Back to Authors

Varas-rodriguez, Emil

Mayo Clinic

Mayo Clinic

Citations 4

EP279 Intraoperative Methadone vs Regional and Local Anesthesia in Periacetabular Osteotomy with Hip Arthroscopy: Postoperative Pain, Opioid Use, and Length of Surgery in Three Cohorts
Jackson, Adam, Varas-rodriguez, Emil, Havesi, Mario, Handlogten, Katie, Grigoriou, Emmanouil, Varas‐Rodríguez, Emil , Sierra, Rafael J. , Katie, Handlogten, Grigoriou, Emmanouil

Journal of Hip Preservation Surgery | December 22, 2025 | Volume: 12 | Issue: Supplement_2 | Pages: ii116-ii116

10.1093/jhps/hnaf069.376 Get It

Abstract Introduction Periacetabular osteotomy (PAO) is a complex reconstructive procedure performed to address acetabular dysplasia. Postoperative pain management is challenging due to surgical invasiveness and the need to limit opioid use. Regional and local anesthesia are commonly used but may be short-lived, increasing opioid requirements. However, methadone is a long-acting analgesic that may offset these limitations. This is the first study to evaluate methadone use in PAO with arthroscopy, comparing efficacy and opioid consumption of three different anesthetic regimens: (1) lumbar plexus catheter with a single shot intrathecal hydromorphone (LP+HM) (2) locally administered intraoperative soft tissue periarticular injection with ropivacaine, epinephrine, and ketorolac (arthroplasty block [AP]), and (3) AP with intraoperative methadone (AP+M). Methods We retrospectively reviewed PAO with arthroscopy cases from 2022 to 2025 at a single tertiary center. All cases were performed by the same surgeon and anesthesia team and managed on the same postoperative floor. Patients were categorized into three groups: (1) LP+HM, (2) AP, and (3) AP+M. Primary outcomes were 48-hour morphine milligram equivalents (MME) and total inpatient opioid consumption. Length of stay (LoS), operative time, VAS pain scores at 24h and 48h, and antiemetic use were also collected. Results Fifty PAO procedures were identified. The mean age was 16.0±2.3 years, 96% were female, and mean BMI was 22.8±4.4 kg/m2. No significant differences were seen between groups. The addition of methadone to the arthroplasty block regimen (AP+M) resulted in significantly lower 48-h MME compared to AP alone (55.9 mg vs 83.3 mg, p=0.030), but did not differ significantly from LP+HM (39.0mg, p=0.593). Total inpatient opioid consumption was also significantly reduced in the AP+M (69.3 mg) and LP+HM (66.7 mg) groups compared to AP (110.5 mg, p=0.012). Similarly, 24-hour pain scores were significantly lower in the AP+M (3.6±1.9) and LP+HM (3.7±2.1) groups compared to AP (6.4±1.6, p=0.041). Length of stay was comparable across groups (p=0.39). Conclusion Intraoperative methadone added to the arthroplasty block provided comparable analgesia and reduced total opioid use compared to arthroplasty block alone. These findings support methadone as an adjunct to periarticular anesthesia for improving pain control and reducing opioid use in hip preservation surgery.
EP219 Total Hip Arthroplasty in Skeletally Immature Patients: Updated Mid-Term Outcomes in Patients with an Open Triradiate Cartilage
Reuter, Zachary C. , Varas-rodriguez, Emil, Hevesi, Mario, Grigoriou, Emmanouil, Selemon, Nicolas A. , Varas‐Rodríguez, Emil , Hevesi, Mario , Sierra, Rafael J. , Grigoriou, Emmanouil

Journal of Hip Preservation Surgery | December 22, 2025 | Volume: 12 | Issue: Supplement_2 | Pages: ii101-ii101

10.1093/jhps/hnaf069.325 Get It

Abstract Introduction The utilization of total hip arthroplasty (THA) in skeletally immature patients remains controversial, with an open triradiate cartilage traditionally perceived as a relative contraindication due to concerns of acetabular fixation and component loosening. Early evidence suggests that THA may be a feasible option in this patient population yielding favorable short-term outcomes, however larger series and mid-term data are lacking. This study presents the largest series of THA in patients with open triradiate cartilage to date with mid-term clinical, radiographic, and patient-reported outcomes. Methods A retrospective review of our institutional Total Joint Registry identified 19 patients (22 hips) who underwent THA while having an open triradiate cartilage growth plate between the year 2000 and 2024. Skeletal maturity was assessed utilizing the modified Oxford bone age and all patients had a score of “1” or “2” on the triradiate cartilage stage of maturation. Demographics, surgical characteristics, implant data, radiographic parameters, and clinical outcomes were collected. Functional hip scores were assessed via the Harris Hip Score (HHS). Kaplan-Meier analysis was performed to analyze reoperation rates. Results The average age at surgery was 14 years (SD=1.68), the average BMI was 24 (SD=7.1) and 64% were male. Mean follow-up was 6.05 years (range 1-15). The mean modified Oxford bone age for this cohort was 23 (SD=1.4). The most common indications for THA were avascular necrosis (64%), degenerative joint disease (27%), and neoplasia (9%). Preoperatively, 54.5% of patients utilized gait aids. Postoperatively, all patients reported independent ambulation without assistive devices with an average HHS of 91.65 (SD=11.42). Ninety-six percent of implants were stable at final radiographic follow up. Both reported complications involved acetabular cup loosening, requiring revision of the acetabular component. Conclusion This study presents the largest cohort in the literature of patients who underwent THA with open triradiate cartilage. Our results highlight high patient reported outcomes and low revision rates at mid-term follow up. All patients had excellent implant fixation without radiographic signs of loosening at final radiographic follow up. These results support the use of THA in skeletally immature patients without the need to delay THA for closure of the triradiate cartilage.
FP2.6 Guardian Table Extension in Periacetabular Osteotomy: A Risk Factor for Intraoperative Posterior Column Fracture
Tai, David, Varas-rodriguez, Emil, Restrepo, Diego J, Grigoriou, Emmanouil, Reuter, Zachary C. , Varas‐Rodríguez, Emil , Perez, Sergio F. Guarin , Restrepo, Diego J. , Grigoriou, Emmanouil , Sierra, Rafael J.

