Back to Authors

Asirvatham, Samuel J

0000-0001-9835-5536

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 269

Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy
Richter, Daniel , Prokesch, Hannah, Graeff, Christian , Prall, Matthias, Simoniello, Palma , Fournier, Claudia , Bauer, Julia , Kaderka, Robert, Weymann, Alexander , Szabó, Gábor , Sonnenberg, Karin, Constantinescu, A., Johnson, Susan B., Misiri, Juna, Takami, Mitsuru , Miller, Robert C. , Herman, Michael , Asirvatham, Samuel J. , Jäkel, Oliver , Haberer, Thomas, Durante, Marco , Bert, Christoph , Packer, Douglas L. , Lehmann, H. Immo , Constantinescu, Anna M, Herman, Michael G., Brons, Stephan, Debus, Jürgen, Sonnenberg, Karin, Brons, Stephan , Debus, Jürgen , Bert, Christoph , Durante, Marco , Graeff, Christian , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | January 22, 2015 | Volume: 8 | Issue: 2 | Pages: 429-438

10.1161/circep.114.002436 Get It

Background— Particle therapy, with heavy ions such as carbon-12 ( 12 C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. Methods and Results— Intact hearts were explanted from 4 (30–40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and 12 C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of β + ( 11 C) activity were obtained. A 12 C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. Conclusions— This is the first report of the application of a 12 C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.
Electrophysiologic Characteristics of Ventricular Arrhythmias Arising From the Aortic Mitral Continuity – Potential Role of the Conduction System
Asirvatham, Samuel J. , authors, on behalf of the, authors, on behalf of the, Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | January 15, 2015 | Volume: 26 | Issue: 4 | Pages: No page available

10.1111/jce.12614 Get It

Pericardial Effusion Following Drain Removal after Percutaneous Epicardial Access for an Electrophysiology Procedure
Killu, Ammar M. , Wan, Siu‐Hin , Munger, Thomas M. , Hodge, David O. , Mulpuru, Siva K. , Packer, Douglas L. , Asirvatham, Samuel J. , Friedman, Paul A. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | January 13, 2015 | Volume: 38 | Issue: 3 | Pages: 383-390

10.1111/pace.12565 Get It

ObjectivesTo determine the frequency and predictors of pericardial effusion following epicardial sheath removal.BackgroundPericardial effusion can occur following cardiac surgical or interventional procedures including percutaneous epicardial access (EpiAcc), which is increasingly used as part of electrophysiology ablation procedures.MethodsA retrospective analysis of the Mayo Clinic comprehensive electronic medical record was performed from all patients who underwent planned EpiAcc as part of an electrophysiology ablation procedure between January 1, 2004 and June 30, 2013.ResultsOf 144 patients (mean age 51.3 ± 15.5 years, 68% male) who underwent planned EpiAcc as part of an electrophysiology ablation (95.8% pericardial access success rate), seven (4.9%) developed a postoperative pericardial effusion requiring repeat EpiAcc. Inferior access was utilized in 74 (51.4%) patients. Patients with pericardial effusion tended to be younger (41.1 years vs 51.8 years, P = 0.08) and were more likely to have undergone inferior approach access (85.7% vs 49.6%, P = 0.06) than those who did not develop postoperative pericardial effusion. Seventy‐one percent of patients with postoperative pericardial effusion versus 32.1% of patients without postoperative pericardial effusion had a preprocedure ejection fraction ≥55% (P = 0.03). There were no procedural‐related deaths, and no difference in mortality between groups.ConclusionsPostoperative pericardial effusion requiring repeat access/drainage was relatively infrequent, occurring in 4.9% of patients shortly after epicardial procedures. While the majority occur early and therefore require close observation, some patients may present in a delayed manner.
Percutaneous Epicardial Access for Mapping and Ablation Is Feasible in Patients With Prior Cardiac Surgery, Including Coronary Bypass Surgery
Killu, Ammar M. , Ebrille, Elisa , Asirvatham, Samuel J. , Munger, Thomas M. , Packer, Douglas L. , Friedman, Paul A. , Mulpuru, Siva K. , McLeod, Christopher J. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | January 10, 2015 | Volume: 8 | Issue: 1 | Pages: 94-101

