Back to Authors

Denard, Patrick J

0000-0002-2641-5920

Mayo Clinic

Southern Oregon Orthopedics, Medford, OR, USA.

Citations 5

Compression of an Autograft Biceps Into an Augmentation Patch Does Not Cause Mechanical Damage to the Tenocyte
Brinkman, Joseph C. , Makovicka, Justin L. , Denard, Patrick J. , Colbath, Gregory, Mercuri, Jeremy , Tokish, John M., Denard, Patrick J

Arthroscopy | September 26, 2024 | Volume: 41 | Issue: 6 | Pages: 1745-1751

10.1016/j.arthro.2024.09.029 Get It

Purpose To evaluate the effects of this graft preparation technique on histologic evidence of tenocyte mechanical damage. Methods A consecutive series of patients undergoing biceps tenodesis for shoulder pathology were evaluated. After suprapectoral tenodesis, 27 mm of the long head of the biceps was secured for compression into the patch. The remaining length of the residual tendon was longitudinally split, resulting in 2 equal lengths of remnant tendon from the same zone. One sample was sent to pathology with no preparation, and the other was prepared as a compressed biceps autograft patch according to the manufacturer’s recommendations. Both grafts were sent to pathology for evaluation of tenocyte morphology. Records were reviewed to determine if compression resulted in mechanical damage to the tenocytes at the time of biceps augmentation. Results Fifty‐five shoulder procedures and 110 samples were sent for pathology analysis. Forty‐two of the 55 (76%) specimens demonstrated morphologically normal tenocytes in both the compressed and noncompressed groups, and 7 (13%) cases showed evidence of tenocyte necrosis or mechanical damage in both groups. The difference in abnormal tenocyte morphology between the compressed and native groups was not statistically significant ( P = .625). Conclusions Autograft biceps compression into a point‐of‐care patch did not result in mechanical damage to tenocyte morphology at the time of insertion for augmentation of rotator cuff pathology. Clinical Relevance Free proximal biceps tendon compression can result in a patch that does not mechanically damage the tenocyte. The patch can be used as a biologic autograft to enhance shoulder rotator cuff repair, as well as subscapularis repair in the setting of shoulder arthroplasty.
Identification of ChatGPT‐Generated Abstracts Within Shoulder and Elbow Surgery Poses a Challenge for Reviewers
Stadler, Ryan D. , Sudah, Suleiman Y. , Denard, Patrick J. , Duralde, Xavier A. , Garrigues, Grant E. , Klifto, Christopher S. , Namdari, Surena , Sánchez‐Sotelo, Joaquín , Menendez, Mariano E. , Sanchez-Sotelo, Joaquin, Sanchez-Sotelo, J. , Denard, Patrick J , Moverman, Michael A. , Levy, Jonathan C., Menendez, Mariano E.

Arthroscopy | July 9, 2024 | Volume: 41 | Issue: 4 | Pages: 916

10.1016/j.arthro.2024.06.045 Get It

Purpose To evaluate the extent to which experienced reviewers can accurately discern between artificial intelligence (AI)–generated and original research abstracts published in the field of shoulder and elbow surgery and compare this with the performance of an AI detection tool. Methods Twenty‐five shoulder‐ and elbow‐related articles published in high‐impact journals in 2023 were randomly selected. ChatGPT was prompted with only the abstract title to create an AI‐generated version of each abstract. The resulting 50 abstracts were randomly distributed to and evaluated by 8 blinded peer reviewers with at least 5 years of experience. Reviewers were tasked with distinguishing between original and AI‐generated text. A Likert scale assessed reviewer confidence for each interpretation, and the primary reason guiding assessment of generated text was collected. AI output detector (0%‐100%) and plagiarism (0%‐100%) scores were evaluated using GPTZero. Results Reviewers correctly identified 62% of AI‐generated abstracts and misclassified 38% of original abstracts as being AI generated. GPTZero reported a significantly higher probability of AI output among generated abstracts (median, 56%; interquartile range [IQR], 51%‐77%) compared with original abstracts (median, 10%; IQR, 4%‐37%; P < .01). Generated abstracts scored significantly lower on the plagiarism detector (median, 7%; IQR, 5%‐14%) relative to original abstracts (median, 82%; IQR, 72%‐92%; P < .01). Correct identification of AI‐generated abstracts was predominately attributed to the presence of unrealistic data/values. The primary reason for misidentifying original abstracts as AI was attributed to writing style. Conclusions Experienced reviewers faced difficulties in distinguishing between human and AI‐generated research content within shoulder and elbow surgery. The presence of unrealistic data facilitated correct identification of AI abstracts, whereas misidentification of original abstracts was often ascribed to writing style. Clinical Relevance With rapidly increasing AI advancements, it is paramount that ethical standards of scientific reporting are upheld. It is therefore helpful to understand the ability of reviewers to identify AI‐generated content.
Compressed Biceps Autograft Augmentation of Arthroscopic Rotator Cuff Repair
Tokish, John M. , Shaha, James S., Denard, Patrick J. , Mercuri, Jeremy , Colbath, Gregory, Denard, Patrick J