Journal of Hip Preservation Surgery | December 22, 2025 | Volume: 12 | Issue: Supplement_2 | Pages: ii4-ii5

10.1093/jhps/hnaf069.012 Get It

Abstract Introduction Periacetabular osteotomy (PAO) is a well-established procedure for hip preservation, traditionally performed on conventional radiolucent tables that provide rigid support to the lower extremity. The Pivot Guardian™ Distraction System extension was recently introduced to facilitate concomitant hip arthroscopy and PAO, enhancing surgical efficiency. However, flexible leg support may alter the biomechanical stability of the pelvis during osteotomy cuts, particularly the ischial osteotomy. This study compared intraoperative and perioperative outcomes of PAOs performed with the Guardian Table extension to those performed on conventional radiolucent tables. Methods All PAOs performed by one surgeon since the introduction of the guardian extension were reviewed. Seventy-two PAO cases were identified; 26 were performed on a Guardian table concomitantly with arthroscopic procedures, while 46 were performed on a conventional radiolucent Demographic variables, surgical characteristics, intraoperative complications and perioperative outcomes were compared between the groups. Groups were comparable in age, BMI, smoking status, history of previous hip arthroscopy, and primary diagnoses. Results The use of the Guardian extension had a higher proportion of women (96.2% vs. 73.9%, p=0.018) and longer operative times due to the addition of the hip arthroscopy (170 ± 54 vs. 90 ± 18 min, p < 0.0001). Notably, intraoperative posterior column fractures only occurred with the use of the Guardian table (15.4% vs. 0%, p=0.0062). No other identifiable risk factors contributed to this finding. Fractures were diagnosed based on intraoperative fluoroscopic images, or immediate postop X-rays, or X-rays at the first follow up. Rates of other complications were similar between the two groups. Conclusion While the Guardian Table extension facilitates simultaneous arthroscopic procedures in the context of PAO procedures, its use was associated with an increased risk of intraoperative posterior column fractures. This may be due to the flexible structure of the leg extension component. Surgeons should be aware of the flexible nature of the table and plan for intraoperative stabilization of the distal portion to increase rigidity.
Three-dimensional biomechanical analysis of flexible intramedullary nailing constructs in length-unstable pediatric femur fractures
Grigoriou, Emmanouil , Transtrum, M. Bryant , Deshpande, Ameya H., Doak, Jeremy P., Ehrensberger, Mark T. , Varas-rodriguez, Emil, Varas‐Rodríguez, Emil , Deshpande, Ameya H.

Journal of Pediatric Orthopaedics B | June 18, 2025 | Volume: 34 | Issue: 6 | Pages: 579-587

10.1097/bpb.0000000000001267 Get It

Flexible intramedullary nail fixation of pediatric femoral shaft fractures offers advantages such as shorter hospital stays, faster return to function, and less associated costs when compared with traction and casting. This study compared the biomechanical performance of three configurations: 2CS, 2CL, and 3CL. Thirty synthetic femur models with identical, length-unstable, spiral fractures were tested using a three-dimensional camera system to assess real-time micromotion. Three groups were analyzed: (a) 2CS – two 3.5 mm C- and S-shaped nails inserted anterograde, (b) 2CL – one ‘C’ and one ‘S’ shaped 3.5 mm titanium nail-inserted retrograde from a single lateral entry, (c) 3CL – two ‘C’ shaped 3.5 mm titanium nails inserted medially and laterally with a third ‘C’ shaped 2.5 mm nail placed retrograde from an anterolateral site. Torsional loading, cyclical loading, and load-to-failure tests were conducted. The 3CL configuration demonstrated superior biomechanical performance. It exhibited the highest torsional stiffness [0.67 ± 0.06 Nm/° for external rotation (ER), 0.404 = ± 0.06 Nm/° for internal rotation (IR); P = 0.002], least displacement (0.05 ± 0.02 vs. 0.30 ± 0.02 mm for 2CL and 0.57 ± 0.05 mm for 2CS; P = 0.012), and required the highest load-to-failure (162 ± 83 vs. 1064 ± 75 N for 2CL and 790 ± 34 N for 2CS; P = 0.016).The 3CL configuration provided superior strength and stability across all tests, supporting its role in the fixation of length-unstable pediatric femoral fractures.