10.1161/circep.114.002349 Get It

Background— Prior cardiac surgery, especially the presence of coronary artery bypass grafts, is thought to preclude percutaneous epicardial access (EpiAcc) and, therefore, mapping and ablation. We evaluated the feasibility and safety of EpiAcc in patients with a prior cardiac operation. Methods and Results— We retrospectively analyzed all patients who underwent EpiAcc for ablation for ventricular tachycardia or symptomatic premature ventricular complexes between 2004 and 2013 at Mayo Clinic, Rochester, MN. Of 162 patients who underwent EpiAcc, 18 had prior cardiac surgery (median age, 64 years, all men). This included 10 coronary artery bypass grafts, 2 epicardial implantable cardioverter defibrillator placement, 5 valve surgery, 2 septal myectomy, 1 aortic arch replacement, 1 myocardial bridge unroofing, and 1 myocardial perforation repair (3 patients had multiple procedures). Access was successful in 12 of 18; the inferior approach was used in 78%. Successful access was achieved in 6 of 10 patients with prior coronary artery bypass grafts. Adhesiolysis was required in 10 patients with the sheath, access wire, and pigtail or ablation catheter. Intraprocedural coronary angiography was performed in 8 patients. A total of 45 ventricular tachycardias/premature ventricular complexes were ablated. Thirteen patients underwent endocardial-only ablation, 2 had epicardial-only ablation, whereas 3 had endocardial–epicardial ablation. Ablation was deemed successful in 13 of 18 patients. Four patients had bleeding complications (pericardial effusion, pericardial hematoma, hemoperitoneum, and pericardial tamponade). In patients with coronary grafts, there was no evidence of acute graft disruption. Conclusions— Percutaneous EpiAcc is feasible in patients with previous cardiac surgery, including coronary artery bypass grafts. However, adhesiolysis is frequently required. Although the risk of coronary graft injury is low, life-threatening complications may occur.
Effects on Repolarization Using Dynamic QT Interval Monitoring in Long‐QT Patients Following Left Cardiac Sympathetic Denervation
Bos, J. Martijn , Bos, Katy M., Liang, Jackson J. , Patel, Nikhil A. , Hodge, David O. , Noheria, Amit , Asirvatham, Samuel J. , Ackerman, Michael J. , DeSimone, Christopher V. , Asirvatham, Samuel J , Bos, Johan M , Liang, Jackson

Journal of Cardiovascular Electrophysiology | January 5, 2015 | Volume: 26 | Issue: 4 | Pages: 434-439

10.1111/jce.12609 Get It

Dynamic QT Interval Monitoring Post‐LCSDBackgroundVideoscopic left cardiac sympathetic denervation (LCSD) is an adjunct therapy for reduction of arrhythmia‐induced events in patients with long‐QT syndrome (LQTS). LCSD reduces LQTS‐triggered breakthrough cardiac events. The temporal effects of QTc changes post‐LCSD have not been studied.MethodsWe utilized continuous QTc monitoring on 72 patients with LQTS. We evaluated acute and long‐term QTc changes in comparison to 12‐lead ECG‐derived QTc values prior to surgery, 24 hours postsurgery, and at follow up ≥3 months.ResultsSeventy‐two patients underwent LCSD at our institution (46% male, mean age at LCSD was 14 ± 10 years). The mean baseline, pre‐LCSD QTc was 505 ± 56 ms, which had decreased significantly at ≥3 months post‐LCSD to 491 ± 40 ms (P = 0.001). QTc monitoring revealed that the majority of the cohort (53/72; 74%) had a transient increase >30 ms in QTc from baseline, with an average maximum increase of 72 ± 30 ms. Resolution within 10 ms of baseline or less occurred in 57% (30/53) at 24 hours post‐LCSD.ConclusionsAlthough LQTS patients may have a paradoxically increased QTc post‐LCSD, the effects are transient in most patients. Importantly, no patients experienced any arrhythmias in the postoperative setting related to this transient rise in QTc.
Bypass Tracts Revisited
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | December 16, 2014 | Volume: 7 | Issue: 6 | Pages: 1268-1270

10.1161/circep.114.002475 Get It

Troubleshooting Implanted Cardioverter Defibrillator Sensing Problems I
Swerdlow, Charles D. , Asirvatham, Samuel J. , Ellenbogen, Kenneth A. , Friedman, Paul A. , Asirvatham, Samuel J , Ellenbogen, Kenneth A

Circulation: Arrhythmia and Electrophysiology | December 16, 2014 | Volume: 7 | Issue: 6 | Pages: 1237-1261

10.1161/circep.114.002344 Get It

The Challenges of Trigger Ablation for Ventricular Fibrillation
Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | December 2, 2014 | Volume: 26 | Issue: 1 | Pages: 116-117

10.1111/jce.12593 Get It

Electrophysiologic Characteristics of Ventricular Arrhythmias Arising from the Aortic Mitral Continuity—Potential Role of the Conduction System
Hai, Jo Jo , Chahal, C. Anwar A. , Friedman, Paul A. , Vaidya, Vaibhav R. , Syed, Faisal F. , Nanda, Sudip , Brady, Peter A. , Madhavan, Malini , Cha, Yong‐Mei , Mulpuru, Siva K. , Munger, Thomas M. , Packer, Douglas L. , Asirvatham, Samuel J. , DeSimone, Christopher V. , McLeod, Christopher J. , Asirvatham, Samuel J , Chahal, Choudhary Anwar A