Arthroscopy Techniques | October 20, 2022 | Volume: 11 | Issue: 11 | Pages: No page available

10.1016/j.eats.2022.08.011 Get It

Abstract Rotator cuff repair failure rates continue to be a challenging problem. Various methods of biological and structural augmentation of the rotator cuff have been explored to improve tendon healing after repair. We describe a technique in which biceps tendon autograft is harvested after tenodesis. The biceps tendon is then compressed into a patch that is placed over the repaired rotator cuff tendon. Repurposing the portion of the tendon that is otherwise discarded offers several advantages over other augmentations that have been used, including the biological potential of live autograft tenocytes in the patch, lower cost, and no donor‐site morbidity. Technique Video video See video under supplementary data.
The addition of preoperative three-dimensional analysis alters implant choice in shoulder arthroplasty
Werner, Brian C. , Denard, Patrick J. , Tokish, John M. , Bedi, Asheesh , Donegan, Ryan P., Metcalfe, Nick, Denard, Patrick J , Dines, Joshua S.

Shoulder & Elbow | February 2, 2021 | Volume: 14 | Issue: 4 | Pages: 378-384

10.1177/1758573221989306 Get It

Background The primary objective of the present study was to investigate how preoperative imaging modalities including 3D computed tomography (CT) scans with preoperative planning software affect implant choice for shoulder arthroplasty. Methods X-ray, uncorrected 2D CT scans, and 3D CT scans from 21 patients undergoing primary arthroplasty were reviewed by five shoulder surgeons. Each surgeon measured glenoid version, inclination and humeral head subluxation, and then selected an anatomic or reverse shoulder arthroplasty implant based only on these imaging parameters. Each surgeon virtually positioned the implant. Agreement between surgeons and changes in plan for individual surgeons between imaging modalities were assessed. Results Average measurements of native version, inclination, and subluxation were similar across all imaging modalities with very good interobserver reliability. Overall, there was a high rate of variability in choice of implant depending on imaging modality. Agreement on implant selection between surgeons improved from 68.6% using x-ray to 80.0% with 3D CT. Introducing age added significant variability, reducing agreement on implant choice to 61.0% with 3D CT. Conclusions The use of preoperative 3D planning changes implant choice in nearly one-third of cases compared to plain radiographs and improves surgeon agreement on implant choice compared to x-ray and 2D CT. Level of evidence: III.
Radiographic parameters associated with excellent versus poor range of motion outcomes following reverse shoulder arthroplasty
Lädermann, Alexandre , Parsons, Bradford O. , Tokish, John M. , Denard, Patrick J. , Lädermann, Alexandre , Lädermann, Alexandre , Denard, Patrick J , Haidamous, Georges , Hartzler, Robert U. , Lederman, Evan

Shoulder & Elbow | July 10, 2020 | Volume: 14 | Issue: 1 | Pages: 39-47

10.1177/1758573220936234 Get It

Background The purpose was to evaluate the relationship of component size and position to postoperative range of motion following reverse shoulder arthroplasty. The hypothesis was that increased lateralization, larger glenospheres, and a decreased acromiohumeral distance would be associated with excellent postoperative range of motion. Methods A retrospective multicenter study was performed at a minimum of one year postoperatively on 160 patients who underwent primary reverse shoulder arthroplasty with a 135° humeral component. Outcomes were stratified based on postoperative forward flexion and external rotation into excellent ( n = 42), defined as forward flexion >140° and external rotation > 30°, or poor ( n = 36), defined as forward flexion <100° and external rotation < 15°. Radiographic measurements and component features were compared between the two groups. Results A larger glenosphere size was associated with an excellent outcome ( p = 0.009). A 2-mm posterior offset humeral cup ( p = 0.012) and an increased inferior glenosphere overhang (3.1 mm vs 1.4 mm; p = 0.002) were also associated with excellent outcomes. Humeral lateralization and distalization were not associated with an excellent outcome. Conclusion: Larger glenosphere size and inferior positioning as well as posterior humeral offset are associated with improved postoperative range of motion following reverse shoulder arthroplasty. Level of Evidence Level 3, retrospective comparative study.