ABSTRACT Background Anemia is an established marker of cardiovascular disease severity and risk which leads to elevations in resting myocardial blood flow (MBF) and impaired myocardial flow reserve (MFR) in patients without obstructive coronary artery disease (CAD). Anemia can potentially be detected opportunistically from blood pool density changes on computed tomography (CT) imaging. Objectives We evaluated relationships between chamber density measurements with hemoglobin, positron emission tomography (PET) findings, and cardiovascular events. Methods We included 33460 patients from 13 sites in the REFINE-PET who underwent PET and 24368 patients undergoing lung cancer screening chest CT. A deep learning model segmented cardiac chambers from CT images, then quantified chamber density. We evaluated the relationship between chamber density measures with resting MBF and MFR, as well as associations with death or myocardial infarction (MI). Results We included a total of 57,828 patients. A higher density in myocardium compared to left ventricle blood pool was associated with reduced MFR (adjusted odds ratio 3.02 per SD increase, 95% confidence interval[CI] 2.72 – 3.38) and an increased risk of death or MI in (adjusted hazard ratio[HR] 1.38 per SD increase, 95% CI 1.26-1.51). Having myocardial density higher than blood pool density was also associated with cardiovascular death in patients undergoing low-dose chest CT (adjusted HR 1.73, 95% CI 1.20-2.52). Conclusions In a large multimodality dataset, lower cardiac chamber density is associated with impaired MFR and independently associated with cardiovascular events. These biomarkers can be automatically extracted from CT to provide physiologic insights and potentially guide patient care. CONDENSED ABSTRACT Anemia is an important marker of cardiovascular disease severity and predictor of cardiovascular events. We utilized deep learning to measure cardiac chamber density on computed tomography imaging as a surrogate for anemia in 57,828 patients from two large multicenter studies. A higher density in myocardium compared to left ventricle blood pool was associated with reduced MFR and an increased risk of death or MI in patients undergoing positron emission tomography, and an increased risk of cardiovascular death in patients undergoing low-dose computed tomography. These biomarkers can provide additionally physiologic insights which could be used to guide patient care.
CT Attenuation Map–Derived Body Composition Is Associated with Cardiorespiratory Fitness in Multicenter External Validation
ABSTRACT Aims Exercise capacity is a powerful predictor of cardiovascular risk. In patients unable to exercise, body composition analysis can potentially be used to estimate cardiorespiratory fitness. We developed a body composition “fitness” score, then validated its utility in two external populations. Methods and Results We included patients from four sites undergoing single photon emission computed tomography (SPECT) and twelve sites undergoing positron emission tomography (PET). We quantified body composition using deep learning. We evaluated associations between body composition and good exercise capacity (defined as completing ≥7 minutes on a Bruce protocol) then developed a body composition “fitness” score. We then assessed the associations of “fitness” score with exercise capacity and all-cause mortality in external populations. In total, 36471 patients were included with median age 67 (interquartile range 58 – 74). Median skeletal muscle density was higher among patients with good exercise capacity. In the external SPECT population, the body composition “fitness” score had higher prediction performance for good exercise capacity (AUC 0.771, 95% CI 0.752 – 0.789) than age (AUC 0.717, p<0.01). In the external PET population, high body composition “fitness” score was associated with lower cardiovascular death (adjusted hazard ratio 0.70, 95% CI 0.62 – 0.79, p<0.001). Conclusions We demonstrated that a comprehensive body composition “fitness” score could identify patients with good cardiorespiratory fitness. This approach transforms routinely acquired CT data into a surrogate marker of fitness which can be applied in patients undergoing PET, or other CT imaging, where exercise testing is not performed. Graphical Abstract Overview of study design. The overall population (n=36471) was split as outlined above. Body composition was analyzed from available computed tomography imaging. The distribution of body composition measures were analyzed in the combined single photon emission computed tomography (SPECT) populations. A body composition “fitness” score was derived to predict good exercise capacity in the internal population, with associations assessed in the two external testing populations.