Background: Limited data exist that show the long-term risks of reinfection and mechanical failure with a contemporary 2-stage exchange protocol for periprosthetic joint infection following total hip arthroplasty. The purpose of this study was to determine the long-term reinfection and mechanical failure rates of 2-stage exchange for periprosthetic joint infection after total hip arthroplasty. Methods: We identified 164 hips (162 patients) with infection after total hip arthroplasty between 1991 and 2006 treated with a 2-stage exchange protocol with no prior treatment for periprosthetic joint infection. With regard to Musculoskeletal Infection Society diagnostic criteria, at least 1 major criterion or 4 of 6 minor criteria were fulfilled in 129 hips (79%). The cumulative incidence with a competing risk of death was calculated for reinfection, aseptic revisions, and all-cause revisions. The risk factors for reinfection were evaluated using Cox proportional hazards regression. Harris hip scores were calculated. The mean age at the time of spacer insertion was 68 years, and 35% of the patients were female. Excluding the patients with <2 years of follow-up, the mean follow-up was 12 years (range, 2 to 21 years). Results: The cumulative incidence of recurrence of infection was 10% at 1 year, 14% at 5 years, and 15% at 10 and 15 years. Seventeen patients (11%) used chronic antibiotic suppression (>6 months), with 7 (41%) of these having recurrent infection at the time of the latest follow-up. Use of chronic antibiotic suppression was the only predictive factor for reinfection (hazard ratio, 4.5 [95% confidence interval (CI), 1.9 to 10.9]; p = 0.001). The cumulative incidence of aseptic femoral and acetabular revisions was 2.6% at 5 years and 3.3% at 10 and 15 years. The cumulative incidence of all-cause revisions was 15% at 5 years and 16% at 10 and 15 years. Dislocation was the most common complication, with 28 dislocations occurring in 20 patients (12%). The mean Harris hip score improved from 52 points prior to spacer insertion to 70 points at 15 years after reimplantation (p < 0.01). Conclusions: The rate of recurrence of infection of 15% for up to 15 years after total hip arthroplasty was similar to previous shorter-term reports of 2-stage exchange for periprosthetic joint infection. Surgeons should anticipate mitigating instability after reimplantation. Implant survivorship free of aseptic loosening and clinical outcomes were preserved for the long term. The role of chronic antibiotic suppression in the long-term treatment of periprosthetic joint infection requires further investigation. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Two-Stage Exchange and Marlex-Mesh Reconstruction for Infection with Extensor Mechanism Disruption After Total Knee Arthroplasty
Background: Periprosthetic joint infection (PJI) of the knee with concurrent disruption of the extensor mechanism is a devastating complication. Historically, knees with such complications have been salvaged with use of an arthrodesis or amputation. The purpose of this study was to assess the survival and functional outcomes of a 2-stage exchange arthroplasty combined with knitted monofilament polypropylene (Marlex; C.R. Bard) mesh reconstruction of the extensor mechanism. Methods: From 2000 to 2015, 16 patients underwent a 2-stage exchange arthroplasty and Marlex-mesh reconstruction for PJI with an extensor mechanism disruption. The study included 9 male patients and 7 female patients with a mean age at the time of reimplantation and mesh reconstruction of 64 years. The mean follow-up was 4 years. PJI was diagnosed on the basis of the Musculoskeletal Infection Society criteria. Clinical outcomes, including survivorship, Knee Society Score (KSS) results, and complications, were assessed. Results: Of 16 reconstructions, 13 were in place at the time of the latest follow-up. At 2 years, survivorship free of mesh failure was 86%, survivorship free of PJI was 87%, and survivorship free of PJI or mesh failure was 75%. The mean KSS improved from 48 prior to resection to 74 after mesh reconstruction and reimplantation. The mean extensor lag improved from 31° prior to resection to 3° after mesh reconstruction. Two patients required mesh revision, 1 patient required an above-the-knee amputation for complex wound complications related to reinfection, 1 patient developed a reinfection requiring irrigation and debridement, and 1 patient developed a superficial infection that required debridement. Conclusions: Two-stage exchange arthroplasty combined with Marlex-mesh reconstruction of the extensor mechanism is a viable alternative to knee arthrodesis or amputation. At 2 years, 75% of mesh reconstructions were in place and without evidence of PJI. Moreover, the functional outcomes were improved, with a negligible extensor lag. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Extensor Mechanism Reconstruction with Use of Marlex Mesh
