Transorbital Surgical Corridor: An Anatomic Analysis of Ocular Globe Retraction and the Associated Exposure for the Transpalpebral Orbital Rim Preserving Endoscopic Orbitotomy (TORPEDO) Approach
BACKGROUND AND OBJECTIVES: The transorbital approach varies by the extent of bony removal and the target. Orbital rim-sparing transorbital approach with removal of only the orbit's posterior wall provides optimal cosmetic results, without the need for reconstruction. The size of this corridor, limited by the medial globe retraction, has not yet been defined and is difficult to determine in cadavers because of postmortem tissue desiccation. By using patient-specific models in virtual reality, precise areas and degrees of surgical freedom (AOF and DOF, respectively) provided by globe retraction were calculated. These measurements define a potential maximum safe AOF and DOF, as well as the globe retraction, needed to achieve a sufficient surgical corridor. METHODS: Using a virtual reality system, transorbital rim-preserving craniectomies were performed. The axial and sagittal DOF as well as AOF were calculated lateral to the globe, limited by the orbital rim and globe, with an anterior clinoid target. The DOFs and AOFs were calculated for each degree of medial globe retraction and analyzed using paired t tests. RESULTS: With only 5 mm of retraction, the AOF was 886 mm 2 , while at 10 mm, the AOF was 1546 mm 2 . This increase between 5 and 10 mm allowed for the largest increase in surgical working corridor ( P = .02). At 15 mm of retraction (previously studied point at which intraocular pressure raises), the AOF averaged 2189 mm 2 and axial DOF averaged 23.1°. Eighteen DOF (a previously studied point needed to achieve sufficient working space for 2 instruments) was achieved at 11 mm on average, generating 1675 mm 2 AOF. CONCLUSION: Globe retraction of 11 mm is needed to achieve sufficient DOF for 2 surgical instruments, and 15 mm of retraction is a conservative limit that provides comparable AOFs with similar cranial approaches.
The Use of Antiplatelet Agents and Heparin in the 24-Hour Postintravenous Alteplase Window for Neurointervention
Abstract BACKGROUND Intravenous (IV) alteplase with mechanical thrombectomy has been found to be superior to alteplase alone in select patients with intracranial large vessel occlusion. Current guidelines discourage the use of antiplatelet agents or heparin for 24 h following alteplase. However, their use is often necessary in certain circumstances during thrombectomy procedures. OBJECTIVE To study the safety and outcomes in patients who received blood thinning medications for thrombectomy after IV Tissue-Type plasminogen activator (tPA). METHODS This is a multicenter retrospective review of the use of antiplatelet agents and/or heparin in patients within 24 h following tPA administration. Patient demographics, comorbidities, bleeding complications, and discharge outcomes were collected. RESULTS A series of 88 patients at 9 centers received antiplatelet medications and/or heparin anticoagulation following IV alteplase for revascularization procedures requiring stenting. The mean National Institutes of Health Stroke Scale (NIHSS) on admission was 14.6. Reasons for use of a stent included internal carotid artery occlusion in 74% of patients. Thrombolysis in cerebral infarction (TICI) 2b-3 revascularization was accomplished in 90% of patients. The rate of symptomatic intracranial hemorrhage (sICH) was 8%; this was not significantly different than the sICH rate for a matched group of patients not receiving antiplatelets or heparin during the same time frame. Functional independence at 90 d (modified Rankin Scale 0-2) was seen in 57.8% of patients. All-cause mortality was 12%. CONCLUSION The use of antiplatelet agents and heparin for stroke interventions following IV alteplase appears to be safe without significant increased risk of hemorrhagic complications in this group of patients when compared to control data and randomized controlled trials.