study is a low-cost, comprehensive, realistic, and versatile platform that enabled high-quality analysis of embolus–device interaction in multiple cerebrovascular phantoms and embolus analogs.
Analysis of human emboli and thrombectomy forces in large-vessel occlusion stroke
Liu, Yang , Reddy, Adithya , Gebrezgiabhier, Daniel , Cockrum, Joshua , Chaudhary, Neeraj , Griauzde, Julius, Shih, Albert J. , Savastano, Luis E., Liu, Yang , Chaudhary, Neeraj , Zheng, Yihao , Davis, Evan, Gemmete, Joseph John , Pandey, Aditya S , Savastano, Luis

Journal of Neurosurgery | March 6, 2020 | Volume: 134 | Issue: 3 | Pages: 893-901

10.3171/2019.12.jns192187 Get It

OBJECTIVE This study’s purpose was to improve understanding of the forces driving the complex mechanical interaction between embolic material and current stroke thrombectomy devices by analyzing the histological composition and strength of emboli retrieved from patients and by evaluating the mechanical forces necessary for retrieval of such emboli in a middle cerebral artery (MCA) bifurcation model. METHODS Embolus analogs (EAs) were generated and embolized under physiological pressure and flow conditions in a glass tube model of the MCA. The forces involved in EA removal using conventional endovascular techniques were described, analyzed, and categorized. Then, 16 embolic specimens were retrieved from 11 stroke patients with large-vessel occlusions, and the tensile strength and response to stress were measured with a quasi-static uniaxial tensile test using a custom-made platform. Embolus compositions were analyzed and quantified by histology. RESULTS Uniaxial tension on the EAs led to deformation, elongation, thinning, fracture, and embolization. Uniaxial tensile testing of patients’ emboli revealed similar soft-material behavior, including elongation under tension and differential fracture patterns. At the final fracture of the embolus (or dissociation), the amount of elongation, quantified as strain, ranged from 1.05 to 4.89 (2.41 ± 1.04 [mean ± SD]) and the embolus-generated force, quantified as stress, ranged from 63 to 2396 kPa (569 ± 695 kPa). The ultimate tensile strain of the emboli increased with a higher platelet percentage, and the ultimate tensile stress increased with a higher fibrin percentage and decreased with a higher red blood cell percentage. CONCLUSIONS Current thrombectomy devices remove emboli mostly by applying linear tensile forces, under which emboli elongate until dissociation. Embolus resistance to dissociation is determined by embolus strength, which significantly correlates with composition and varies within and among patients and within the same thrombus. The dynamic intravascular weakening of emboli during removal may lead to iatrogenic embolization.