Background: Disruption of the extensor mechanism after total knee arthroplasty (TKA) is debilitating, and the reported results of numerous reconstructive options have varied. We previously reported the early results of 13 patients who underwent reconstruction of the extensor mechanism with use of Marlex mesh. The purpose of the current study was to assess results in a larger cohort of patients, with an emphasis on the survivorship of the mesh, clinical results, and complications. Methods: During the period of 2000 to 2015 at a single tertiary care academic institution, 77 patients (77 TKAs) underwent reconstruction with use of Marlex mesh for an extensor mechanism disruption (27 quadriceps tendon disruptions, 40 patellar tendon disruptions, and 10 patellar fractures). The mean patient age at the time of reconstruction was 65 years; 70% of the patients were female. The mean body mass index was 35 kg/m 2 . The mean follow-up was 4 years. Eighteen (23%) of the patients underwent mesh reconstruction with the primary TKA in place, and 59 (77%) had mesh reconstruction at the time of revision TKA. The mean time between disruption and reconstruction was 7 months. Twenty (26%) of the patients had previously undergone attempted extensor mechanism reconstruction at outside institutions. Results: Sixty-five of the 77 mesh reconstructions were in place at the time of the latest follow-up. Twelve patients experienced a failure that required mesh revision: 5 for patellar tendon rupture, 5 for quadriceps tendon rupture, and 2 for symptomatic lengthening. Four additional patients with mesh failure were treated nonoperatively with bracing. The 2-year survivorship free of mesh revision was 86% for patients with no prior reconstruction and 95% for patients with previous reconstructions of the extensor mechanism that did not involve Marlex mesh. Knee Society Score (KSS) results significantly improved following reconstruction (p < 0.001). Extensor lag improved by a mean of 26°, with mean postoperative extensor lag measuring 9° (p < 0.001). Conclusions: Reconstruction of the extensor mechanism with use of Marlex mesh is a viable option in patients with catastrophic disruption after TKA. At the time of the latest follow-up, 84% of the mesh reconstructions were in place and the functional outcomes were excellent, with mean improvement in extensor lag of 26°. Extended follow-up is required, but the results of this large series with a mean follow-up of 4 years are encouraging. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Intravenous Versus Topical Tranexamic Acid in Total Knee Arthroplasty
Background: Tranexamic acid (TXA) reduces bleeding and the need for transfusion after total knee arthroplasty. Most literature has focused on intravenous (IV) administration of TXA, with less data available on the efficacy of topically administered TXA. This multicenter randomized clinical trial specifically assessed the efficacy of topical TXA compared with IV TXA as measured by calculated blood loss, drain output, and transfusion rates. Complications, including venous thromboembolism (VTE), were reported. Methods: A total of 640 patients who underwent primary unilateral total knee arthroplasty for osteoarthritis at 2 large academic centers were randomized to receive 1 g of IV TXA prior to tourniquet inflation and 1 g at closure, or 3 g of TXA diluted in 45 mL of normal saline solution (total volume of 75 mL) and topically applied after cementation. Age, sex, body mass index, American Society of Anesthesiologists (ASA) score, and preoperative hemoglobin level were similar between the groups. Univariate, multiple linear regression, and multiple logistic regression analyses were performed. Results: Patients who received topical TXA had significantly greater calculated blood loss compared with those who received IV TXA (mean of 324 compared with 271 mL; p = 0.005). Drain output was significantly higher in the topical TXA group compared with the IV TXA group (mean of 560 compared with 456 mL; p < 0.0001). The rate of transfusion was low in the topical and IV groups, with no significant difference on univariate analysis (1.6% compared with 0.6%, respectively; p = 0.45); however, on multiple logistic regression analysis, patients who received topical TXA were 2.2-fold more likely to receive a transfusion (p < 0.0001). The topical and IV TXA groups did not differ significantly with respect to the rate of thrombotic events (0.6% compared with 1.6%, respectively; p = 0.45). Conclusions: In this large, randomized clinical trial involving patients undergoing total knee arthroplasty, both IV and topical TXA were associated with a low rate of transfusion. While IV TXA was associated with less calculated blood loss, lower drain output, and fewer transfusions, the small differences between the groups may not be clinically important. Given the low prevalence of thrombotic complications, the relative safety of one formulation of TXA over the other cannot be definitely established. Level of Evidence: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
Effect of Postoperative Mechanical Axis Alignment on Survival and Functional Outcomes of Modern Total Knee Arthroplasties with Cement
Abstract: We previously compared the 15-year survivorship of total knee arthroplasty (TKA) implants that were mechanically aligned (0° ± 3° relative to the mechanical axis) compared with those that were outside that range and considered outliers. The original publication included 398 TKAs (292 in the aligned group and 106 in the outlier group) performed from 1985 to 1990. At the time of follow-up in the previous study, 138 patients (155 TKAs) had died and 59 knees had been revised. Since that publication, 49 additional patients (87 knees) have died. At 20 years, 57 (19.5%) of the 292 knees in the mechanically aligned group had been revised compared with 16 (15.1%) of the 106 knees in the outlier group (p = 0.97). Postoperative alignment within 0° ± 3° of the mechanical axis did not provide a functional advantage at 1, 5, 10, 15, and/or 20 years postoperatively as demonstrated by the Knee Society scores being similar between the groups (p ≥ 0.2 at all intervals). At 20 years, we once again did not find that neutral mechanical alignment provided better implant survivorship than that found in the outlier group. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.