Back to Authors

Hamandi, A

Mayo Clinic

Mayo Clinic in Arizona

Citations 1

(324) Changes in Inflatable Penile Prosthesis Size Following Revision Procedures
Hamandi, A, Hashemi, Milad Bonakdar , Guillén-Lozoya, A.H. , Helo, S, Ziegelmann, M, Kohler, T, Hamandi, Ali, Ziegelmann, M

The Journal of Sexual Medicine | December 9, 2025 | Volume: 22 | Issue: Supplement_4 | Pages: No page available

10.1093/jsxmed/qdaf320.320 Get It

Abstract Introduction Inflatable Penile Prostheses (IPPs) are a surgical implant used to treat erectile dysfunction in patients who do not respond to clinical treatments. IPP cylinder size often changes with cylinder exchange upon revision, but trends in these changes have not been formally assessed in the existing literature. Objective To analyze patient data for changes in implant size upon first revision. Methods Data included patients who underwent IPP surgical revision at Mayo Clinic Rochester between January 2021 and May 2024. Inclusion criteria specified cylinder exchange upon first revision of the IPP. A total of 48 patients were included in the analysis. A Bayesian regression was used to estimate the posterior probability of an increase in cylinder size upon first revision, after adjusting for patient age, revision service provider, and duration between implant and revision as covariates. Linear regression was used to assess the relationship between the extent of cylinder size increase and duration before revision. Results The median increase in cylinder size is 2 cm for the left cylinder and 1.75 cm for the right cylinder. The median increase for each patient’s average cylinder size is 1.625 cm. The median percentage increase in cylinder size is 9.76% for the left cylinder and 8.11% for the right cylinder. The median percentage increase for each patient’s average cylinder size is 8.13%. Posterior probabilities of increase were significant for the left cylinder, right cylinder, and the average cylinder size (Left PP: 97.53%; Right PP: 98.05%; Average PP: 98.05%). The extent of cylinder size increase is not significantly associated with duration before revision (Left p-value = 0.476; Right p-value = 0.500). Conclusions Patients and surgeons can expect about a 10% increase in cylinder size with their first revision. However, the extent of increase is not significantly associated with the duration between implant date and first revision. Future research efforts should focus on identifying where exactly this additional size is generated and what extent of size increase amounts to a noticeable difference for patients. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Coloplast