AbstractBackgroundRecipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement.MethodsAll patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all‐cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes.ResultsWe identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0‐18). During a mean follow‐up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all‐cause mortality (Hazard ratio, HR 1.10 [1.06‐1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07‐1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97‐1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy.ConclusionsCCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.
Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death
Background— The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with an ejection fraction (EF) ≤35% and clinical heart failure is well established. However, outcomes after replacement of the ICD generator in patients with recovery of EF to >35% and no previous therapies are not well characterized. Methods and Results— Between 2001 and 2011, generator replacement was performed at 2 tertiary medical centers in 253 patients (mean age, 68.3±12.7 years; 82% men) who had previously undergone ICD placement for primary prevention but subsequently never received appropriate ICD therapy. EF had recovered to >35% in 72 of 253 (28%) patients at generator replacement. During median (quartiles) follow-up of 3.3 (1.8–5.3) years after generator replacement, 68 of 253 (27%) experienced appropriate ICD therapy. Patients with EF ≤35% were more likely to experience ICD therapy compared with those with EF >35% (12% versus 5% per year; hazard ratio, 3.57; P =0.001). On multivariable analysis, low EF predicted appropriate ICD therapy after generator replacement (hazard ratio, 1.96 [1.35–2.87] per 10% decrement; P =0.001). Death occurred in 25% of patients 5 years after generator replacement. Mortality was similar in patients with EF ≤35% and >35% (7% versus 5% per year; hazard ratio, 1.10; P =0.68). Atrial fibrillation (3.24 [1.63–6.43]; P <0.001) and higher blood urea nitrogen (1.28 [1.14–1.45] per increase of 10 mg/dL; P <0.001) were associated with mortality. Conclusions— Although approximately one fourth of patients with a primary prevention ICD and no previous therapy have EF >35% at the time of generator replacement, these patients continue to be at significant risk for appropriate ICD therapy (5% per year). These data may inform decisions on ICD replacement.
Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement
Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.
Background Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period. Methods and Results Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG‐gated 100 μs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present. Conclusions Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27‐day survival period using this balloon‐based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.
Irreversible electroporation for the treatment of cardiac arrhythmias
AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.
Clinical introduction An asymptomatic 29-year-old woman presented for prenatal counselling. She had a history of a heart murmur since childhood and a previous echocardiogram suggesting ‘enlargement of the heart’. Physical exam revealed normal jugular venous pressure and contour. Precordial palpation was unremarkable. Auscultation, however, was abnormal; findings on inspiration and expiration are presented in Figure 1, sound clip. Question Based on the phonocardiogram and online supplementary audio clip, which of the following is correct? An early diastolic filling sound (S3) is heard, indicating increased right ventricular filling pressures. An ejection click without respiratory variation and a systolic ejection murmur are heard, consistent with bicuspid aortic valve stenosis. An ejection click with respiratory variation and a systolic ejection murmur are heard, consistent with pulmonic valve stenosis. A holosystolic murmur with inspiratory augmentation is heard, indicating tricuspid regurgitation.
The Inflammatory Hypothesis of Atrial Fibrillation: Diagnostic Marker, Therapeutic Target, or Innocent Bystander?