Background: In recent years, the prevalence of medial ulnar collateral ligament injuries has increased in throwers of all ages and skill levels. The motusBASEBALL sensor possesses an inertial measurement unit (IMU) that has been developed and applied to the throwing arm to allow for measurements of several objective parameters, which may prove beneficial for monitoring, rehabilitation, and injury prevention in the throwing athlete. However, the reliability, consistency, and validity of the IMU have not been independently assessed. Purpose: To evaluate the reliability, consistency, and validity of the motusBASEBALL sensor compared with the historic gold standard of marker-based motion capture. Study Design: Controlled laboratory study. Methods: A total of 10 healthy male baseball athletes with varsity-level high school experience volunteered to participate in this study. Participants were fitted with 37 retroreflective markers for motion capture and the motusBASEBALL IMU sensor. Participants threw 5 fastballs at maximum effort, with measurements recorded simultaneously by motion capture and the IMU. Arm slot, arm speed, arm stress, and shoulder rotation were measured and compared. Results: Of the 4 metrics generated by the IMU, significant differences were found for 3 of the throwing metrics compared with motion capture including arm slot (5.0°± 6.1°; P = .037), elbow varus torque (9.4 ± 12.0 N·m; P = .037), and shoulder rotation (6.3°± 6.1°; P = .014). Arm speed did not demonstrate a statistically significant difference (29.2 ± 96.8 rpm; P = .375). The IMU consistently underreported pitching performance values. Shoulder rotation exhibited excellent reliability with <5° of error, and arm slot demonstrated good reliability with <10° of error. Arm stress and arm speed were less reliable. Conclusion: The IMU was not accurate or valid for arm slot, arm stress, and shoulder rotation compared with marker-based motion capture. It was relatively accurate for arm speed. Despite its lack of validity, it was consistent and reliable for arm speed and shoulder rotation and relatively reliable for arm slot and arm stress. Caution should be used when comparing values provided by this IMU to the gold standard of marker-based motion capture. Clinical Relevance: IMU technology has potential to be used in monitoring, rehabilitation, and injury prevention in throwing athletes if valid. This study demonstrates that the values provided by the IMU should not be considered equivalent to those generated by the gold standard of marker-based motion capture; however, there may still be a role for this technology when relying on its internal consistency for intrathrower comparisons and tracking.
Fluorescent Microspheres Injected into Skeletal Muscle to Observe Fluid Movement in Interstitial Space
The force within a muscle may be assessed using intramuscular pressure measurements (IMP). However, a limiting factor in implementing this technology in the clinic is the observed variability of IMP measurements. The variability may be due in part to the flow of interstitial fluid. The objective of this study was to develop a technique for tracking interstitial fluid flow during muscle lengthening using fluorescent microspheres. Additionally, the effect of microsphere diameter on dispersion was evaluated. Fluorescent microspheres were injected into the rat tibialis anterior (TA) either before (right limb) or after (left limb) lengthening to 10% strain (n = 5). To help discriminate the effects of microsphere size, 10 µl of microspheres (0.25% by volume) were injected simultaneously: 0.1 µm in sky blue and 0.2 µm in yellow green. Once frozen, 20 µm muscle cross‐sections were stained and imaged using confocal microscopy to evaluate the microsphere's axial dispersion as a percent of muscle length. The microsphere dispersion was normalized to the muscle length. The fluorescent microspheres flowed with the interstitial fluid and did not penetrate the muscle fiber. There was significantly greater microsphere dispersion with passive strain (p‐value > 0.01) for lengthened samples (31±7%) compared to static samples (17±9%). Dispersion did not differ for the two bead sizes. In conclusion, this illustrates the microspheres track the interstitial fluid and passive lengthening results in additional dispersion. Supported by NIH under award number R01HD31476 and T32HL105355.
