Mi-VAD - A Novel Supra-Valvular Cardiac Assist System Transitioning From Apical Cannulation
Kushwaha, S, Verkaik, Josiah, Khalpey, Zain, Joyce, Lyle D., Joyce, David, Yacoub, Magdi H., Griffiths, Leigh, Arunachalam, S., Antaki, James, Arunachalam, S P , Verkaik, Josiah E., Khalpey, Zain, Yacoub, Magdi Habib , Arunachalam, Shivaram P.

2026 Design of Medical Devices Conference | June 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2026-1073 Get It

Abstract Heart failure (HF) is a major cause of hospitalization and mortality worldwide. Ventricular assist devices (VADs) represent an alternative to cardiac transplantation for advanced HF. The main FDA-approved VAD (HeartMate III, Abbott), while effective, requires major cardiac surgery to insert the inflow cannula into the cardiac apex, and is associated with numerous co-morbidities and re-hospitalizations related to continuous flow and an external drive line and power supply. Mi-VAD, Inc. aspires to improve outcomes and quality of life with a miniature, minimally invasive, pulsatile, transcutaneously-powered VAD that is implanted above the aortic valve and/or the pulmonary valve and offering a wide range of hemodynamic support suitable for both advanced-stage and less advanced HF. Through its unique placement, there is the potential for right ventricular and biventricular cardiac assist for patients with restrictive cardiomyopathy and HFpEF for whom current VAD therapy is ineffective. Mi-VAD, Inc. has achieved proof of concept with its prototype, providing pulsatile ECG gated cardiac assist up to 10L/minute. Following initial bench top performance testing and in vivo efficacy and safety studies future work will focus on the development of wireless charging capability and conducting GLP builds for verification, regulatory clearance and commercialization. Additional technical development will focus on AI-driven hemodynamic optimization using multimodal physiologic sensing towards patient-specific digital twin of the Mi-VAD platform.
AI-Powered Ejection Fraction Estimation Through Cardiac Electromechanical Fingerprinting (CEMF): Feasibility Study
Wilson, Sancia Mary Jerold, LEE, JIEUN , Yerrapragada, Gayathri, Shariff, Mohammad Naveed, Shivaram, Srishiwin, Valluri, Sai Vibhav, Shivaram, Kriszwin, Sood, Divyanshi, IYER, VIVEK N, Kushwaha, S, Arunachalam, S., Arunachalam, S P , Yerrapragada, Gayathri, Shariff, Mohammed Naveed , Helgeson, Scott A. , Arunachalam, Shivaram P.

2026 Design of Medical Devices Conference | June 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2026-1044 Get It

Abstract Accurate assessment of left-ventricular ejection fraction (EF) is a critical metric in diagnosing and managing heart failure; however, methods of assessment remain resource intensive, not widely available in low-acuity or remote settings and are intermittent in nature. This study explores the potential of a novel framework, cardiac electromechanical fingerprinting (cEMF) using synchronized electrocardiography (ECG) and seismocardiography (SCG) collected from a wearable sensing patch as a low-cost, non-invasive, continuous estimate of EF that can be used for rapid point of care screening. A machine learning pipeline was developed to process raw ECG and SCG data to derive EF. Signals were cleaned using band-pass filtering, NeuroKit2-based ECG cleaning and fiducial detection of critical electromechanical events. We extracted an ECG-SCG feature space consisting of heart-rate variability metrics, ECG morphological characterization, SCG timing intervals, spectral and entropy-based features. The top thirty most important features for EF were used to train and evaluate several regressor models. The best performing model was the Gaussian Process Regressor with an MAE of 5.43. Our findings demonstrate the promise of producing clinically relevant cardiac function measures, such as EF, from wearable electromechanical signals. Future work using larger datasets and complementary physiological signals such as phonocardiogram (PCG) may significantly strengthen EF% estimation and other cardiac functions for clinical applicability.
B106-23 A Real-world Registry of Sotatercept in Pulmonary Arterial Hypertension: The Mayo Clinic Experience
Dubrock, H M, Valle, K T Del, Cajigas, H R, Anand, V, Kane, G C, Krowka, M J, Kushwaha, S, McCully, R B, Mielniczuk, L , Murphy, J G, Reddy, Y N V, Frantz, R P, DuBrock, Hilary M. , Cajigas, Héctor , Anand, Vidhu , Kane, Garvan C. , Krowka, Michael J. , McCully, Robert B. , Murphy, Joseph G. , Reddy, Yogesh N.V. , Frantz, Robert P.

American Journal of Respiratory and Critical Care Medicine | May 18, 2026 | Volume: 212 | Issue: Supplement_1 | Pages: No page available

10.1093/ajrccm/aamag162.5753 Get It

Abstract Rationale Sotatercept is a novel activin signaling inhibitor approved for the treatment of pulmonary arterial hypertension (PAH). Sotatercept has been studied in randomized clinical trials, but little is known regarding the real-world use of sotatercept. We sought to describe the safety, tolerability and efficacy of sotatercept in our clinical practice. Methods We performed a combined prospective and retrospective cohort study of all patients treated with sotatercept at Mayo Clinic Rochester since its approval in March 2024. Patients enrolled in a separate clinical trial of sotatercept were excluded from this analysis as their data will be reported separately. Clinical data was abstracted from the electronic health record. Follow-up data was collected at 6 ± 3 months after initiation of sotatercept. Data is summarized as n (%) and mean ± SD. We used paired t-tests to compare baseline and follow-up characteristics within individuals. Results Fifty-eight PAH patients treated with sotatercept were included. Patients were 48.4 ± 37.6 years old at treatment initiation and were predominantly female with a mean duration of PAH of 6.7 years and a range of PAH etiologies including portopulmonary hypertension, congenital heart disease, and pulmonary veno-occlusive disease (Table 1). Twenty-one (36%) of patients had mixed etiologies of PH. Six months after initiation of sotatercept, patients had a significant improvement in NTproBNP (1922 ± 4464 to 363 ± 596 pg/ml, p = 0.04), 6 minute walk distance (378.8 ±144.6 to 395.7±129.5 meters, p = 0.02) and right ventricular systolic pressure (74.6 ± 20.5 to 60.6 ± 20.3 mm Hg, p < 0.001). No patients permanently discontinued due to abnormal laboratory values. Mean highest hemoglobin achieved over the initial 6 months of treatment was 15.5 ± 2.1 g/dL and mean lowest platelet count was 181 ± 74K. Seven patients discontinued sotatercept at a range of 170-275 days after starting. Four patients discontinued due to possible treatment-related adverse effects: 1 each of gastrointestinal hemorrhage, retinal hemorrhage, hypoxia/intrapulmonary vasodilatation and spontaneous bilateral subdural hematomas. Three patients discontinued due to other reasons: newly diagnosed metastatic cancer leading to transition to hospice and two due to lack of improvement. Conclusions In this real-world registry of sotatercept in PAH, sotatercept was well-tolerated among patients with PAH and associated with improvements in exercise capacity, echocardiographic parameters, and NTproBNP. Overall discontinuation due to possible treatment-related adverse effects was low and reasons for discontinuation included bleeding and hypoxia attributed to intrapulmonary vasodilatation. This abstract is funded by: None