Journal of Cardiovascular Electrophysiology | November 26, 2014 | Volume: 26 | Issue: 2 | Pages: 158-163

10.1111/jce.12587 Get It

Arrhythmogenic Substrate of Ventricular Arrhythmias at the AMCIntroductionCatheter ablation of ventricular arrhythmia (VA) at the fibrous aortic mitral continuity (AMC) has been described, yet the nature of the arrhythmogenic substrate remains unknown.MethodsProcedural records of 528 consecutive patients undergoing ablation of VA at Mayo Clinic, Rochester, MN, were reviewed. The electrocardiographic and electrophysiologic characteristics of patients with successful ablation at the AMC were analyzed to characterize the underlying arrhythmogenic substrate.ResultsOf the 21 patients (mean age 53.2 ± 13.4 years, 47.6% male) who underwent ablation of VA at the AMC with acute success, prepotentials (PPs) were found at the ablation sites preceding the ventricular electrogram (VEGM) during arrhythmias in 13 (61.9%) patients and during sinus rhythm in 7 (53.8%) patients. VAs with PPs were associated with a significantly higher burden of premature ventricular complexes (PVCs; 26.1 ± 10.9% vs. 14.9 ± 10.1%, P = 0.03), shorter VEGM to QRS intervals (9.0 ± 28.5 milliseconds vs. 33.1 ± 8.8 milliseconds, P = 0.03), lower pace map scores (8.7 ± 1.6 vs. 11.4 ± 0.8, P = 0.001), and a trend toward shorter V‐H intervals during VA (32.1 ± 38.6 milliseconds vs. 76.3 ± 11.1 milliseconds, P = 0.06) as compared to those without PP. A strong and positive correlation was found between V‐H interval and QRS duration during arrhythmia in those with PPs (B = 2.11, R2 = 0.97, t = 13.7, P < 0.001) but not in those without PPs.ConclusionLocal EGM characteristics and relative activation time of the His bundle suggest the possibility of conduction tissue as the origin for VA arising from the fibrous AMC. Specific identification and targeting of PPs when ablating VAs at this location may improve procedural success.
Ventricular Arrhythmia Risk Stratification in Patients With Tetralogy of Fallot at the Time of Pulmonary Valve Replacement
Sabaté-Rotés, Anna , Connolly, Heidi M. , Warnes, Carole A. , Ammash, Naser M., Phillips, Sabrina D. , Schaff, Hartzell V. , Burkhart, Harold M. , Hodge, David O. , Asirvatham, Samuel J. , Dearani, Joseph A. , McLeod, Christopher J. , Asirvatham, Samuel J , Schaff, Hartzell

Circulation: Arrhythmia and Electrophysiology | November 21, 2014 | Volume: 8 | Issue: 1 | Pages: 110-116

10.1161/circep.114.001975 Get It

Background— Most patients with repaired tetralogy of Fallot require pulmonary valve replacement (PVR), but the evaluation for and management of ventricular arrhythmia remain unclear. This study is aimed at clarifying the optimal approach to this potentially life-threatening issue at the time of PVR. Methods and Results— A retrospective analysis was performed on 205 patients with repaired tetralogy of Fallot undergoing PVR at our institution between 1988 and 2010. Median age was 32.9 (range, 25.6) years. Previous ventricular tachycardia occurred in 16 patients (8%) and 37 (16%) had left ventricular dysfunction, defined as left ventricular ejection fraction <50%. Surgical right ventricular outflow tract cryoablation was performed in 22 patients (10.7%). The primary outcome was a combined event including ventricular tachycardia, out-of-hospital cardiac arrest, appropriate implantable cardioverter defibrillator therapy, and sudden cardiac death. Freedom from the combined event at 5, 10, and 15 years was 95%, 90%, and 79%, respectively. In the first year after PVR, 2 events occurred. Conversely, in the 22 patients who underwent surgical cryoablation, a single event occurred 7 years after PVR. A history of ventricular tachycardia and left ventricular dysfunction was associated with higher risk for the combined event (hazard ratio, 4.7; P =0.004 and hazard ratio, 0.8; P =0.02, respectively). Conclusions— Patients with repaired tetralogy of Fallot undergoing PVR with history of ventricular tachycardia or left ventricular dysfunction appear to be associated with a higher risk of arrhythmic events after operation. Events in the first year after PVR are rare, and in select high-risk patients, surgical cryoablation does not seem to increase arrhythmic events and may be protective.