Agreement between the Skull Vibration-Induced Nystagmus Test and Semicircular Canal and Otolith Asymmetry
Abstract Background How significant asymmetries in otolith organ function in the presence of symmetrical and asymmetrical semicircular canal function influence skull vibration-induced nystagmus testing (SVINT) has not been well described. Purpose The aim of the study is to examine the agreement between SVINT and caloric testing, ocular vestibular-evoked myogenic potentials (oVEMP), and cervical vestibular-evoked myogenic potentials (cVEMP) for detecting asymmetric vestibular function. Research Design This is a retrospective study of patients presenting with the chief complaint of vertigo, dizziness, or imbalance. Study Sample A total of 812 patients were studied with a median age at testing of 59 years (interquartile range 46‐70; range 18‐93) and included 475 (59%) women. Intervention Either the monothermal warm caloric test or alternate binaural bithermal caloric test, oVEMP, and cVEMP tests were administered to all patients. All patients underwent the SVINT prior to vestibular laboratory testing. Data Collection and Analysis Agreement between tests categorized as normal versus abnormal was summarized using percent concordance (PC). Sensitivity and specificity values were calculated for SVINT compared with other tests of vestibular function. Results There was higher agreement between ipsilateral and contralateral SVINT with the caloric test (PC = 80% and 81%, respectively) compared with oVEMP (PC = 63% and 64%, respectively) and cVEMP (PC = 76% and 78%, respectively). Ipsilateral and contralateral SVINT showed higher sensitivity for the caloric test (sensitivity = 47% and 36%, respectively) compared with oVEMP (sensitivity = 26% and 21%, respectively), or cVEMP (sensitivity = 33% vs. 27%, respectively). Specificity of SVINT was high (>80%) for all assessments of vestibular function. Conclusion The presence of SVIN is a useful indicator of the asymmetry of vestibular function between the two ears when making judgments about semicircular canal asymmetry but is less sensitive to asymmetries in otolith organ function.
Randomized, Controlled Trial of a Novel Rodent-Based Subarachnoid Hemorrhage Simulation System Using Advanced Biometric Analysis
Journal of Neurological Surgery Part B: Skull Base | April 8, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available
Journal of Neurological Surgery Part B: Skull Base | February 5, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available
Background Low back pain (LBP) is common among individuals with transfemoral amputation (TFA) and has a negative impact on quality of life. Little is known about health care utilization for LBP in this population and whether utilization varies by amputation etiology. Objective To determine if individuals with TFA have an increased likelihood of seeking care or reporting symptoms of acute or chronic LBP during physician visits after amputation compared with matched individuals without amputation. Design Retrospective cohort. Setting Olmsted County, Minnesota (2010 population: 144 248). Participants All individuals with incident TFA (N = 96), knee disarticulation, and transfemoral amputation residing in Olmsted County between 1987 and 2014. Each was matched (1:10 ratio) with non‐TFA adults on age, sex, and duration of residency. Individuals were divided by etiology of amputation: dysvascular and trauma/cancer. Interventions Not applicable. Main Outcome Measurements Death and presentation for evaluation of LBP (LBP event) while residing in Olmsted County. LBP events were identified using validated International Classification of Diseases, Ninth Revision (ICD‐9) codes and corresponding Berkson, Hospital International Classification of Diseases Adapted (HICDA), and ICD‐10 diagnostic codes. Hurdle and competing‐risk Cox proportional hazard models were used. Results Having a TFA of either etiology did appear to correlate with increased frequency of LBP events, although this association was only statistically significant within the dysvascular TFA cohort (dysvascular TFA cohort: relative risk [RR] 1.80, 95% confidence interval [CI] 1.07‐3.03, median follow‐up 0.78 years; trauma/cancer TFA cohort: RR 1.14, 95% CI 0.58‐2.22, median follow‐up 7.95 years). In time to event analysis, dysvascular TFA had an increased risk of death and event. Obesity did not significantly correlate with increased frequency of LBP events or time to event for either cohort. At any given point in time, individuals with TFA of either etiology who had phantom limb pain were 90% more likely to have an LBP event (hazard ratio [HR] 1.91, 95% CI 1.11‐3.31). Conditional on not dying and no LBP event within the first 2.5 years, individuals with prosthesis had a decreased risk of LBP events in subsequent years. Conclusions Risk of LBP events appears to vary by TFA etiology. Obesity did not correlate significantly with increased frequency of LBP event or time to event. Phantom limb pain correlated with decreased time to LBP event after amputation. The association between prosthesis receipt and LBP events is ambiguous. Level of Evidence III.
