Back to Authors

Yerrapragada, Gayathri

Mayo Clinic

Jacksonville College

Citations 3

A Novel AI Powered Objective Pain Quantifying Software as a Medical Device
Shariff, Mohammad Naveed, LEE, JIEUN , Yerrapragada, Gayathri, Elangovan, Poonguzhali, Janarthanan, Jayarajasekaran, Richard, Samuel, Mitra, Dipankar , Sood, Divyanshi, Iyer, Vivek N., Arunachalam, S., Arunachalam, S P , Shariff, Mohammed Naveed , Yerrapragada, Gayathri, Elangovan, Poonguzhali , Natarajan, Thangeswaran, Helgeson, Scott A. , Arunachalam, Shivaram P.

2026 Design of Medical Devices Conference | June 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2026-1045 Get It

Abstract Pain assessment plays a critical role in clinical decision-making, yet conventional methods rely heavily on subjective self-reports such as the Visual Analog Scale (VAS) or the Numeric Rating Scale (NRS). These approaches fail in scenarios involving infants, sedated patients, unconscious individuals, or those with cognitive or communication impairments. To address this gap, this research proposes PainNet, an AI-driven, real-time facial pain recognition system that integrates deep learning-based object detection with Action Unit (AU)–based pain intensity scoring. The system uses YOLOv8 for rapid facial expression detection and incorporates Py-Feat to extract pain-relevant AUs, enabling computation of the Prkachin and Solomon Pain Intensity (PSPI) score. A balanced dataset comprising 500 images sourced from Delaware, BioVid, and RaFD was curated, annotated, and preprocessed for training. The YOLOv8-based binary pain vs. no-pain classifier achieved a mean Average Precision (mAP) of 0.89 and an F1-score of 0.80 on the test dataset, demonstrating strong performance in diverse environments and facial variations. The design emphasizes computational efficiency by activating AU analysis only when YOLOv8 detects probable pain, making PainNet suitable for continuous monitoring in ICUs, elder-care facilities, and telemedicine systems. This study demonstrates that the fusion of real-time object detection and clinically validated AU scoring can significantly advance automated, objective, and scalable pain assessment.
A Novel you only Listen once (YOLO) Deep Learning Model for Interstitial Lung Disease (ILD) Detection using Digital Lung Sound Auscultation: A Feasibility Study
LEE, JIEUN , Yerrapragada, Gayathri, Shariff, Mohammad Naveed, Ibrahim, Mohamed I. , Khalifa, H. Ezzat , Handral, Megha Sasidhar, Cherukuri, Swathi Priya , Kaur, Avneet , Sood, Divyanshi, IYER, VIVEK N, Arunachalam, S., Arunachalam, S P , Yerrapragada, Gayathri, Shariff, Mohammed Naveed , Helgeson, Scott A. , Arunachalam, Shivaram P.

2026 Design of Medical Devices Conference | June 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2026-1043 Get It

Abstract Interstitial lung disease (ILD) is a chronic, irreversible condition that is challenging to diagnose due to subtle symptoms and limitations of conventional tools. Noninvasive lung sound analysis using phonopulmography offers a promising alternative. This study evaluated the feasibility of a deep learning model for distinguishing normal and pathological lung sounds in ILD. Lung sound recordings were collected from 12 subjects (6 healthy, 6 ILD) and segmented beat-to-beat using simultaneously acquired ECG and phonopulmography, yielding 2,280 segments. Mel-frequency cepstral coefficients (MFCCs; 13 per segment) were extracted, and a one-dimensional CNN-based You Only Listen Once (YOLO) model was trained for segment classification. Evaluation used Leave-One-Out Cross-Validation, with patient-level classification by aggregating segment predictions via majority vote. On the test set (190 segments per class), the model achieved an average segment-level accuracy of 0.738 ± 0.087 and mean AUC of 0.850 ± 0.062. Precision, recall, and F1-score were 0.775 ± 0.148, 0.755 ± 0.183, and 0.738 ± 0.089, respectively. These preliminary results suggest that beat-level MFCCs with a 1D CNN-based YOLO model enable accurate segment- and patient-level classification. This feasibility study highlights the potential of AI-assisted auscultation for noninvasive monitoring and clinical decision support in ILD management, pending further validation in larger cohorts.
AI-Powered Ejection Fraction Estimation Through Cardiac Electromechanical Fingerprinting (CEMF): Feasibility Study
Wilson, Sancia Mary Jerold, LEE, JIEUN , Yerrapragada, Gayathri, Shariff, Mohammad Naveed, Shivaram, Srishiwin, Valluri, Sai Vibhav, Shivaram, Kriszwin, Sood, Divyanshi, IYER, VIVEK N, Kushwaha, S, Arunachalam, S., Arunachalam, S P , Yerrapragada, Gayathri, Shariff, Mohammed Naveed , Helgeson, Scott A. , Arunachalam, Shivaram P.

2026 Design of Medical Devices Conference | June 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2026-1044 Get It

Abstract Accurate assessment of left-ventricular ejection fraction (EF) is a critical metric in diagnosing and managing heart failure; however, methods of assessment remain resource intensive, not widely available in low-acuity or remote settings and are intermittent in nature. This study explores the potential of a novel framework, cardiac electromechanical fingerprinting (cEMF) using synchronized electrocardiography (ECG) and seismocardiography (SCG) collected from a wearable sensing patch as a low-cost, non-invasive, continuous estimate of EF that can be used for rapid point of care screening. A machine learning pipeline was developed to process raw ECG and SCG data to derive EF. Signals were cleaned using band-pass filtering, NeuroKit2-based ECG cleaning and fiducial detection of critical electromechanical events. We extracted an ECG-SCG feature space consisting of heart-rate variability metrics, ECG morphological characterization, SCG timing intervals, spectral and entropy-based features. The top thirty most important features for EF were used to train and evaluate several regressor models. The best performing model was the Gaussian Process Regressor with an MAE of 5.43. Our findings demonstrate the promise of producing clinically relevant cardiac function measures, such as EF, from wearable electromechanical signals. Future work using larger datasets and complementary physiological signals such as phonocardiogram (PCG) may significantly strengthen EF% estimation and other cardiac functions for clinical applicability.