CORR Insights®: Do Spatiotemporal Gait Parameters Improve After Pilon Fracture in Patients Who Use the Intrepid Dynamic Exoskeletal Orthosis?
Clinical treatments of skeletal muscle weakness are hindered by a lack of an approach to evaluate individual muscle force. Intramuscular pressure (IMP) has shown a correlation to muscle force in vivo, but patient to patient and muscle to muscle variability results in difficulty of utilizing IMP to estimate muscle force. The goal of this work was to develop a finite element model of whole skeletal muscle that can predict IMP under passive and active conditions to further investigate the mechanisms of IMP variability. A previously validated hypervisco-poroelastic constitutive approach was modified to incorporate muscle activation through an inhomogeneous geometry. Model parameters were optimized to fit model stress to experimental data, and the resulting model fluid pressurization data were utilized for validation. Model fitting was excellent (root-mean-square error or RMSE <1.5 kPa for passive and active conditions), and IMP predictive capability was strong for both passive (RMSE 3.5 mmHg) and active (RMSE 10 mmHg at in vivo lengths) conditions. Additionally, model fluid pressure was affected by length under isometric conditions, as increases in stretch yielded decreases in fluid pressurization following a contraction, resulting from counteracting Poisson effects. Model pressure also varied spatially, with the highest gradients located near aponeuroses. These findings may explain variability of in vivo IMP measurements in the clinic, and thus help reduce this variability in future studies. Further development of this model to include isotonic contractions and muscle weakness would greatly benefit this work.
Clinically Relevant Outcome Measures Following Limb Osseointegration; Systematic Review of the Literature
Objectives: The current standard of care for an amputee is a socket-based prostheses. An osseointegrated implant (OI) is an alternative for prosthetic attachment. Osseointegration addresses reported problems related to wearing a socket interface, such as skin issues, discomfort, diminished function, quality of life, prosthetic use, and abandonment. The purpose of this report is to systematically review current literature regarding OI to identify and categorize the reported clinically relevant outcome measures, rate the quality of available evidence, and synthesize the findings. Data sources: A multidisciplinary team used PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) methods. Search methodology was based on identifying clinically relevant articles. Three databases were searched: PubMed, CINAHL, and Web of Science. Study Selection: Clinical studies with aggregated data reporting at least 1 clinically relevant outcome measure were included. Data Extraction: The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criterion was used for critical appraisal and recommendations. Conclusions: This review identified 21 clinically relevant observational studies. Outcome measures were categorized into the following 9 categories: vibratory stimulation, complications, biomechanics, economics, patient-reported outcome measures, electromyography, x-ray, physical functional performance, and energy consumption. This systematic review consisted of Level III and IV observational studies. Homogeneous outcome measures with strong psychometric properties across prospective studies do not exist to date. Higher-level, prospective, randomized, long-term, clinically relevant trials are needed to prove efficacy of OI compared with socket prosthetic attachment. Osseointegration was at least equivalent to sockets in most studies. In some cases, it was superior. Osseointegration represents a promising alternative to socket prosthetic attachments for extremity amputees. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
The Effect of Ankle Disk Training on Muscle Reaction Time in Subjects with a History of Ankle Sprain
The purpose of this study was to determine whether 8 weeks of ankle disk training alters ankle muscle onset latency of patients with a history of lateral ankle sprain. The training was completed by eight minimally symptomatic subjects with a history of nonrehabilitated, unilateral, inversion ankle sprain sustained between 6 and 16 months before entry into the study. Ankle inversion perturbations monitored by fine-wire electromyography were performed in four lower extremity muscles (anterior tibialis, posterior tibialis, peroneus longus, and flexor digitorum longus) of all subjects on both the injured (experimental) and noninjured (control) legs. Testing was performed at study entry and after 8 weeks of ankle disk training on the previously injured ankle. Results revealed a statistically significant decrease in the anterior tibialis onset latency in both the experimental (67.6 ± 20.3 to 51.7 ± 17.6) and control (65.5 ± 9.8 to 53.8 ± 23.7) ankles after the training period. These findings indicate that muscle onset latency decreases in specific ankle muscle groups after ankle disk training in previously injured ankles. Both the experimental and control ankles demonstrated a significant change, which raises the question as to whether a proprioceptive cross-training effect occurred.